KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第275页
4 – 168 − Primar y Secondary Select which side to be used mainly in Non-Stop operation m ode, f ront or r ear . • Front to Rear: T he system performs PWB production w ith the front side mainly , and uses the rear side wh…

4 – 167
(7) Non-stop operation
You can use the Optimization function to specify a station that is to perform the
Non-stop operation. When you use this option, you can replace components
without stopping the current production.
When you select the “Non-stop” tab, the following dialog box appears on the
screen.
Figure 4.10.1.17 “Non-stop” option tab
− When you check the check box “Line”, you can specify the Non-stop operation.
Figure 4.10.1.18 Specifying the Non-stop operation
− Feeder
Set the Non-stop operation of a feeder.
• No: The Optimization utility does not perform the Non-stop
operation.
• Tact priority: The Optimization utility assigns components with considering
the tact first.
• Arrange priority: The Optimization utility assigns components with considering
the feeder changeover first.
When you select “Arrange priority” with a KE-2020, an error occurs if the
system executes the line coherence check.
4 – 168
− Primary Secondary
Select which side to be used mainly in Non-Stop operation mode, front or rear.
• Front to Rear: The system performs PWB production with the front side mainly,
and uses the rear side when you replace components.
• Rear to Front: The system performs PWB production with the rear side mainly,
and uses the front side when you replace components.
− MTC/MTS
Select whether to allow an MTC and MTS to perform the Non-stop operation or
not.

4 – 169
4.10.2 Divided Placement Data
This command displays Placement data which is distributed to each station by the
Optimization utility. Select the menu command [Divided Placement Data] from the
“Optimization” menu. A submenu from which you can select stations displays. Select
a station whose data is to be displayed.
Figure 4.10.2.1 Divided Placement Data selection menu
Notes:
①
This menu cannot be selected if optimization has not been performed
(the divided files do not exist), or if the production program has been
changed after optimization.
②
The system can display Divided Placement data in two orders: input
order and optimization order. Select the menu command [File], and then
[Environment setting] command on the “File” menu to select the order.
•
When you select the input order, the system displays all Placement
data in input order.
•
When you select the optimization order, the system displays only the
Placement data that is used to place components in optimized
placement order with considering the optimization result.
When you select a station on the station selection dialog box, the corresponding
window appears on the screen as shown below.
Figure 4.10.2.2 Divided Placement Data Display Example (Input Order)