250 E690028 “Resist ance can no be measured. Please check i f probe shuts dow n properly” [Cause] T he tester overflowed data when meas uring the res istance. • The objec t(com ponent) of the m easurem ent is not contact…

100%1 / 1361
249
E690023 “Something is wrong with the measured volume”
[Cause] The condenser capacity gotten from the tester is irregular.
The object(component) of the measurement is not contacting the probe well.
Component Verification is broken.
[Treatment] Please check and see if the object is contacting the probe well. If not, please
adjust the position of the object to contact the probe properly.
If the error occurs when the contact is good, there is a possibility that the
Component Verification unit is broken. Please contact our technical service
dept. for information.
E690024 “Something is wrong with the measured voltage”
[Cause] The voltage gotten from the tester is irregular.
The object(component) of the measurement is not contacting the probe well.
Component Verification is broken.
[Treatment] Please check and see if the object is contacting the probe well. If not, please
adjust the position of the object to contact the probe properly.
If the error occurs when the contact is good, there is a possibility that the
Component Verification unit is broken. Please contact our technical service
dept. for information.
E690025 “Something is wrong with the measured resistance(unit)”
[Cause] The unit for the resistance gotten from the tester is irregular.
The object(component) of the measurement is not contacting the probe well.
Component Verification is broken.
[Treatment] Please check and see if the object is contacting the probe well. If not, please
adjust the position of the object to contact the probe properly.
If the error occurs when the contact is good, there is a possibility that the
Component Verification unit is broken. Please contact our technical service
dept. for information.
E690026 “Something is wrong with the measured volume(unit)”
[Cause] The unit for the condenser capacity gotten from the tester is irregular.
The object(component) of the measurement is not contacting the probe well.
Component Verification is broken.
[Treatment] Please check and see if the object is contacting the probe well. If not, please
adjust the position of the object to contact the probe properly.
If the error occurs when the contact is good, there is a possibility that the
Component Verification unit is broken. Please contact our technical service
dept. for information.
E690027 “Something is wrong with the measured voltage(unit)
[Cause] The unit for the condenser capacity gotten from the tester is irregular.
The object(component) of the measurement is not contacting the probe well.
Component Verification is broken.
[Treatment] Please check and see if the object is contacting the probe well. If not, please
adjust the position of the object to contact the probe properly.
If the error occurs when the contact is good, there is a possibility that the
Component Verification unit is broken. Please contact our technical service
dept. for information.
250
E690028 “Resistance can no be measured. Please check if probe shuts
down properly”
[Cause] The tester overflowed data when measuring the resistance.
The object(component) of the measurement is not contacting the probe.
The contact between the object(component) of the measurement and the
probe is not good.
The resistance of the object(component) of the measurement is exceeding the
measurement range.
The Component Verification is broken.
[Treatment] Please check and see if the object is contacting the probe well. If not, please
adjust the position of the object to contact the probe properly.
Please check the object.
If the error occurs when the contact is good, there is a possibility that the
Component Verification unit is broken. Please contact our technical service
dept. for information.
E690029 “Volume can not be measured. Please check if probe shuts down
properly”
[Cause] The tester overflowed data when measuring the condenser capacity.
The object(component) of the measurement is not contacting the probe.
The contact between the object(component) of the measurement and the
probe is not good.
The resistance of the object(component) of the measurement is exceeding the
measurement range.
The Component Verification is broken.
[Treatment] Please check and see if the object is contacting the probe well. If not, please
adjust the position of the object to contact the probe properly.
Please check the object.
If the error occurs when the contact is good, there is a possibility that the
Component Verification unit is broken. Please contact our technical service
dept. for information.
E690030 “Voltage can not be measured. Please check if probe shuts down
properly”
[Cause] The tester overflowed data when measuring the diode polarity.
The object(component) of the measurement is not contacting the probe.
The contact between the object(component) of the measurement and the
probe is not good.
The resistance of the object(component) of the measurement is exceeding the
measurement range.
The Component Verification is broken.
[Treatment] Please check and see if the object is contacting the probe well. If not, please
adjust the position of the object to contact the probe properly.
Please check the object.
If the error occurs when the contact is good, there is a possibility that the
Component Verification unit is broken. Please contact our technical service
dept. for information.
E691001 “Input/Output buffer status of CCL-48M does not get ready”
[Cause] The input/output buffer status of the backup table counter(CCL-48M) does not get
ready.
Backup table counter is broken.
[Treatment] Please turn off the power supply and re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the Safety
board is broken. Please contact our technical service dept. for information.
251
E691002 “Writing-in buffer of flush memory does not get useable”
[Cause] ‘Writing-in’ buffer did not get useable when checking its status after a ‘writing-in’
command to flush memory was issued.
Flush memory is broken.
[Treatment] Please turn off the power supply and re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the Safety
board is broken. Please contact our technical service dept. for information.
E691003 “Deleting cue of flush memory does not get useable”
[Cause] ‘Deleting’ cue did not get useable when checking its status after a ‘deleting’
command to flush memory was issued.
Flush memory is broken.
[Treatment] Please turn off the power supply and re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the Safety
board is broken. Please contact our technical service dept. for information.
E691004 “WSM(Write State Machine) of flush memory does not get ready”
[Cause] ‘WSM’ did not get ready when checking its status after a command to flush
memory was issued.
Flush memory is broken.
[Treatment] Please turn off the power supply and re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the Safety
board is broken. Please contact our technical service dept. for information.
E691005 “Write-in voltage range error occurred in flush memory control”
[Cause] An error occurred while checking the ‘Write-in’ voltage status after a command to
flush memory was issued.
The process was aborted since the ‘write-in’ voltage is too low.
Flush memory is broken.
[Treatment] Please turn off the power supply and re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the Safety
board is broken. Please contact our technical service dept. for information.
E691006 “Write-in error occurred in flush memory control”
[Cause] An error occurred while checking the ‘device protecting’ status after a command
to flush memory was issued.
The process was aborted since the master lock bit, block lock bit, and RP# lock
were detected.
Flush memory is broken.
[Treatment] Please turn off the power supply and re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the Safety
board is broken. Please contact our technical service dept. for information.
E691007 “Write-in error occurred in flush memory control”
[Cause] An error occurred while checking the ‘Write-in’ status after a command to flush
memory was issued.
An error occurred while writing data in.
Flush memory is broken.
[Treatment] Please turn off the power supply and re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the Safety
board is broken. Please contact our technical service dept. for information.