230 terminated. Pl ease remove on the convey i ng route” [Cause] T he back up plate on the center station on the Exit s ide did not get to the aim ed clam p height. As a caus e, there is a pos sibility that the firmware …

100%1 / 1361
229
E650292 “Clamp error : Time-out occurred while backup plate of the center
station on the Exit side went up. The process is forcibly terminated.
Please remove on the conveying route”
[Cause] The backup plate on the center station on the Exit side did not get to the aimed
clamp height. As a cause, there is a possibility that the firmware on the XMP
board has a problem.
[Treatment] The firmware on the XMP board to make the backup plate up and down is not
under the control mode.
Please turn off the power supply of your machine and reboot it.
If the treatment1 does not work, please see if the wiring and connectors in
the XMP board are properly connected.
If the treatment2 does not work, you need to change the XMP board to a
new one.
E650293 “Clam error : Backup plate of the center station on the Exit side
went down illegally. The process is forcibly terminated. Please
remove on the conveying route”
[Cause] The backup plate on the center station on the Exit side did not get down to the
aimed clamp height. This error usually occurs when there happens a mechanical
hindrance to make the backup plate go down.
[Treatment] 1. If the backup table on the center station on the Exit side was down when the
error occurred.
An implement or component got caught between the PWB on the center station
on the Exit side and a frame or mechanism underneath it. Please examine if
there is anything under the backup table.
2. Backup table went down at a high speed, and the continuous collision sound
came out.
The encoder on the center station on the Exit side, that decides a position
of PWB may be broken. It could be that the wiring came off the connector
part that a contact pin in the connector part is broken, that wiring got cut
off, or that the encoder itself is broken. Please examine that wiring and
connector part. If any of them are broken, you need to replace them with
new ones.
There is a possibility that the screw that holds the encoder and the
encoder axis on the center station on the Exit side together is loose.
Please examine if the screw is tightened up enough.
If the treatments above do not work, PCB is broken or the wiring between
the PCBs is bad.
3. The motor made a noise but the backup table did not come down.
There is a possibility that the up-and-down motion system under the backup
table that is on the center station on the Exit side has a problem. The timing
belt, the screw that holds a belt pulley, or the screw that holds a motor may be
loose. Please see if the each part is tightened up enough.
4. The backup table did not come down and the motor did not make any noise.
There is a possibility that the stepping motor is broken. It could be that the
wiring came off the connector part, that a contact pin in the connector part
is broken, that the wiring got cut off, or that motor itself is broken. Please
examine the wiring and connector part. If any of them are broken, you
need to replace them with new ones.
If the treatment1 does not work, PCB is broken or the wiring between the
PCBs is bad.
E650294 “Clamp error : Time-out occurred while backup plate on the center
station on the Exit side went down. The process is forcibly
230
terminated. Please remove on the conveying route”
[Cause] The backup plate on the center station on the Exit side did not get to the aimed
clamp height. As a cause, there is a possibility that the firmware on the XMP
board has a problem.
[Treatment] The firmware on the XMP board to make the backup plate up and down is not
under the control mode.
Please turn off the power supply of your machine and reboot it.
If the treatment1 does not work, please see if the wiring and connectors in
the XMP board are properly connected.
If the treatment2 does not work, you need to change the XMP board to a
new one.
E650295 “Clamp error : Something is wrong with the backup motor
movement on the center station on the Exit side. The process is
forcibly terminated. Please remove on the conveying route”
[Cause] The backup plate on the center station on the Exit side did not get to the aimed
clamp height. As a cause, there is a possibility that the firmware on the XMP
board has a problem.
[Treatment] The firmware on the XMP board to make the backup plate up and down is not
under the control mode.
Please turn off the power supply of your machine and reboot it.
If the treatment1 does not work, please see if the wiring and connectors in
the XMP board are properly connected.
If the treatment2 does not work, you need to change the XMP board to a
new one.
E650296 “Clamp error : Hole reference process at the center station on the
Exit side finished illegally. The process is forcibly terminated.
Please remove on the conveying route”
[Cause] The backup plate got to the aimed clamp height but the Ref. pin sensor did not
get ON. This error is likely to occur when the Ref. pin did not get in the positioning
hole correctly.
[Treatment] 1 The Ref. pin on the center station on the Exit side is not in the positioning hole
correctly.
Please set the positions of the Ref. pin and the follower pin on the center
station on the Exit side correctly to the position of the Ref. hole. If you want to
position PWBs with Outer shape Ref., please make sure that “Outer shape
Ref.” is enabled in the PWB data in the Program Editor.
2 The Ref. pin on the center station on the Exit side is in the positioning hole
correctly.
Select [Manual Control] from the menu bar, and then select [Control(C)]
[Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of Ref.
pin sensor in the ‘Status’ frame. Select ‘backup plate’ in the ‘Control’ item’ on
this screen to make the backup plate up and down. At this point, set the
Destination@coordinates(up)(M) to -1.6mm.@
When the Ref. pin sensor in the ‘Status’ frame does not get ON/OFF,
there is a possibility that the sensor is not installed properly. Please
re-install the sensor to where it gets ON/OFF correctly.
231
When the Ref. pin sensor in the ‘Status’ frame does not get ON/OFF,
there is a possibility that the Ref. pin sensor is broken. It could be that the
wiring came off the connector, that a contact pin in the connector part is
broken, that wiring got cut off, or that sensor itself is broken. Please
examine the wiring and the connector. If any of them are broken, you
need to replace them with new ones.
When the Ref. pin sensor in the ‘Status’ frame does get ON/OFF, there is
a possibility that the signal line of the Ref. pin sensor is broken. It could be
that the wiring came off the connector part, that a contact pin in the
connector part is broken, or that signal line got cut off. Please examine
the wiring and the connector. There also is another possibility that the
screw that holds the encoder and the encoder axis together is loose.
Please make sure that the screw is tightened up enough.
If the treatments mentioned above do not work, a PCB is broken or the
wiring between the PCBs is bad.
W650309 “Idle PWB Conveying Error : PWB is detected on the conveying
route. Please remove it”
[Cause] In the Idle PWB Conveying process, several buffers on the conveying route
detected unexpected PWBs on the conveying route.
[Treatment] Please remove the PWBs on the conveyor.
W650311 “Idle PWB Conveying Error : A PWB is detected on the center
station. Please remove it”
[Cause] In the Idle PWB Conveying process, unexpected PWBs were detected on the
center station on the conveyor.
[Treatment] Please remove the PWBs on the center station.
W650312 “Idle PWB Conveying Error : A PWB is detected on the center
station on the Entrance side. Please remove it”
[Cause] In the KE2030 Idle PWB Conveying process, unexpected PWBs were detected
on the center station on the Entrance side on the conveyor.
[Treatment] Please remove the PWBs on the center station on the Entrance side.
W650313 “Idle PWB Conveying Error : A PWB is detected on the center
station on the Exit side. Please remove it”
[Cause] In the KE2030 Idle PWB Conveying process, unexpected PWBs were detected
on the center station on the Exit side on the conveyor.
[Treatment] Please remove the PWBs on the center station on the Exit side.
W650314 “Idle PWB Conveying Error : A PWB is detected on the OUT buffer.
Please remove it”
[Cause] In the Idle PWB Conveying process, unexpected PWBs were detected on the
OUT buffer conveyor.
[Treatment] Please remove the PWBs on the OUT buffer on the conveyor.