236 E650342 “Idl e PWB Convey ing Error : PWB conveying error of the center station on the Ent rance side. The process is forci bly terminated. Please remove on the convey ing route” [Cause] T his er ror occ urs if the S…

100%1 / 1361
235
A PWB with thickness of 0.3mm or less. Or a PWB with thickness of
4mm or more.
A PWB with mass of 2kg or more.
2 If the PWB had overrun over the WAIT sensor and gotten to the center station
when the error occurred.
The WAIT sensor is not detecting the PWB. Please select [Manual Control] from
the menu bar, and then select [Control(C )] [Conveyor(C )] [Independent
Control of Conveyor(I)] to see the status of WAIT sensor in the ‘Status’ frame.
There is a possibility that the WAIT sensor is broken. It could be that the
wiring came off the connector part, that a contact pin in the connector part
is broken, that the wiring got cut off, or that the sensor itself is broken.
Please examine the wiring and the connector. If any of them are broken,
you need to replace them with new ones.
If the treatment1 does not work, a PCB is broken or the wiring between
the PCBs is bad.
E650334 “Idle PWB Conveying Error : PWB conveying time out error of the
center station. The process is forcibly terminated. Please remove on
the conveying route”
[Cause] When inletting a PWB from the Input buffer to the center station, STOP sensor
did not get ON even though a certain amount of time has passed since the WAIT
sensor of the Input buffer got OFF. Usually, this error occurs when a PWB can
not go through the INPUT buffer for some reason.
[Treatment] 1 The PWB was on the position where it is NOT detected by WAIT and STOP
sensors when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
The conveyor width is not matching the PWB width. Please re-adjust the
conveyor width.
The PWB you are trying to convey does not match the specifications of
your machine. The following cases do not match your machine.
A PWB with thickness of 0.3mm or less. Or a PWB with thickness of
4mm or more.
A PWB with mass of 2kg or more.
2 If the PWB overran the STOP sensor when the error occurred.
The STOP sensor is not detecting the PWB. Please select [Manual Control]
from the menu bar, and then select [Control(C)] [Conveyor(C)] [Independent
Control of Conveyor(I)] to see the status of the STOP sensor in the ‘Status
frame.
The sensitivity of the STOP sensor may be too low. Please re-adjust the
sensitivity of the sensor, using the volume control knob attached to the
sensor.
If the treatment1 does not work, there is a possibility that the STOP
sensor is broken. It could be that the wiring came out of the connector
part, that a contact pin in the connector part is broken, that wiring got cut
off, or that sensor itself is broken. Please examine the wiring and the
connector. If any of them are broken, you need to replace them with the
new ones.
If the treatment2 does not work, PCB is broken or the wiring between the
PCBs is bad.
236
E650342 “Idle PWB Conveying Error : PWB conveying error of the center
station on the Entrance side. The process is forcibly terminated.
Please remove on the conveying route”
[Cause] This error occurs if the STOP sensor on the center station on the Entrance side
got OFF then ON again, but it does not get OFF even if a certain amount of time
has passed since it got ON again when conveying a PWB on the center station
on the Entrance side to the center station on the Exit side.
[Treatment] 1 The PWB was on the position where it is detected by the STOP sensor on the
center station on the Entrance side when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
The conveyor width is not matching the PW width. Please re-adjust the
conveyor width.
The PWB you are trying to convey does not match the specifications of
your machine. The following cases do not match your machine.
A PWB with thickness of 0.3mm or less. Or a PWB with thickness of
4mm or more.
A PWB with mass of 2kg or more.
2 If the PWB was NOT on the position where it is detected by the STOP sensor
on the center station on the Entrance side when the error occurred.
If the STOP sensor does not get OFF when a PWB is properly being
conveyed, there is a possibility that the sensor is detecting something else.
Please select [Manual Control] from the menu bar, and then select
[Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the
status of STOP sensor on the center station on the Entrance side in the
‘Status’ frame.
The sensitivity of the STOP sensor may be too high. Please re-adjust the
sensitivity of the sensor, using the volume control knob attached to the
sensor.
