KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第243页
4 – 136 Data ty pe Item Error conditions Component data and component pick-up position data (for a KE-2030) If the “Parallel Mode” is selected at the menu item “2030 Mode Specification” of the “2000 O ption” tab, and “Us…

4 – 135
Data type Item Error conditions
Component dimensions
Note:
△
means that the indicated dimensions are applicable
if an image of a component such as a connector is
divided, then recognized. The maximum dimensions
of a component is 150 mm (150 x 50). When you do
not use he FMLA head of a KE-2020, the maximum
dimensions are 29 mm.
If the machine does not use the KE-2020 MNLA
head, the minimum dimension is 0.45 mm or less.
Note: When the machine does not use the KE-2020 FMLA
head, the maximum length of a diagonal line of a
component is 30.7 mm or less.
Chip rise detecting option
There is not any station that can handle a chip rise detection
unit.
Head (when vision centering)
All of the FMLA heads (R head for a KE-2020, L and R
heads for a KE-2040) are set to “Not used” on the Setup
menu.
*1
Head (when laser centering)
All of the NMLA heads/FMLA heads are set to “Not used” on
the Setup menu, and those heads are set to “Used” on the
Component data editing screen.
Nozzle data (“Grip Position”
and “Nozzle Direction at
Picking”)
- A value other than “0” is set to the X” field of the menu item
“Grip Position.”
- A value other than 0, 90, 180 and 270 degrees is set at the
menu item “Nozzle Direction at Picking.”
Shuttle (Expansion –
MTC/MTS/DTS)
The “Packaging style” is set to “Tray”, “Feeder” is set to
“MTC/MTS”, “Compo Reject to” is set to “Tray Restore”,
“Shuttle” is set to “Mecha”, and there is only an MTC(s) in the
line.
Component
data
Prerotate angle (When
laser-centering)
The prerotate angle (A) is not set to a value within the
regulated range: 0 degree
≦
A
<
45 degrees.
*1: Items applicable to machines other than a KE-2010
Component
dimensions
2010 2020 2030 2040
L < 0.45 mm ○
○
Note
○
0.45 ≦ L ≦ 26.5mm ○ ○ ○ ○
26.5 < L ≦ 50 mm
○
Note
○
50 < L ≦ 150 mm △ △
The length of a
diagonal line of a
component to be
centered with laser
2010 2020 2030 2040
30.7 mm or less ○ ○ ○ ○
30.7 mm to 47 mm
○
Note
○

4 – 136
Data type Item Error conditions
Component data and
component pick-up position
data (for a KE-2030)
If the “Parallel Mode” is selected at the menu item “2030
Mode Specification” of the “2000 Option” tab, and “Use
manual station/position assignments” is selected at the menu
item “Pick Data” of the “Assignments” tab of the
“Optimization” menu, the machine checks to see if the
component pick-up position specified on Pick data is
consistent with that of each corresponding component data
record.
<Error conditions of Pick data associated with Component
data>
Component layer
(for a KE-2030)
If the “Sequential and Mix Mode” is selected at the menu item
“2030 Mode Specification” of the “2000 Option” tab, “Use
manual station/position assignments” is selected at the menu
item “Pick Data” on the “Assignments” tab, the component
pick-up position is specified at all of Pick data records, the
same layer number is assigned to the OUT station on
Placement data (see “Placement layer (for a KE-2030) of
Placement data) and the layers are not assigned in the order:
IN station and OUT station on Component data.
Maximum CL value on the IN side
≦
Minimum simultaneous
placement CL value
≦
Maximum simultaneous placement
CL value
≦
Minimum CL value on the OUT side
CL: Component layer number
Component
data
Use pick data/Not to use pick
data
If the pickup positions of all linked Pick data are specified and
“Not to use pick data” is selected at all Pick data (except the
case where all placement data linked to the corresponding
component are set to be skipped).
Component pick-up position
specified on Pick data
Consistency
check result
AUTO ○
Only one station
×
Only Both stations one station, AUTO ○
Both stations ○

