4 – 172 4.10.4         Component supply count Specify the number of com ponents to be supplied which can be assigned by the Optimization utilit y . By using two or more com ponents (reel or tray), t he productivi…

100%1 / 1361
4 – 171
The following window displays after a station is selected:
Figure 4.10.3.2 Nozzle Layout Display Example
Perm. Nozzle (Permanent nozzle):
Nozzle layout which is set on the Machine setup menu.
( * mark indicates the vacuum calibration.)
Opt. Nozzle (Optimized nozzle):
Nozzle layout which is output with the Optimization utility.
( * mark indicates the vacuum calibration.)
No. of Nozzles:
Number of nozzle resources (Resource), the number of nozzles set as
the permanent information (Perm. Info) and the number of nozzles output
with the Optimization utility (Opt.) are displayed here.
Close: Quits the Nozzle layout dialog box.
Enabled for
KE-2030 onl
y
4 – 172
4.10.4
Component supply count
Specify the number of components to be supplied which can be assigned by the
Optimization utility. By using two or more components (reel or tray), the productivity
can be improved.
Figure 4.10.4.1 Component supply count command
When the [Component supply count] menu command is selected, the following dialog
box displays:
Figure 4.10.4.2 Component supply count dialog box example
The detailed descriptions of each item displayed on the Component supply count
dialog box are shown below:
Figure 4.10.4.3 Component supply count dialog box details
Component name
included in the
program
Displays the number of feeders output
by the Optimization utility or the
number of feeders manually assigned
Indicates that the Optimaization
utility is to set the number of
feeders automatically.
When specified manually, it
displays “—“
4 – 173
(1) Changing the “Component supply count” setting
To change the “Component supply count” setting, select the line of a component
whose quantity is to be changed, then click the <Change> button or double click
the line of a component.
The dialog box appears on the screen as shown below. Enter the number of
components to be supplied.
Figure 4.10.4.4 “Change supply” dialog box example
Auto The number of the components selected to be supplied is
automatically set. The Optimization utility optimizes the number of
feeders so that it can be within the upper limit of available resources
(number of nozzles and feeders). The number of reels or trays for
available components is assumed not to be restricted.
Manual Manually change the number of components to be supplied. The
Optimization utility assigns feeders or trays according to the specified
number of components. Note that a feeder of which placement point
has not been assigned is deleted, so the number of components may
be less than the specified number.
Select the edit box, then enter a number directly from a keyboard, or click either of the
arrow buttons next to the edit box to set it.
Figure 4.10.4.5 Example for manually setting the number of components to be supplied