6 − 67 1) O utput f orm at of the coplanarit y informat ion T he example of t he output coplanar ity inform ation is shown below. [See th e nex t page for descrip tions of the format.] Refer ence No. CoplaResu lts ① wHea…

100%1 / 1361
6 66
* The actually displayed names under the caption “Head” on the screen shown
in Figure 7.4.1.4 vary depending on the model you use.
Model Head names
KE-2010 L1 to L4
KE-2020 L1 to L4, R1
KE-2030 L1 to L4, R1 to R4
KE-2040 L1, R1
The errors actually displayed under the caption “Error” are the same as those
of a Retry list.
The detailed description of errors actually displayed under the caption “Detail”
is the same as that of a Retry list.
<OK>: When you click this button, the “Error Detail” dialog box closes.
<START>: When you press this button, the “Error Detail” dialog box and the
component run-out dialog box close and the system resumes
production.
<STOP>: When you press this button, the “Error Detail” dialog box closes, and
the dialog box displayed when you try to abort production opens to
ask you whether to abort production actually.
Obtaining the coplanarity information (available with a KE-2020/2040 only)
If a coplanarity error occurs, the <Copla Info.> button appears on the “Error
Detail” dialog box.
Figure 6.4.1.5 <Copla Info.> button
When you click this button, the machine obtains the coplanarity information and
shows it on the memo pad.
When you click the line of the head on which a coplanarity error occurs with the
right button, the “Copla Info” pop-up menu appears on the screen.
When you click the corresponding command from this pop-up menu, you can
obtain the coplanarity information and display it on the memo pad also.
If the “Pause” dialog box appears on the screen due to a coplanarity error, this
pop-up menu appears also.
6 67
1) Output format of the coplanarity information
The example of the output coplanarity information is shown below.
[See the next page for descriptions of the format.]
Reference No.
CoplaResults
wHead=7,wNozzle=508,wATCNo=8,wCompoType=102,wCompoIdx=0,wErrorCode=1
No,Judge,lX,lY,lZ,nZCop,nZCol
0,0,2.188,-4.000,0.067,-0.033,0.000
1,0,1.878,-4.000,0.074,-0.026,0.000
2,0,1.608,-4.000,0.068,-0.032,0.000
3,0,1.300,-4.000,0.064,-0.035,0.000
70,0,-11.878,6.160,0.069,-0.030,0.000
71,0,-11.875,6.450,0.062,-0.037,0.000
72,0,-11.878,6.750,0.067,-0.033,0.000
111,0,-1.975,11.880,0.080,-0.026,0.000
112,1,-1.683,11.870,-0.010,-0.129,0.000
113,0,-1.380,11.870,0.072,-0.034,0.000
165,0,3.940,-1.620,0.082,-0.020,0.000
166,0,3.945,-1.940,0.074,-0.028,0.000
167,0,3.940,-2.230,0.081,-0.020,0.000
2) Descriptions of the output format
Header information (fixed character string)
Measurement requirements data
wHead=7 Head information (L1=3, R1=7)
wNozzle=508 Nozzle number
wATCNo=8 ATC hole number
wCompoTYpe=102 Component type number (192, …., QFP)
wCompoIdx=0 Component number
wErrorCode=1 Coplanarity error number
(1: coplanarity error, 2: terminal positioning error,
3: number of leads error, 4: colinearity error,
5: measurement error)
Measurement requirements data may be expanded without notice.
Format
6 68
Detailed information
Lead number, measurement result, X-coordinate, Y-coordinate, Z-coordinate,
coplanarity value and colinearity value are shown here.
The lead numbers are assigned sequentially from “0”.
The measurement result “1” indicates that an error was detected at the
lead.
Coordinates are output in mm.
The X-coordinate and Y-coordinate are relative coordinates viewed from
the center of a component.
The Z-coordinate, coplanarity value and colinearity value indicate the
reference position viewed from the lead height. (If the lead height is
higher than the reference position, a negative value is output.)
Each item of the detailed information is output in order independent of the
measurement posture, and the bottom side, right side, top side and of the left
side of component data are output in this order.
If a coplanarity error occurs, only a coplanarity value is set but a colinearity
value is not set. If a colinearity error occurs, only a colinearity value is set.
A Z-coordinate is always output.
CAUTION
The head starts to move immediately after the "Retry" button is selected
or the "Skip" button is selected, and the <START> switch is pressed.
Then the machine restarts PWB production.
To avoid a risk of injury, do not place your hand in the machine, nor
move your face or head close to the machine during operation.
Before pressing the <START> switch, check that there is no one who is
working in the machine.
Before pressing the <START> switch check that there is no one who
can be injured when the head starts to move.
Before pressing the <START> switch, check that there are no obstacles
(tools and jigs) attached or left in the machine.
Even when "Stop production after ejecting PWB" is selected, X and Y
axes and the head continue to move to replace nozzles.
To avoid a risk of injury, do not place your hand in the machine, nor
move your face or head close to the machine even after stopping the
production.