KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第1327页

244 E651006 “An error occurred while issui ng command run event” [Cause] An er ror oc curred ins ide the Auto. PW B W idth Alignm ent c ontrol device dr iver. • An error occ urred while iss uing a com m and event. [Treat…

100%1 / 1361
243
E651001 “Returning to ORIGIN has not been done”
[Cause] Returning to ORIGIN of Auto. PWB Width Alignment control has not been
complete.
In order to adjust the Auto. PWB Width Alignment control, ORIGIN returning has
to be done.
[Treatment] Please complete the ORIGIN returning by pressing the ORIGIN button.
E651002 “An error occurred when returning to ORIGIN”
[Cause] An error occurred while Auto. PWB Width Alignment control was returning to its
ORIGIN.
[Treatment] Please turn off the power supply of your ma chine and re-boot it. If the error
occurs even after the re-boot, please contact our technical service dept. for
information.
E651003 “There is no need to move”
[Cause] There is no need to adjust the Auto. PWB Width Alignment control since the
board width got to the required width already.
[Treatment]
E651004 “The traveling movement has discontinued due to Backup pin
detection”
[Cause] The traveling movement got discontinued since the backup pin detecting sensor
detected something while the movement.
A backup pin was detected.
A conveying unit (Stopper pin unit, STOP C-OUT sensor unit, Outer shape X
pusher unit) interferes.
The installation position of the Backup pin detecting sensor is wrong.
The Backup pin detecting sensor is broken.
[Treatment] If a cause of the abortion is a detected backup pin, please adjust a position of
the backup pin.
If a cause of the abortion is an interference with a conveying unit, please
adjust a position of the conveying unit.
Please adjust the position of a unit that interferes.
Since the Backup pin detecting sensor has separated light emitter and light
receiver. Therefore, the sensor could be ON if the installation positions of the
emitter and receiver are wrong. If there is anything to interfere the sensor but
the sensor is ON, you need to adjust the installation position of the sensor.
Please examine the status of the sensor by adjusting the Auto. PWB Width
Alignment control with Manual control.
If the error still occurs even after all the treatments above were taken place,
there is a possibility that the sensor is broken. Please contact our technical
service dept. for information.
E651005 “More than one command were tried to start at one time”
[Cause] Several commands to the Auto. PWB Width Alignment control device driver got
started at one time.
[Treatment] Please re-start the application.
Please re-install or version-up the application.
If the error still occurs even after all the treatments above were taken place,
please contact our technical service dept. for information.
244
E651006 “An error occurred while issuing command run event”
[Cause] An error occurred inside the Auto. PWB Width Alignment control device driver.
An error occurred while issuing a command event.
[Treatment] Please re-start the application.
Please re-install or version-up the application.
If the error still occurs even after all the treatments above were taken place,
please contact our technical service dept. for information.
E651007 “A time-out occurred while waiting for a command to be complete”
[Cause] An error occurred inside the Auto. PWB Width Alignment control device driver.
A time-out error occurred while waiting for a command to be complete.
[Treatment] Please re-start the application.
Please re-install or version-up the application.
If the error still occurs even after all the treatments above were taken place,
please contact our technical service dept. for information.
E651008 “Although the motor stopped, encoder does not stop”
[Cause] It is confirmed that the motor of the Auto. PWB Width Alignment control has
stopped but not the encoder.
The Auto. PWB Alignment control unit is broken.
[Treatment] Please examine the Auto. PWB Width Alignment control with Manual control.
Please turn off the power supply of your machine and re-boot it. If the error
occurs even after the re-boot, please contact with our technical service dept.
for information.
E651009 “An error occurred when starting the motor”
[Cause] An error occurred when the motor of the Auto. PWB Width Alignment control got
started.
[Treatment] Please turn off the power supply of your machine and re-boot it. If the error
occurs even after the re-boot, please contact with our technical service dept. for
information.
E651010 “An error occurred while waiting for the motor to stop”
[Cause] An error occurred while the motor of the Auto. PWB Width Alignment control was
moving.
[Treatment] Please turn off the power supply of your machine and re-boot it. If the error
occurs even after the re-boot, please contact with our technical service dept. for
information.
E651011 “An error occurred while reading ORIGIN sensor in” "
[Cause] An error occurred while reading the ORIGIN sensor of the Auto. PWB Width
Alignment control in.
[Treatment] Please turn off the power supply of your machine and re-boot it. If the error
occurs even after the re-boot, please contact with our technical service dept.
for information.
245
E690001 “CVS is not installed”
[Cause] CVS is not installed on the machine.
[Treatment] If CVS is actually installed on your machine, please enable the unit in the MS
parameter option.
E690002 “Impossible to switch to Resistance Measurement mode since the
probe has not shut down. | Please shut the probe down then try
again”
[Cause] In order to set measurement mode to the Resistance mode, the probe has to be
closed to adjust resistance.
The probe is not closed.
[Treatment] Please close the probe then set the measurement mode.
E690003 “Impossible to switch to Condenser Measurement mode since the
probe has not shut down. | Please shut the probe down then try
again”
[Cause] In order to set measurement mode to the Condenser mode, the probe has to be
closed to adjust capacity.
The probe is not closed.
[Treatment] Please close the probe then set the measurement mode.
E690004 “The measurement mode is not correct
[Cause] The measurement mode parameter is not correct.
[Treatment] Please re-start the application.
Please re-install or version-up the application.
If the error occurs even after the treatments above were performed, please
contact our technical service dept. for information.
E690005 “Parameter to control probe is not correct”
[Cause] The parameter to control probe is not correct.
[Treatment] Please re-start the application.
Please re-install or version-up the application.
If the error occurs even after the treatments above were performed, please
contact our technical service dept. for information.
E690006 “Probe has to be shut down to measure resistance. | Please shut
probe then try again”
[Cause] In order to measurement resistance, the probe has to be closed.
The probe is not closed.
The probe is not closed.
[Treatment] Please close the probe then measure the resistance.
E690007 “Probe has to be shut down to measure condenser. | Please shut
probe then try again”
[Cause] In order to measurement condenser capacity, the probe has to be closed.
The probe is not closed.
The probe is not closed.
[Treatment] Please close the probe then measure the condenser capacity.