KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第1205页
122 E602333 “XR-axi s error: Failed t o stop.” [Cause] Failed to stop the X R-axis oper ation. Ther e is the poss ibility of abnorm al status in the X MP board. [Treatm ent] Please turn on the power supply of the m achin…
121
E602332 “XR-axis error: Failed to start.”
[Cause]
Failed to start the XR-axis operation. There is the possibility of abnormal status in the XMP
board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E602432 “Yc-axis error: Failed to start.”
[Cause]
Failed to start the Yc-axis operation. There is the possibility of abnormal status in the XMP board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E602532 “YR-axis error: Failed to start.”
[Cause]
Failed to start the YR-axis operation. There is the possibility of abnormal status in the XMP
board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E602536 “Axis Driver: YR-axis. The velocity error exceeded the limit. (Check
the power supply for the possibilities of low power supply voltage.)”
[Cause]
An error occurred in the servo system.
Fluctuations in the driving power may have prevented the proper operation of the system.
[Treatment]
Check the conditions of the machine power source.
E602133 “X-axis error: Failed to stop.”
[Cause]
Failed to stop X-axis operation. There is the possibility of abnormal status in the XMP board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E602233 “Y-axis error: Failed to stop.”
[Cause]
Failed to stop Y-axis operation. There is the possibility of abnormal status in the XMP board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
122
E602333 “XR-axis error: Failed to stop.”
[Cause]
Failed to stop the XR-axis operation. There is the possibility of abnormal status in the XMP
board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E602433 “Yc-axis error: Failed to stop.”
[Cause]
Failed to stop the Yc-axis operation. There is the possibility of abnormal status in the XMP board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E602533 “YR-axis error: Failed to stop.”
[Cause]
Failed to stop the YR-axis operation. There is the possibility of abnormal status in the XMP
board.
[Treatment]
Please turn on the power supply of the machine after finishing everything and shutting down the
machine.
If the error occurs even after the rebooting, there is the possibility of a broken system file, or
hardware failure in the XMP board or its connectors.
Please take a note of the error number and contact our technical service dept. for information.
E602140 “X-axis error: Out of the movable range.”
[Cause]
The destination coordinates of the X-axis are out of the mechanical limit.
[Treatment]
Specify the destination coordinate of the X-axis within the movable range.
E602240 “Y-axis error: Out of the movable range.”
[Cause]
The destination coordinates of the Y-axis are out of the mechanical limit.
[Treatment]
Specify the destination coordinate of the Y-axis within the movable range.
E602340 “XR-axis error: Out of the movable range.”
[Cause]
The destination coordinates of the XR-axis are out of the mechanical limit.
[Treatment]
Specify the destination coordinate of the XR-axis within the movable range.
E602440 “Yc-axis error: Out of the movable range.”
[Cause]
The destination coordinates of the Yc-axis are out of the mechanical limit.
[Treatment]
Specify the destination coordinate of the Yc-axis within the movable range.
E602540 “YR-axis error: Out of the movable range.”
[Cause]
123
The destination coordinates of the YR-axis are out of the mechanical limit.
[Treatment]
Specify the destination coordinate of the YR-axis within the movable range.
E603110 “LZ1-axis: Parameter error”
[Cause]
Incorrect parameters have been set for the LZ1-axis operation.
The data is damaged in the machine, or the version of the program installed is wrong.
[Treatment]
Turn off the power, then turn on the power again.
Install the machine software again if the problem occurred after installing the software for
updating, etc.
If the error remains after the above processes, the board in the machine causes the problem.
Replace the board.
E603112 “Axis Driver: Z1-axis failed originating.”
[Cause]
Failed to return the axis to the home position. The possible causes are as follows:
1. The servo power does not turn ON.
2. The servo cannot be locked.
3. The motor does not start.
4. The home sensor cannot be captured, or its state does not change.
5. The present position cannot be acquired.
[Treatment]
Exit the system. Check the conditions of the boards, connections, sensors and other possible
factors.
If the error persists, contact our service engineer or the agency.
E603113 “Axis Driver: Z1-axis error. Servo power is OFF.”
[Cause]
The servo power OFF was detected during or at the start of the operation.
An event that causes the servo-OFF may have occurred such as; the detection by the limit
sensor/area sensor/feeder float detector, or pressing of the emergency stop switch. Or, other
axis may have failed, resulting in cutting of the servo power.
[Treatment]
Remove the cause and return the axes to the home position.
If the error persists, exit the system and contact our service engineer or the agency.
E603114 “Axis Driver: Z1-axis error. Driver alarm.”
[Cause]
A servo driver alarm was detected during or at the start of the operation.
Possible cause is; poor contact or disconnection of the encoder cable, or a physical overload.
The alarm may also be caused if the emergency stop switch is pressed.
[Treatment]
Remove the cause and return the axes to the home position.
If the error persists, exit the system and contact our service engineer or the agency.
E603115 “Axis Driver: Z1-axis error. Amp disabled.”
[Cause]
A servo driver release was detected during or at the start of the operation.
Mechanical or electrical load fluctuations may have generated a servo error.
A driver alarm or pressing of the emergency stop switch can also release the servo lock.
[Treatment]
Remove the cause and return the axes to the home position.
If the error persists, exit the system and contact our service engineer or the agency.
E603120 “Axis Driver: Z1-axis gain setting failed.”
[Cause]
An internal error occurred in the system.
The XMP board may have failed.