KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第421页

6 − 45 ② LA recogn ition Value Error contents Value Error contents 64 No component 93 A component is too small for the system to decide its angle that is used for determining its width. 65 The M CM processor cannot respo…

100%1 / 1361
6 44
28 Fine-pitch lead detection error 61 All balls recognition error (Ball recognition
error [dimmed or dark])
29 The number of detected leads is less than the
specified number.
(Extended-lead connector)
62 All balls recognition error (The ball top and
bottom sides inclining error [three degrees or
more])
30 The number of detected leads is more than
the specified number.
(Extended-lead connector)
63 All balls recognition error (The ball left and
right sides inclining error [three degrees or
more])
40 Ball outer frame recognition error (Top side
ball detection error [Detection result: less
than 1/3])
64 All balls recognition error (Distance between
the top and bottom sides on which balls are
located is wide [half-pitch])
65 All balls recognition error (The distance
between the right and left sides on which ball
are located is wide [half-pitch])
107 Multi-lead recognition error (Impossible
positioning)
66 All balls recognition error (Ball inspection
area creating error)
108 Multi-lead recognition error (Lead detection is
impossible.)
67 All balls recognition error (Ball deformation
inspection error)
120 Random ball recognition error (Ball pitch
error)
68 All balls recognition error (Ball diameter
inspection error)
121 Random ball recognition error (Ball
deformation inspection error)
69 All balls recognition error (Ball brightness
error)
122 Random ball recognition error (Ball diameter
inspection error)
70 All balls recognition error (Ball existence
inspection error)
123 Random ball recognition error (Ball existence
inspection (diameter) error)
80 Outline recognition error (No component) 124 Random ball recognition error (Ball existence
inspection (intensity) error)
81 Outline recognition error (Component size
error)
125 Random ball recognition error (Ball existence
inspection (intensity) error: the number of
samples is not enough.)
82 Outline recognition error (There is no target
pattern in the inspection frame.)
140 Ball inspection error (Ball detection error)
83 Outline recognition error (IC mark inclining
error [one degree or more])
141 Ball inspection error (Matrix size error)
84 Outline recognition error (Distance between
the top and bottom marks or right and left
marks is wrong. [+ 0.5 mm or wider])
142 Ball inspection error (Number of balls error)
85 Outline recognition error (OFC component
recognition error)
143 Ball inspection error (Ball diameter error)
100 Multi-lead recognition error (Bent lead) 144 Ball inspection error (Intensity reference
obtaining error)
101 Multi-lead recognition error (Lead length
error)
145 Ball inspection error (Intensity characteristics
error)
102 Multi-lead recognition error (Lead pitch error) 160 Outline measurement error (Component is
tilted too much.)
103 Multi-lead recognition error (The number of
detected leads is less than the specified
number.)
161 Outline measurement error (Dimensions are
too large.)
104 Multi-lead recognition error (The number of
detected leads is more than the specified
number.)
162 Outline measurement error (Dimensions are
too small.)
105 Multi-lead recognition error (No detected
lead)
163 Outline measurement error (No component)
106 Multi-lead recognition error (The number of
detected leads is one to three.)
999 Other recognition error
6 45
LA recognition
Value Error contents Value Error contents
64 No component 93
A component is too small for the system to
decide its angle that is used for determining
its width.
65
The MCM processor cannot respond to
measurement.
94
An error occurs while the system is
calculating the angle.
67
The MCM received a command that aborted
measurement.
95
An error occurs while the system is
calculating the angle.
70
The firmware detected the state that could
not be generated.
96
An error occurs while the system is
calculating the angle.
75
The system found the previous peak
detection error while it was detecting the
next peak.
98
The system could not detect the angle used
for determining the minimum width within the
limit angle.
77
Sufficient contrast for the system to detect
the margin of a component cannot be
obtained.
99
The system detected the process over-run
error.
78
An error occurs indicating that a small
window, 2000 micron or less, is specified.
103
The system detected an error indicating that
the intensity was too low to check the image
of a component.
79
The system detected a blocked window
state.
104
The system detected an error indicating that
region boundary for checking the image of a
component was not set correctly.
80
The system detected an error indicating that
the leftmost window was blocked.
105
The system failed to check the image of a
component.
81
The system detected an error indicating that
the rightmost window was blocked.
106
The system detected the error level not
regulated.
82
The system detected an error indicating that
the both left and right window edges were
blocked.
207 Chip rise
90
An error occurs while the system is
calculating the angle.
208 Wrong dimensions of a component
91
An error occurs while the system is
calculating the angle.
209 Component direction error
92
An error occurs while the system is
calculating the angle.
210 Feeder pitch gap
Component
Value Error contents Value Error contents
1 Chip standing 17 Placement check error
2 Component fall 33 LLL Colinearity
3 Verify error 34 LLL Coplanarity
7 Unplaced 35 LLL lead count
8 Other component 36 LLL compo pos.
9 Pick miss
10 Ball inspection
16 Illegal component junk
Feeder unit type
Value Error contents Value Error contents
1 Run out of components
6 46
MTC
Value Error contents Value Error contents
1 Command error 73 Over run error(Y + limit)
2 Parameter error 74 No.2 Head error
3 No component 75 Over Run Shuttle
4 READY time out 78 Y Holder Error
5 ETX time out 79 Not finish initialize
6 Sync char time out 80 Mounter emergency stop
7 Response time out 81 Over run eror(Z - limit)
8 Data error 82 Over run eror(X - limit)
9 Rspns error 83 Over run eror(Y - limit)
10 Request at offline 84 No.1 Head Sensor error
13 Stacker Lock 85 Over run eror( Shuttle )
14 Picking error 86 Interlock error
15 Picking error(shuttle) 91 Z error
16 Not recovery component 92 X error
18 Could not detect tray 93 Y error
19 Cover open 94 No.2 Head Sensor error
24 Transport error(head) 95 Shuttle error
25 Transport erorr(shuttle) 99 Door, Cover SW
26 Supply 100 Overrun error
28 No Stacker 101 Z axis sensor error
29 Door open 102 X axis sensor error
30 Component remain 103 Y axis sensor error
35 BGA Holder error 107 RAM error
36 Detecting Board on the Conveyor 108 Illegal break current
40 Receive pick finish during shuttle
transporting
109 Holder Sensor error
44 Head Vaccum No.1 Sensor 110 Motor Off
45 Shuttle Vaccum No.1 Sensor 111 Sensor error(Z + limit)
46 Failed to detect Origin Auto PWB Conveyor 112 Sensor error(X + limit)
48 Teaching spot turned off 113 Sensor error(Y + limit)
49 MS parameter not entered 115 Shuttle sensor error
54 Head Vaccum No.2 Sensor 117 NV-RAM error
55 Shuttle Vaccum No.2 Sensor 118 Close/open sensor error
56 Detecting Motor Error Auto PWB conveyor. 122 Driver Alarm(X)
61 Home position error(Z) 123 Driver Alarm(Y)
62 Home position error(X) 125 Driver Alarm(shuttle)
63 Home position error(Y) 128 Tray Error.
64 No.1 Head Error 135 Change error(shuttle pad)
65 Shuttle error 141 Impossible servo driver on(Z)
68 Shutter close error 145 Soft Limit (Shuttle)
69 Shutter open error 151 Servo alarm
70 Emergency stop 165 Bulb bad motion
71 Over run error(Z + limit) 171 Request cancell
72 Over run error(X + limit) 182 Switch Off-line