If the treatment1 does not work, there is a possibility that the STOP
sensor is broken. It could be that the wiring came out of the connector
part, that a contact pin in the connector part is broken, that wiring got cut
off, or that sensor itself is broken. Please examine the wiring and the
connector. If any of them are broken, you need to replace them with the
new ones.
If the treatment2 does not work, PCB is broken or the wiring between the
PCBs is bad.
E650343 “Idle PWB Conveying Error : PWB conveying error of the center
station on the Entrance side. The process is forcibly terminated.
Please remove on the conveying route”
[Cause] This error occurs if the C-OUT sensor on the center station on the Entrance side
got OFF then ON again, but it does not get OFF even if a certain amount of time
has passed since it got ON again when conveying a PWB on the center station
on the Entrance side to the center station on the Exit side.
[Treatment] 1 The PWB was on the position where it is detected by the STOP sensor on the
center station on the Entrance side when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
The conveyor width is not matching the PW width. Please re-adjust the
conveyor width.
The PWB you are trying to convey does not match the specifications of
your machine. The following cases do not match your machine.
A PWB with thickness of 0.3mm or less. Or a PWB with thickness of
4mm or more.
A PWB with mass of 2kg or more.
237
2 If the PWB was NOT on the position where it is detected by the C-OUT sensor
on the center station on the Entrance side when the error occurred.
If the C-OUT sensor does not get OFF when a PWB is properly being
conveyed, there is a possibility that the sensor is detecting something else.
Please select [Manual Control] from the menu bar, and then select
[Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the
status of C-OUT sensor on the center station on the Entrance side in the
‘Status’ frame.
The sensitivity of the C-OUT sensor may be too high. Please re-adjust the
sensitivity of the sensor, using the volume control knob attached to the
sensor.
If the treatment1 does not work, there is a possibility that the C-OUT
sensor is broken. It could be that the wiring came out of the connector
part, that a contact pin in the connector part is broken, that wiring got cut
off, or that sensor itself is broken. Please examine the wiring and the
connector. If any of them are broken, you need to replace them with the
new ones.
If the treatment2 does not work, PCB is broken or the wiring between the
PCBs is bad.
E650344 “Idle PWB Conveying Error : PWB conveying time out error of the
center station on the Entrance side. The process is forcibly
terminated. Please remove on the conveying route”
[Cause] This error occurred because the STOP sensor on the center station on the Exit
side did not get ON even though a certain amount of time has passed since the
WAIT sensor on the center station on the Entrance side got OFF when conveying
a PWB on the center station on the Entrance side to the center station on the Exit
side. Usually, this error occurs when a PWB can not go through the INPUT buffer
for some reason.
[Treatment] 1 If the PWB was on the position where it is NOT detected by WAIT sensor or
the STOP sensor on the center station on the Entrance side.
The PWB can not move for it got caught on the conveyor for some reason.
The conveyor width is not matching the PWB width. Please re-adjust the
conveyor width.
The PWB you are trying to convey does not match the specifications of
your machine. The following cases do not match your machine.
A PWB with thickness of 0.3mm or less. Or a PWB with thickness of
4mm or more.
A PWB with mass of 2kg or more.
2 If the PWB overran the STOP sensor when the error occurred.
The STOP sensor on the center station on the Entrance side is not detecting
the PWB. Please select [Manual Control] from the menu bar, and then select
[Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the
status of STOP sensor on the center station on the Entrance side in the
‘Status’ frame.
The sensitivity of the STOP sensor on the center station on the Entrance
side may be too high. Please re-adjust the sensitivity of the sensor, using
the volume control knob attached to the sensor.
If the treatment1 does not work, there is a possibility that the STOP
sensor on the center station on the Entrance side is broken. It could be
that the wiring came out of the connector part, that a contact pin in the
connector part is broken, that wiring got cut off, or that sensor itself is
broken. Please examine the wiring and the connector. If any of them are
broken, you need to replace them with the new ones.
If the treatment2 does not work, PCB is broken or the wiring between the
PCBs is bad.