KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第442页

6 − 66 * The actually displayed names under the capt ion “Head” on the scr een shown in Figure 7. 4.1.4 vary depending on the m odel you use. Model Head names KE-2010 L1 to L4 KE-2020 L1 to L4, R1 KE-2030 L1 to L4, R1 to…

100%1 / 1361
6 65
(3) Tracking and pick position correction of a feeder where components run out
Feeders to be tracked
The system can track a tape feeder, stick feeder, and bulk feeder; all feeders
where a retry over error occurs or components run out. However, it does not
track a feeder which is set as "Unused".
How to enter Tracking mode
Press one of the CAMERA, HEAD and HMS device keys of the HOD to
activate its function.
Other operation
The other operations during this tracking and correction are the same as
those for pick position tracking.
(4) Detailed information
When you click the <Detail> button, the system displays the list of the heads that
cause an error.
Figure 7.4.1.3 “Error Detail” dialog box (Screen example when you use a KE-2020)
6 66
* The actually displayed names under the caption “Head” on the screen shown
in Figure 7.4.1.4 vary depending on the model you use.
Model Head names
KE-2010 L1 to L4
KE-2020 L1 to L4, R1
KE-2030 L1 to L4, R1 to R4
KE-2040 L1, R1
The errors actually displayed under the caption “Error” are the same as those
of a Retry list.
The detailed description of errors actually displayed under the caption “Detail”
is the same as that of a Retry list.
<OK>: When you click this button, the “Error Detail” dialog box closes.
<START>: When you press this button, the “Error Detail” dialog box and the
component run-out dialog box close and the system resumes
production.
<STOP>: When you press this button, the “Error Detail” dialog box closes, and
the dialog box displayed when you try to abort production opens to
ask you whether to abort production actually.
Obtaining the coplanarity information (available with a KE-2020/2040 only)
If a coplanarity error occurs, the <Copla Info.> button appears on the “Error
Detail” dialog box.
Figure 6.4.1.5 <Copla Info.> button
When you click this button, the machine obtains the coplanarity information and
shows it on the memo pad.
When you click the line of the head on which a coplanarity error occurs with the
right button, the “Copla Info” pop-up menu appears on the screen.
When you click the corresponding command from this pop-up menu, you can
obtain the coplanarity information and display it on the memo pad also.
If the “Pause” dialog box appears on the screen due to a coplanarity error, this
pop-up menu appears also.
6 67
1) Output format of the coplanarity information
The example of the output coplanarity information is shown below.
[See the next page for descriptions of the format.]
Reference No.
CoplaResults
wHead=7,wNozzle=508,wATCNo=8,wCompoType=102,wCompoIdx=0,wErrorCode=1
No,Judge,lX,lY,lZ,nZCop,nZCol
0,0,2.188,-4.000,0.067,-0.033,0.000
1,0,1.878,-4.000,0.074,-0.026,0.000
2,0,1.608,-4.000,0.068,-0.032,0.000
3,0,1.300,-4.000,0.064,-0.035,0.000
70,0,-11.878,6.160,0.069,-0.030,0.000
71,0,-11.875,6.450,0.062,-0.037,0.000
72,0,-11.878,6.750,0.067,-0.033,0.000
111,0,-1.975,11.880,0.080,-0.026,0.000
112,1,-1.683,11.870,-0.010,-0.129,0.000
113,0,-1.380,11.870,0.072,-0.034,0.000
165,0,3.940,-1.620,0.082,-0.020,0.000
166,0,3.945,-1.940,0.074,-0.028,0.000
167,0,3.940,-2.230,0.081,-0.020,0.000
2) Descriptions of the output format
Header information (fixed character string)
Measurement requirements data
wHead=7 Head information (L1=3, R1=7)
wNozzle=508 Nozzle number
wATCNo=8 ATC hole number
wCompoTYpe=102 Component type number (192, …., QFP)
wCompoIdx=0 Component number
wErrorCode=1 Coplanarity error number
(1: coplanarity error, 2: terminal positioning error,
3: number of leads error, 4: colinearity error,
5: measurement error)
Measurement requirements data may be expanded without notice.
Format