205 E631027 “ViRecog Error: Failed to f ind lead(s) . Please examine Pi ck position” [Cause] Pic king pos ture is not c orrect. The pic ked c om ponent is diff erent f rom a com ponent in the Com ponent data. The c om po…
204
E631025 “ViRecog Error: Failed to detect leads. Please examine the picking
posture”
[Cause] The picking posture is not correct.
The component is not being picked.
The picked component is different from a component in the Component data.
The light is either too bright or too dark.
The light is dirty.
The camera lens is dirty.
The light cable almost gets cut off.
The brilliancy of LED is varying.
[Treatment] Please examine the Pick data in the Production program.
Please examine the Component data (Vacuum value without component) in the
Production program.
Please examine the Component data in the Production program.
Please examine the Vision data in the Production program.
Please examine the light parameter in the Production program.
Please adjust the light parameter in the Production program.
Please clean the light.
Please clean the camera lens.
Please change the light cables.
Please re-adjust the electric currency of the light.
Please change the lights and re-adjust the electric currency of the new light.
Please change the light boards and re-adjust the electric currency of the new
board.
E631026 “ ViRecog Error: The number of leads is too small. Please examine
Vision data”
[Cause] The leads are too few.
The specified lead missing is wrong.
The component’s lead pitch is different.
Picking posture is not correct.
The picked component is different from a component in the Component data.
The light is either too bright or too dark
The light is dirty.
The camera lens is dirty.
The light cable almost gets cut off.
The brilliancy of LED is varying.
[Treatment] Please examine the number of leads in the production program.
Please examine the lead missing in the production program.
Please examine the lead pitch in the production program.
Please examine the Pick data in the production program.
Please examine the light parameter in the production program.
Please adjust the light parameter in the production program.
Please clean the light.
Please clean the camera lens.
Please change the light cables.
Please re-adjust the electric currency of the light.
Please change the lights and re-adjust the electric currency of the new light.
Please change the light boards and re-adjust the electric currency of the new
board.
205
E631027 “ViRecog Error: Failed to find lead(s). Please examine Pick
position”
[Cause] Picking posture is not correct.
The picked component is different from a component in the Component data.
The component is not being picked.
The light is either too bright or too dark
The light is dirty.
The camera lens is dirty.
The light cable almost gets cut off.
The brilliancy of LED is varying.
[Treatment] Please examine the Pick data in the production program.
Please examine the Component data in the production program.
Please examine the Vision data in the production program.
Please examine the Component data (Vacuum value without component) in the
production program.
Please examine the light parameter in the production program.
Please adjust the light parameter in the production program.
Please clean the light.
Please clean the camera lens.
Please change the light cables.
Please re-adjust the electric currency of the light.
Please change the lights and re-adjust the electric currency of the new light.
Please change the light boards and re-adjust the electric currency of the new
board.
E631028 “ViRecog Error:Mis-recognized the fine pitch lead. Please examine
Light conditions”
[Cause] The light is either too bright or too dark.
The light is dirty.
The camera lens is dirty.
The light cable almost gets cut off.
The brilliancy of LED is varying.
[Treatment] Please examine the light parameter in the production program.
Please adjust the light parameter in the production program.
Please clean the light.
Please clean the camera lens.
Please change the light cables.
Please re-adjust the electric currency of the light.
Please change the lights and re-adjust the electric currency of the new light.
Please change the light boards and re-adjust the electric currency of the new
board.
Q631180 “There is a similar pattern in the upper part of the template. Would
you like to take the teaching results in?”
[Cause] The user defined template has a similar patter in the upper part of the template.
[Treatment] Please re-teach other user defined templates to the machine.
If you do not have other user defined templates, current template will be taken in
although the template may not be recognized correctly.
206
Q631181 “There is a similar pattern in the lower part of the template. Would
you like to take the teaching results in?”
[Cause] The user defined template has a similar patter in the upper part of the template.
[Treatment] Please re-teach other user defined templates to the machine.
If you do not have other user defined templates, current template will be taken in
although the template may not be recognized correctly.
Q631182 “There is a similar pattern on the left side of the template. Would
you like to take the teaching results in?”
[Cause] The user defined template has a similar patter on the left side of the template.
[Treatment] Please re-teach other user defined templates to the machine.
If you do not have other user defined templates, current template will be taken in
although the template may not be recognized correctly.
Q631183 “There is a similar pattern on the right side of the template. Would
you like to take the teaching results in?”
[Cause] The user defined template has a similar patter on the left side of the template.
[Treatment] Please re-teach other user defined templates to the machine.
If you do not have other user defined templates, current template will be taken in
although the template may not be recognized correctly.
Q631184 “The template does not have enough contrast. Would you like to
take the teaching results in?”
[Cause] The user defined template does not have enough contrast.
[Treatment] Please re-teach other user defined templates to the machine.
If you do not have other user defined templates, current template will be taken in
although the template may not be recognized correctly.
Q631185 “The template has no features. Would you like to take the teaching
results in?”
[Cause] The specified user defined template does not have any notable patterns.
[Treatment] Please re-teach other user defined templates to the machine.
If you do not have other user defined templates, current template will be taken in
although the template may not be recognized correctly.
E631186 “The contrast for the entire image is too low. Please modify the
conditions and teach again”
[Cause] The specified user defined template does not have any notable patterns.
[Treatment] Please re-teach other user defined templates to the machine.