161 the connector par t is brok en, that the wiring got cut off , or the solenoid valve itself is brok en. Please exam ine the wiring and connec tors. If any of them ar e brok en, you need to replace them with new ones..…
160
E610006 “A time-out occurred when shutting the ATC(R) slide plate”
[Cause] A process to close the right ATC slide plate was taken place but the plate did not
open within a certain amount of time. The follows could be the cause.
①
The air is not being supplied properly.
②
The slide plate that slides left and right to open and close the plate in the ATC
unit does not work properly.
③
The sensor which detects the position of the slide plate is not tuned well or
broken.
[Treatment] Please select [Manual Control] from the menu bar, and then select [Control(C )]
[Other(O)] [ATC Control(A)]. Set ‘Control Unit’ to ‘right ATC’, and select ‘Slide
plate Control(A)’ from the ‘Control Item’ frame’ to open/close the slide plate.
Please perform one of the treatments below according to the result you get.
1. Slide plate works properly.
1.1 The ‘Slide plate OFF sensor’ in the ‘Status’ displaying frame gets ON/OFF.
The speed controller of the Slide plate driving cylinder might be wrung too
much toward its minimum limit. Please loosen the controller.
1.2 The ‘Slide plate OFF sensor’ in the ‘Status’ displaying frame does not get
ON/OFF.
①
There is a possibility that the Slide plate OFF sensor was adjusted to
out of the Cylinder’s movable range. Please re-adjust the sensor to
where it gets ON/OFF.
②
If the treatment1 does not work, there is a possibility that the slide
plate OFF sensor is broken. It could be that the wiring came off the
connector part, that a contact pin in the connector part is broken, that
the wiring got cut off, or that the sensor itself is broken. Please
examine the wiring and connector. If any of them are broken, you
need to replace them with new ones.
③
If the treatment2 does not work, a PCB is broken or the wiring
between the PCBs is bad.
2. Slide plate does not work.
①
There is a possibility that the lock valve of the solenoid valve, that drives
the slide plate, is closed. Please make sure that the lock valve of the
solenoid valve is opened all the way.
②
There is a possibility that a nozzle is not installed in the ATC correctly and
that prevent the slide plate from sliding properly. Please see if nozzles are
correctly installed in the ATC.
③
There is a possibility that a component or implement got caught in the
sliding part of the slide plate and that prevents the slide plate from sliding
properly. Please see if there is anything on the slide plate.
④
There is a possibility that the air supplying pipes to the slide plate driving
cylinder have a problem. It could be that the speed controller is fully
tightened up, that the air pipe came off the cylinder, or a wrong air pipe is
connected to the cylinder. Please see the air pipes and make sure that
correct pipes are connected.
⑤
There is a possibility that the connecting part between the shaft of the
slide plate driving cylinder and the slide plate has a problem. It could be
that the nut attached to the tip of the shaft fell off, that the shaft got
chipped or broken, or that the plate got chipped or broken. You need to
have the damaged part repaired or replace it with a new one.
⑥
There is a possibility that the slide plate driving cylinder is broken. Please
stop the air supplying on the machine and see if the slide plate works fine
manually. If the plate does not work smoothly, you need to replace it with
a new one.
⑦
There is a possibility that the slide plate driving solenoid valve is broken. It
could be that the wiring came off the connector part, that a contact pin in
161
the connector part is broken, that the wiring got cut off, or the solenoid
valve itself is broken. Please examine the wiring and connectors. If any of
them are broken, you need to replace them with new ones..
⑧
If the treatments mentioned above do not work, a PCB is broken or the
wiring between the PCBs is bad.
E610007 “ATC(L) slide plate sensor is abnormal”
[Cause] The status of the slide plate ON sensor or OFF sensor of the left ATC slide plate
is abnormal. The slide plate ON sensor and OFF sensor got ON at the same
time.
[Treatment] Please select [Manual Control] from the menu bar, and then select [Control(C)]
[Other(O)][ATC Control(A)]. Set ‘Control Unit’ to ‘left ATC’, and select ‘Slide plate
Control(A)’ from the ‘Control Item’ frame’ to open/close the slide plate. Please
perform one of the treatments below according to the result you get.
1. ‘Slide plate ON sensor’ and ‘Slide plate OFF sensor’ in the ‘Status’ displaying
frame both get ON/OFF.
