KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第246页
4 – 139 Data ty pe Item Error conditions The system cannot handle a bulk feeder ty pe (BF25RS, BF25CS, BF28RS or BF28CS). *1 Bulk feeder type (BF25RS, BF25CS, BF28RS, BF28CS) There is no available bulk feeder (BF25R S, B…

4 – 138
Data type Item Error conditions
Placement of vision
components (1.0 <= the
smallest pitch <= 6.5 mm) (Ball
components)
The standard VCS or optional 37.5 mm, 27 mm or 18
mm VCS is not set in Placement data of vision
components whose minimum pitch is wider than 1.0
mm, but 6.5 mm or narrower.
*1
Placement of vision
components (0.8 <= the
smallest pitch < 1.0 mm) (Ball
components)
The optional 37.5 mm, 27 mm or 18 mm VCS is not set
in Placement data of vision components whose
minimum pitch is 0.8 mm or wider, but narrower than 1.0
mm.
*1
Placement of vision
components (0.5 <= the
smallest pitch < 0.8 mm) (Ball
components)
The optional 27 mm or 18 mm VCS is not set in
Placement data of vision components whose minimum
pitch is 0.5 mm or wider, but narrower than 0.8 mm.
*1
Placement of vision
components (0.35 <= the
smallest pitch < 0.5 mm) (Ball
components)
The optional 18 mm VCS is not set in Placement data of
vision components whose minimum pitch is 0.35 mm or
wider, but narrower than 0.5 mm.
*1
Placement of chip rise
detecting option components
The chip rise detecting unit is not available in Placement data
of the chip rise detecting option components.
Check of the maximum number
of components
The number of components exceeds the maximum number of
components which can be picked up.
Pick-up of vision components
(over 33.5 mm)
The standard VCS is not available in Pick data of vision
components whose dimension exceeds 33.5 mm.
*1
Pick-up of vision components
whose dimension is longer
than 24 mm, but 33.5 mm or
shorter.
The standard VCS or optional 37.5 mm VCS is not
available in Pick data of vision components whose
dimension is longer than 24 mm, but 33.5 mm or
shorter.
*1
Pick-up of vision components
whose dimension is longer
than 16 mm, but 24 mm or
shorter.
The standard VCS or optional VCS (37.5 mm, 27.5 mm
or 27 mm) is not available in Pick data of vision
components whose dimension is 23 mm or shorter.
*1
Pick-up of vision components
whose dimension is 16 mm or
shorter
The standard VCS or optional VCS (37.5 mm, 27.5 mm,
27 mm or 18 mm) is not available in Pick data of vision
components whose dimension is 14 mm or shorter.
*1
A coplanarity unit is enabled and a model earlier that
JVS4 is specified as the VCS in Placement data on
coplanarity option components.
*1
Pick-up of Coplanarity option
components
“Automatic selection” is selected, a coplanarity unit is
enabled and a model earlier than JVS4 is specified as
the VCS in Pick data on coplanarity option components.
*1
Pick-up of Verify option
components
The verify unit is not available in Pick data of verify option
components.
Overlap of IC collection belt
The feeder specified in Pick data is positioned over the
IC collection belt.
*1
The stick changer cannot be handled. Stick type
The number of stick changers exceeds the number of stick
changers installable.
If a stick changer is installed on the rear bank.
Component height 20 mm
The component height is not set to 20 mm in Pick data
of components whose height exceeds the standard
component height set for each station.
*1
Pick position
The system calculates the pick position of each component,
and checks to see if the calculated positions are within the
head axis movable area.
Pick data
Pick-up of general vision
components
If the specified vision processor unit is a model earlier than
JVS3 in the placement data on a general-purpose vision
component.

4 – 139
Data type Item Error conditions
The system cannot handle a bulk feeder type (BF25RS,
BF25CS, BF28RS or BF28CS).
*1
Bulk feeder type (BF25RS,
BF25CS, BF28RS, BF28CS)
There is no available bulk feeder (BF25RS, BF25CS,
BF28RS, BF28CS) when “Auto” is selected in Pick data
on a component, which is to use a bulk feeder.
*1
If an SOT direction-checking table cannot be used in the
placement data of an SOT component whose direction is
checked.
Placement of an SOT
component whose direction is
checked
(2000 series only)
– An IC recovery belt is not installed although the setting
item “Compo Reject to” of a component is set to “Trash
conveyor” and “Auto” is selected as a station in Pick data.
– An IC recovery belt is not installed although the setting
item “Compo Reject to” of a component to be picked up is
set to “Trash conveyor”.
Component Discarding
– The tray feeder (see Note) that is associated with the
component discarding destination is not installed although
the setting item “Compo Reject to” of a component to be
picked up is set to “Tray restore”, and “Auto” is selected as
a station in Pick data.
– The tray feeder (see Note) associated with the component
discarding destination is not installed although the setting
item “Compo Reject to” of a component to be picked up is
set to “Tray restore”.
– A station is set to an MTC when the setting item “Compo
Reject to” of a component is set to “Tray restore” and the
setting item “Shuttle” is set to “Mecha”.
Note: Tray feeders associated with the setting “Tray restore”
are as follows:
– MTC: TR6S, TR6D and TR4S
– MTS: TR5S and TR5D
– Tray holder: all types of tray holders
– DTS
Pick data
Overlapped with a DTS
If the area occupied by a specified feeder is overlapped with
that by a DTS.

4 – 140
Data type Item Error conditions
If the “Sequential and Mix Mode” is selected at the menu item
“2030 Mode Specification” of the “2000 Option” tab, “Use
permanent nozzle setup from MSL Setup” is selected at the
menu item “Nozzle” of the “Assignments” tab of the
“Optimization” menu, the menu item “SPLY” (supply) is all
entered to the pick data on the same component on the Pick
data screen that is associated with Component data, and a
nozzle specified on the Component data screen does not
exist on both of the stations.
Note that if a nozzle is located at either of both stations when
Pick data is set to both stations, the system will not handle
this situation as an error.
Pick data Nozzle (for a KE-2030)
If the “Sequential and Mix Mode” is selected at the menu item
“2030 Mode Specification” of the “2000 Option” tab, “Auto
arrange empty nozzle positions” is selected at the menu item
“Nozzle” of the “Assignments” tab of the “Optimization” menu,
the menu item “SPLY” (supply) is all entered to the pick data
on the same component on the Pick data screen that is
associated with Component data, and a nozzle specified on
the Component data screen does not exist on both of the
stations.
Note that if a nozzle is located at either of both stations when
Pick data is set to both stations, the system will not handle
this situation as an error.