121 E602332 “XR-axi s error: Failed t o start.” [Cause] Failed to start the X R-axis operation. T here is the pos sibility of abnormal s tatus in the X MP board. [Treatm ent] Please turn on the power supply of the m achi…

100%1 / 1361
120
E602531 “Axis Driver: YR-axis status error.”
[Cause]
The axis move was blocked during or at the start of the operation.
An initialization error, servo error or alarm may have been generated for the axis.
This error can also be displayed against errors for other axes.
Or, the XMP board may have failed.
[Treatment]
Press the emergency stop switch, and then return the axes to the home position again.
If the error persists, exit the system and contact our service engineer or the agency.
E602117 “X-axis error: Cannot operate because of the feeder float sensor's
detection.
[Cause]
Indicates that the feeder float sensor detects something during the X-axis operation.
[Treatment]
Eliminate the cause to which the feeder float sensor is reacting.
E602217 “Y-axis error: Cannot operate because of the feeder float sensor's
detection.
[Cause]
Indicates that the feeder float sensor detects something during the Y-axis operation.
[Treatment]
Eliminate the cause to which the feeder float sensor is reacting.
E602317 “XR-axis error: Cannot operate because the feeder float sensor's
detection.
[Cause]
Indicates that the feeder float sensor detects something during the XR-axis operation.
[Treatment]
Eliminate the cause to which the feeder float sensor is reacting.
E602418 “Yc-axis error: Cannot operate because of the board sensor's
detection.
[Cause]
Indicates that the board sensor detects something during the Yc-axis operation.
[Treatment]
Eliminate the causes to which the board sensor is reacting.
E602132 “X-axis error: Failed to start.”
[Cause]
Failed to start X-axis operation. There is the possibility of abnormal status in the XMP board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E602232 “Y-axis error: Failed to start.”
[Cause]
Failed to start Y-axis operation. There is the possibility of abnormal status in the XMP board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
121
E602332 “XR-axis error: Failed to start.”
[Cause]
Failed to start the XR-axis operation. There is the possibility of abnormal status in the XMP
board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E602432 “Yc-axis error: Failed to start.”
[Cause]
Failed to start the Yc-axis operation. There is the possibility of abnormal status in the XMP board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E602532 “YR-axis error: Failed to start.”
[Cause]
Failed to start the YR-axis operation. There is the possibility of abnormal status in the XMP
board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E602536 “Axis Driver: YR-axis. The velocity error exceeded the limit. (Check
the power supply for the possibilities of low power supply voltage.)”
[Cause]
An error occurred in the servo system.
Fluctuations in the driving power may have prevented the proper operation of the system.
[Treatment]
Check the conditions of the machine power source.
E602133 “X-axis error: Failed to stop.”
[Cause]
Failed to stop X-axis operation. There is the possibility of abnormal status in the XMP board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E602233 “Y-axis error: Failed to stop.”
[Cause]
Failed to stop Y-axis operation. There is the possibility of abnormal status in the XMP board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
122
E602333 “XR-axis error: Failed to stop.”
[Cause]
Failed to stop the XR-axis operation. There is the possibility of abnormal status in the XMP
board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E602433 “Yc-axis error: Failed to stop.”
[Cause]
Failed to stop the Yc-axis operation. There is the possibility of abnormal status in the XMP board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E602533 “YR-axis error: Failed to stop.”
[Cause]
Failed to stop the YR-axis operation. There is the possibility of abnormal status in the XMP
board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E602140 “X-axis error: Out of the movable range.”
[Cause]
The destination coordinates of the X-axis are out of the mechanical limit.
[Treatment]
Specify the destination coordinate of the X-axis within the movable range.
E602240 “Y-axis error: Out of the movable range.”
[Cause]
The destination coordinates of the Y-axis are out of the mechanical limit.
[Treatment]
Specify the destination coordinate of the Y-axis within the movable range.
E602340 “XR-axis error: Out of the movable range.”
[Cause]
The destination coordinates of the XR-axis are out of the mechanical limit.
[Treatment]
Specify the destination coordinate of the XR-axis within the movable range.
E602440 “Yc-axis error: Out of the movable range.”
[Cause]
The destination coordinates of the Yc-axis are out of the mechanical limit.
[Treatment]
Specify the destination coordinate of the Yc-axis within the movable range.
E602540 “YR-axis error: Out of the movable range.”
[Cause]