4 – 137
(3-3) Coherence check items: error conditions
Data type Item Error conditions
Pick-up of vision components
The FMLA head (R head for a KE-2020, L and R heads
for KE-2040) is set to “Not used” in Pick data of vision
components.
*1
Placement of vision
components (over 0.4 mm)
(Lead components)
The standard VCS or optional VCS (37.5 mm, 27 mm or
18 mm) is not set in Placement data of vision
components whose size is 0.4 mm or larger.
*1
Placement of vision
components (0.3 <= Pitch < 0.4
mm) (Lead components)
The optional VCS (37.5 mm, 27 mm or 18 mm) is not
set in Placement data of vision components whose pitch
is 0.3 mm or wider, but narrower than 0.4 mm.
*1
Placement of vision
components (0.2 <= Pitch < 0.3
mm) (Lead components)
The optional VCS (27 mm or 18 mm) is not set in
Placement data of vision components whose pitch is 0.2
mm or wider, but narrower than 0.3 mm.
*1
Placement of vision
components (0.135 <= Pitch <
0.2 mm) (Lead components)
The optional 18 mm VCS is not set in Placement data of
vision components whose pitch is 0.135 mm or wider,
but narrower than 0.2 mm.
*1
Placement of general vision
components (15 < the smallest
pitch <= 22 mm) (Lead
components)
The standard VCS is not set in Placement data of
general vision components whose minimum pitch is
wider than 15 mm, but 22 mm or narrower.
*1
Placement of general vision
components (11 < the smallest
pitch <= 15 mm) (Lead
components)
The standard VCS or optional 37.5 mm VCS is not set
in Placement data of general vision components whose
minimum pitch is wider than 11 mm, but 15 mm or
narrower.
*1
Placement of general vision
components (6.5 < the smallest
pitch <= 11 mm) (Lead
components)
The standard VCS or optional 37.5 mm or 27 mm VCS
is not set in Placement data of general vision
components whose minimum pitch is wider than 6.5
mm, but 11 mm or narrower.
*1
Placement of general vision
components (0.5 <= the
smallest pitch <= 6.5 mm)
(Lead components)
The standard VCS or optional 37.5 mm, 27 mm or 18
mm VCS is not set in Placement data of general vision
components whose minimum pitch is 0.5 mm or wider,
but 6.5 mm or narrower.
*1
Placement of general vision
components (0.4 <= the
smallest pitch < 0.5 mm) (Lead
components)
The optional 37.5 mm, 27 mm or 18 mm VCS is not set
in Placement data of general vision components whose
minimum pitch is 0.4 mm or wider, but narrower than 0.5
mm.
*1
Placement of general vision
components (0.3 <= the
smallest pitch < 0.4 mm) (Lead
components)
The optional 27 mm or 18 mm VCS is not set in
Placement data of general vision components whose
minimum pitch is 0.3 mm or wider, but narrower than 0.4
mm.
*1
Placement of general vision
components (0.2 <= the
smallest pitch < 0.3 mm) (Lead
components)
The optional 18 mm VCS is not set in Placement data of
general vision components whose minimum pitch is 0.2
mm or wider, but narrower than 0.3 mm.
*1
Placement of vision
components (15 < the smallest
pitch <= 22 mm) (Ball
components)
The standard VCS is not set in Placement data of vision
components whose minimum pitch is wider than 15 mm,
but 22 mm or narrower.
*1
Placement of vision
components (11 < the smallest
pitch <= 15 mm) (Ball
components)
The standard VCS or optional 37.5 mm VCS is not set
in Placement data of vision components whose
minimum pitch is wider than 11 mm, but 15 mm or
narrower.
*1
Pick data
Placement of vision
components (6.5 < the smallest
pitch <= 11 mm) (Ball
components)
The standard VCS or optional 37.5 mm or 27 mm VCS
is not set in Placement data of vision components
whose minimum pitch is wider than 6.5 mm, but 11 mm
or narrower.
*1
*1: Items applicable to machines other than a KE-2010