KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第1290页
207 Q631200 “The light is getti ng darker. Please clean t he light” [Cause] T he light is dir ty. The c am era lens is dirty. The c amer a cable alm ost gets cut of f. The light c able alm ost gets c ut off . The br illi…
206
Q631181 “There is a similar pattern in the lower part of the template. Would
you like to take the teaching results in?”
[Cause] The user defined template has a similar patter in the upper part of the template.
[Treatment] Please re-teach other user defined templates to the machine.
If you do not have other user defined templates, current template will be taken in
although the template may not be recognized correctly.
Q631182 “There is a similar pattern on the left side of the template. Would
you like to take the teaching results in?”
[Cause] The user defined template has a similar patter on the left side of the template.
[Treatment] Please re-teach other user defined templates to the machine.
If you do not have other user defined templates, current template will be taken in
although the template may not be recognized correctly.
Q631183 “There is a similar pattern on the right side of the template. Would
you like to take the teaching results in?”
[Cause] The user defined template has a similar patter on the left side of the template.
[Treatment] Please re-teach other user defined templates to the machine.
If you do not have other user defined templates, current template will be taken in
although the template may not be recognized correctly.
Q631184 “The template does not have enough contrast. Would you like to
take the teaching results in?”
[Cause] The user defined template does not have enough contrast.
[Treatment] Please re-teach other user defined templates to the machine.
If you do not have other user defined templates, current template will be taken in
although the template may not be recognized correctly.
Q631185 “The template has no features. Would you like to take the teaching
results in?”
[Cause] The specified user defined template does not have any notable patterns.
[Treatment] Please re-teach other user defined templates to the machine.
If you do not have other user defined templates, current template will be taken in
although the template may not be recognized correctly.
E631186 “The contrast for the entire image is too low. Please modify the
conditions and teach again”
[Cause] The specified user defined template does not have any notable patterns.
[Treatment] Please re-teach other user defined templates to the machine.
207
Q631200 “The light is getting darker. Please clean the light”
[Cause] The light is dirty.
The camera lens is dirty.
The camera cable almost gets cut off.
The light cable almost gets cut off.
The brilliancy of LED is varying.
The amount of the electric currency of the light is varying.
[Treatment] Please clean the light.
Please clean the camera lens.
Please change the camera cables.
Please change the light cables.
Please re-adjust the electric currency of the light.
Please change the lights and re-adjust the electric currency of the new light.
Please change the light boards and re-adjust the electric currency of the new
board.
E631201 “The light is too dark. Please clean the light”
[Cause] The light is dirty.
The camera lens is dirty.
The camera cable almost gets cut off.
The light cable almost gets cut off.
The brilliancy of LED is varying.
The amount of the electric currency of the light is varying.
[Treatment] Please clean the light.
Please clean the camera lens.
Please change the camera cables.
Please change the light cables.
Please re-adjust the electric currency of the light.
Please change the lights and re-adjust the electric currency of the new light.
Please change the light boards and re-adjust the electric currency of the new
board.
E631202 “The light is not ON. Please examine it”
[Cause] The camera cable is cut off.
The light cable is cut off.
LED is broken.
The light board is broken.
The camera is broken.
[Treatment] Please change the camera cables.
Please change the light cables.
Please change the lights and re-adjust the electric currency of the new light.
Please change the light boards and re-adjust the electric currency of the new
board.
Please change the cameras and re-enter the MS parameter.
208
W650009 “Conveying device error: Since a PWB which interferences the
check cylinder, the cylinder can not come up. Please remove the
PWB”
[Cause] Failed to lift up the cylinder that had been coming down since a PWB was
detected at the cylinder lifting-up position.
[Treatment] Please take the PWB off the conveyor.
E650010 “Conveying device error: Due to the abnormality of the check
cylinder sensor, cylinder can not come up. Please re-start the
machine and check again”
[Cause] The sensor of the check cylinder did not get ON within a certain time although
you tried to run the check cylinder.
[Treatment] Select [Manual Control] from the menu bar, and choose [Control(C)]
[Conveyor(C)] and [Movable station control(A)].@Select “PWB detect pin” from
the “Control Item” and [PWB detect pin(A)] from [Control item] frame to enable or
disable ON/OFF. The treatments to take depends on the result you get from the
action above.
1 Cylinder works fine.
1.1 The status of ‘PWB check sensor’ in the ‘status’ displaying frame gets
ON/OFF.
The cause might be that the speed controller of the PWB detector was
wrung too much. Please release the speed controller of the PWB
detector.
1.2 The status of ‘PWB check sensor’ in the ‘status’ displaying frame does
not get ON/OFF.
①
The cause might be that PWB check sensor was adjusted to out of the
operation range of the cylinder. Please re-adjust the sensor to where it
gets ON/OFF.
②
If the treatment1 above does not work, there is a possibility that the
PWB check sensor is broken. It could be that the wiring came out of
the connector part, that a contact pin of the connector part is broken,
that wiring got cut off, or that sensor itself is broken (If LED of the
PWB check sensor gets ON/OFF but the status of ‘PWB check
sensor’ in the ‘status’ displaying frame does not get ON/OFF, signal
line of the PWB check sensor may be either abnormal or cut off, or the
connector part does not work well). Please examine the wiring and
connector part. If any of them are broken, you need to replace them
with new ones.
②
If the treatment2 does not even work, PCB is broken or the wiring
between the PCBs is bad.
2 Cylinder does not work.
①
The cause might be the abnormality of the air plumbing to PWB detector.
It could be that the speed controller was wrung to its limit, that the air
plumbing came off, or that the air plumbing is wrong. Please examine the
air plumbing and see if it is connected properly.
②
The PWB detector itself may be broken. Please stop the air supply on the
machine and see if the cylinder shaft works properly or not manually. If
the shaft does not work smoothly, you need to replace it with a new one.
③
The driving solenoid valve may be broken. It could be that the wiring came
out of the connector part, that a contact pin in the connector is broken,
that wiring got cut off, or that the solenoid valve itself is broken. Please
examine the wiring and connector part. If anything wrong with them, you
need to replace them with new ones.
④
If none of the treatments above works, PCB is broken or the wiring
between the PCBs is bad.