KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第1328页

245 E690001 “CVS is not instal led” [Cause] CVS is not installed on the m achine. [Treatm ent] If CVS is ac tually installed on y our m achine, please enable the unit in the MS param eter option. E690002 “I mpossible to …

100%1 / 1361
244
E651006 “An error occurred while issuing command run event”
[Cause] An error occurred inside the Auto. PWB Width Alignment control device driver.
An error occurred while issuing a command event.
[Treatment] Please re-start the application.
Please re-install or version-up the application.
If the error still occurs even after all the treatments above were taken place,
please contact our technical service dept. for information.
E651007 “A time-out occurred while waiting for a command to be complete”
[Cause] An error occurred inside the Auto. PWB Width Alignment control device driver.
A time-out error occurred while waiting for a command to be complete.
[Treatment] Please re-start the application.
Please re-install or version-up the application.
If the error still occurs even after all the treatments above were taken place,
please contact our technical service dept. for information.
E651008 “Although the motor stopped, encoder does not stop”
[Cause] It is confirmed that the motor of the Auto. PWB Width Alignment control has
stopped but not the encoder.
The Auto. PWB Alignment control unit is broken.
[Treatment] Please examine the Auto. PWB Width Alignment control with Manual control.
Please turn off the power supply of your machine and re-boot it. If the error
occurs even after the re-boot, please contact with our technical service dept.
for information.
E651009 “An error occurred when starting the motor”
[Cause] An error occurred when the motor of the Auto. PWB Width Alignment control got
started.
[Treatment] Please turn off the power supply of your machine and re-boot it. If the error
occurs even after the re-boot, please contact with our technical service dept. for
information.
E651010 “An error occurred while waiting for the motor to stop”
[Cause] An error occurred while the motor of the Auto. PWB Width Alignment control was
moving.
[Treatment] Please turn off the power supply of your machine and re-boot it. If the error
occurs even after the re-boot, please contact with our technical service dept. for
information.
E651011 “An error occurred while reading ORIGIN sensor in” "
[Cause] An error occurred while reading the ORIGIN sensor of the Auto. PWB Width
Alignment control in.
[Treatment] Please turn off the power supply of your machine and re-boot it. If the error
occurs even after the re-boot, please contact with our technical service dept.
for information.
245
E690001 “CVS is not installed”
[Cause] CVS is not installed on the machine.
[Treatment] If CVS is actually installed on your machine, please enable the unit in the MS
parameter option.
E690002 “Impossible to switch to Resistance Measurement mode since the
probe has not shut down. | Please shut the probe down then try
again”
[Cause] In order to set measurement mode to the Resistance mode, the probe has to be
closed to adjust resistance.
The probe is not closed.
[Treatment] Please close the probe then set the measurement mode.
E690003 “Impossible to switch to Condenser Measurement mode since the
probe has not shut down. | Please shut the probe down then try
again”
[Cause] In order to set measurement mode to the Condenser mode, the probe has to be
closed to adjust capacity.
The probe is not closed.
[Treatment] Please close the probe then set the measurement mode.
E690004 “The measurement mode is not correct
[Cause] The measurement mode parameter is not correct.
[Treatment] Please re-start the application.
Please re-install or version-up the application.
If the error occurs even after the treatments above were performed, please
contact our technical service dept. for information.
E690005 “Parameter to control probe is not correct”
[Cause] The parameter to control probe is not correct.
[Treatment] Please re-start the application.
Please re-install or version-up the application.
If the error occurs even after the treatments above were performed, please
contact our technical service dept. for information.
E690006 “Probe has to be shut down to measure resistance. | Please shut
probe then try again”
[Cause] In order to measurement resistance, the probe has to be closed.
The probe is not closed.
The probe is not closed.
[Treatment] Please close the probe then measure the resistance.
E690007 “Probe has to be shut down to measure condenser. | Please shut
probe then try again”
[Cause] In order to measurement condenser capacity, the probe has to be closed.
The probe is not closed.
The probe is not closed.
[Treatment] Please close the probe then measure the condenser capacity.
246
E690008 “Diode measurement is not available unless probe shuts down. |
Please shut probe then try again”
[Cause] The probe has to be closed to measure diode polarity.
The probe is not closed.
[Treatment] Please close the probe then try the measurement.
E690009 “The measurement is impossible since measurement mode is not
set to Resistance measurement. | Please switch to the Resistance
measurement mode then try again”
[Cause] In order to measure resistance, the measurement mode has to be the Resistance
measurement mode.
Measurement mode is not set to the Resistance measurement mode.
[Treatment] Please set the measurement mode to the Resistance measurement mode and try
again.
E690010 “The measurement is impossible since measurement mode is not
set to Condenser measurement. | Please switch to the Condenser
measurement mode then try again”
[Cause] In order to measure condenser capacity, the measurement mode has to be the
Condenser measurement mode.
Measurement mode is not set to the Condenser measurement mode.
[Treatment] Please set the measurement mode to the Condenser measurement mode and try
again.
E690011 “The measurement is impossible since measurement mode is not
set to Diode measurement. | Please switch to the Diode
measurement mode then try again”
[Cause] In order to measure diode polarity, the measurement mode has to be the Diode
measurement mode.
Measurement mode is not set to the Diode measurement mode.
[Treatment] Please set the measurement mode to the Diode measurement mode and try
again
E690012 “The measurement is impossible since the gotten measurement
mode is set to Resistance measurement”
[Cause] The measurement mode gotten from the tester is not the Resistance
measurement.
The specified measurement mode and the measurement mode gotten from the
tester are clashing with each other.
The Component Verification is broken.
[Treatment] If the error occurs even after a re-try, please turn off the power supply and
re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the
Component Verification unit is broken. Please contact our technical service
dept. for information.
E690013 “The measurement is impossible since the gotten measurement
mode is set to Condenser measurement”
[Cause] The measurement mode gotten from the tester is not the Condenser
measurement.
The specified measurement mode and the measurement mode gotten from the