①
Slide plate ON sensor or Slide plate OFF sensor, or both, is on the wrong
position. There is a possibility that the sensors are too close to each other,
so widen the distance between the two.
②
If the treatment1 does not work, a PCB is broken or the wiring between
the PCBs is bad.
2. Either one of ‘Slide plate ON sensor’ or ‘Slide plate OFF sensor’ in the ‘Status’
displaying frame is always ON.
①
There is a possibility that the slide plate ON sensor or OFF sensor is
broken. It could be that the wiring came off the connector part, that a pin
in the connector part is broken, that the wiring got cut off, or the sensor
itself is broken. Please examine the wiring and the connector. If any of
them are broken, you need to replace them with new ones.
②
If the treatment1 does not work, a PCB is broken or the wiring between
the PCBs is bad.
E610008 “ATC(R) slide pate sensor is abnormal”
[Cause] The status of the slide plate ON sensor or OFF sensor of the right ATC slide plate
is abnormal. The slide plate ON sensor and OFF sensor got ON at the same
time.
[Treatment] Please select [Manual Control] from the menu bar, and then select [Control(C)]
[Other(O)][ATC Control(A)]. Set ‘Control Unit’ to ‘right ATC’, and select ‘Slide
plate Control(A)’ from the ‘Control Item’ frame’ to open/close the slide plate.
Please perform one of the treatments below according to the result you get.
1. Slide plate ON sensor’ and ‘Slide plate OFF sensor’ in the ‘Status’ displaying
frame both get ON/OFF.
①
Slide p sensor or Slide plate OFF sensor, or both, is on the wrong position.
There is a possibility that the sensors are too close to each other, so
widen the distance between the two.
②
If the treatment1 does late ON not work, a PCB is broken or the wiring
between the PCBs is bad.
2. Either one of ‘Slide plate ON sensor’ or ‘Slide plate OFF sensor’ in the ‘Status’
displaying frame is always ON.
162
①
There is a possibility that the slide plate ON sensor or OFF sensor is
broken. It could be that the wiring came off the connector part, that a pin
in the connector part is broken, that the wiring got cut off, or the sensor
itself is broken. Please examine the wiring and the connector. If any of
them are broken, you need to replace them with new ones.
②
If the treatment1 does not work, a PCB is broken or the wiring between the
PCBs is bad.
E610009 “Parameter for the head is not correct”
[Cause] Head specifying is abnormal. The data in the machine is broken or the version of
the software that is installed on the machine is not correct.
[Treatment] • Please turn off the power supply of your machine and reboot it.
• If the error occurred after the installation or the versionup of the software, you
need to re-install the software.
• If the treatments above do not work, there is a possibility that MPX board(s) in
the machine is broken. You need to replace it(them) with new ones.
E610010 “The specified cylinder does not exist”
[Cause] The specifying of ATC position is abnormal. The data in the machine is broken or
the version of the software that is installed on the machine is not correct.
[Treatment] • Please turn off the power supply of your machine and reboot it.
• If the error occurred after the installation or the versionup of the software, you
need to re-install the software.
• If the treatments above do not work, there is a possibility that MPX board(s) in
the machine is broken. You need to replace it(them) with new ones.
E610011 “An error occurred when starting XY axes movement”
[Cause] An error occurred when starting XY axes movement.
[Treatment] Please turn off the power supply of your machine and reboot it.
E610012 “An error occurred when starting X axis movement” "
[Cause] An error occurred when starting X axis (left side) movement.
[Treatment] Please turn off the power supply of your machine and reboot it.
E610013 “An error occurred when starting XR axis movement”
[Cause] An error occurred when starting X axis (right side) movement.
[Treatment] Please turn off the power supply of your machine and reboot it.
E610014 “An error occurred when starting Y axis movement”
[Cause] An error occurred when starting Y axis movement.
[Treatment] Please turn off the power supply of your machine and reboot it.
E610015 “An error occurred when starting Z axis movement”
[cause] An error occurred when starting X axis (nozzle up-and-down axis) movement.
[Treatment] Please turn off the power supply of your machine and reboot it.
E610016 “An error occurred when starting Theta axis revolution”
[Cause] An error occurred when starting Theta axis (nozzle revolving axis) revolution.