1 − 13 (10) Environmental condi tions Operating Ambient temperat ure: +10 ° C to +35 ° C Relative humidity: 50% or less (at 35 ° C) 90% or less (at 20 ° C) Transport and storag e Temperat ure: - 25 ° C to +70 ° C Relativ…
1 − 12
(3) Least input placement angle increment
Programmable placement angle setting unit: 0.05°
(4) Automatic tool changer (ATC)
The ATC can accommodate up to 23 nozzles.
(5) Transport rail height
900 mm ± 20 mm
(6) Machine dimensions and mass
W : [KE-2010M] 1300 mm
[KE-2010L] 1300 mm
[KE-2010E] 1300 mm
[KE-2010M] 1400 mm (including PWB transfer unit)
[KE-2010L] 1400 mm (including PWB transfer unit)
[KE-2010E] 1730 mm (including PWB transfer unit)
D : [KE-2010M] 1471mm
[KE-2010L] 1599 mm
[KE-2010E] 1705mm
[KE-2010M] 1656 mm (including keyboard)
[KE-2010L] 1784 mm (including keyboard)
[KE-2010E] 1890 mm (including keyboard)
H : [KE-2010M] 1550 mm
(height of the main unit when the PWB transfer height is 900
mm)
[KE-2010L] 1834 mm
(height of the vision monitor when the PWB transfer height is 900
mm)
[KE-2010E] 2200 mm
(height of the signal tower when the PWB transfer height is 900
mm)
Mass: [KE-2010M] 1400 kg
[KE-2010L] 1410 kg
[KE-2010E] 1510 kg
(7) Air requirements
Air pressure : 0.49 ± 0.05 Mpa
Air consumption : 200 L/min.(ANR)
Dry air : Atmospheric dew point -17°C or lower
(8) Noise level
80dB
(9) Country of manufacturing
Manufactured in Japan
1 − 13
(10) Environmental conditions
Operating
Ambient temperature: +10° C to +35° C
Relative humidity: 50% or less (at 35° C)
90% or less (at 20° C)
Transport and storage
Temperature: -25° C to +70° C
Relative humidity: 20% to 95% (No condensation)
(11) Installation category: Installation category II (IEC664-1)
(12) Pollution degree: Pollution degree II (IEC664-1)

1 − 14
1.1.5 Electrical specifications
(1) Number of placement points
Up to 3,000 placement points can be defined per program.
For multi-matrix PWBs, up to 10,000 points can be defined, which is the number
of circuits multiplied by the number of placement points.
(2) Control Systems
Table 1.1.5.1
Item Control system Resolution
X-Y
Z
θ (head)
Closed loop by AC servo motor
Semi-closed loop by AC servo motor
Semi-closed loop by AC servo motor
0.005mm
0.00125mm
0.02°
(3) Main CPU
Pemtium
(4) Display
Character display : 10.4" color (TTF liquid crystal display panel)
Graphics display : 9" monochrome
(5) Data and program input/output
A program which has been generated with an external programming device or
manually created from the keyboard can be input by means of a 3.5" floppy disk.
(2HD/1.44 MB type only)
When the machine is connected to a host line computer, the LAN interface
permits high-speed communications.
(6) Printer interface
Centronics interface
(7) Power requirements
Voltage : Three-phase, 200 V, 220 V, 240 V
(for Japan)
200 V, 220 V, 240 V, 380 V, 400 V, 415 V
AC
(for the machines to be exported)
Allowable voltage range: ± 10 % (for the rated voltage)
Apparent power : 3 kVA
Frequency : 50/60 Hz
Size of the primary-side power cable : 6 mm
2
or more
Size of the protective grounding lead wire : 6 mm
2
or more
(8) UPS
This machine is equipped with the uninterruptible power supply (UPS) to prevent
data from being damaged or lost due to power failure.
Batteries are used as the back-up power supply of the UPS, so the UPS is
designed to stop the system before these batteries run down. Therefore, even
during power failure, the system can be terminated safely so that any data cannot
be damaged or lost even when a power failure occurs.