KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第270页
4 – 163 (4) Feeder Ar range O ption W hen y ou use the “Feeder arrang e” option, you can specify the optim ization option f or assigning f eeders. Click on the “ Feeder arrang e” opt ion tab to display the f ollowing dia…

4 – 162
(3) Area Option
Optimization can specify the area that can be used to distribute feeders.
When the “Area” option is used, the feeder installation range can be switched
between the front and the rear for each program.
By installing the feeders on the feeder trolley ahead of time, you can shorten the
time until the next production start.
Click on the “Area” Option tab to display the following dialog:
Figure 4.10.1.8 Area Option
When you check the line check box, you can specify the feeder installation range
for the whole line:
Figure 4.10.1.9 Specify area in the line
Both sides Optimization assigns the feeders to both sides.
Front only Optimization assigns the feeders to front side only.
Rear only Optimization assigns the feeder to rear side only.
Front priority Optimization attempts to assign feeders to the front first, but if not
possible, feeders are assigned to the rear .
Rear priority Optimization attempts to assign feeders to the rear first, but if not
possible, feeders are assigned to the front .

4 – 163
(4) Feeder Arrange Option
When you use the “Feeder arrange” option, you can specify the optimization
option for assigning feeders.
Click on the “Feeder arrange” option tab to display the following dialog box:
Figure 4.10.1.10 Feeder Arrange Option
Placement peak
Specify the starting point for assigning feeders. The choices are:
• Medium point of placement: Arranges feeder in the median (center) of placement
points
• Average point of placement: Arranges feeder in the average point of placement
points
Note: When you check the check box “Arrange feeders according to the placement
peak point is fixed on center of the PWB” on the “2000” option dialog box, this
item is disabled for a KE-2000 series of station.

4 – 164
(5) Place Order Option
When you use the “Place order” option, you can specify the optimization option for
deciding the pick-up/placement order of components.
Figure 4.10.1.11 Place order option
Data order
Specify the placement data order in the station format that is divided and created by
the Optimization utility.
Figure 4.10.1.12 Data
• Assign in input order of Production Program File
This is the order that the Optimization utility assigned the placement data at
division.
• Assign in optimized order
The optimization order becomes the input order of Placement data.