KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第572页

7 − 35 7.2.2.10. 3 Function Device enabl e A screen appears as shown in Figure 7.2. 2.10.3 “ Function Device enable setting” dialog box appears when the [Function Device enable] tab is selected W hen "M TS" is …

100%1 / 1361
7 34
(3) Production operation
Table 7.2.2.10.2 Placement when a unit is set as “Unused”
No. Unit Production operation
1 Feeder positioning indicator
(front, rear)
This function is disabled but placement of components is carried out.
2 Feeder trolley
(front, rear)
KE2010,2020,2040
(front L, front R, rear L, rear R)
KE2030
This function is disabled but placement of components is carried out.
3 IC Conveyor belt
(front, rear) (Not available for a
KE-2030)
This function is disabled but placement of components is carried out.
4 Bad mark sensor This function is disabled but placement of components is carried out.
5 Shape clamp Offset adjustment of the mark position when mark is used or of the
placement point when mark is not used is not carried out.
Offset adjustment is made by referring to the mark for placement
when mark is used.
6 Auto-width conveyor This function is disabled but placement of components is carried out.
7 Component verification The machine does not perform the component verification function
even though this function is designated.
8 Coplanarity Placement is carried out without performing coplanarity even when
component coplanarity is designated.
9 HMS This function is disabled but placement of components is carried out.
10 Mini signal light This function is disabled but placement of components is carried out.
11 Vacuum table This function is disabled but placement of components is carried out.
7 35
7.2.2.10.3 Function Device enable
A screen appears as shown in Figure 7.2.2.10.3 “Function Device enable setting”
dialog box appears when the [Function Device enable] tab is selected
When "MTS" is selected on the "MTC/MTS Device enable" dialog box, the menu
items are changed to "Bank mark Recognition [Rear (MTS)]".
Figure 7.2.2.10.3 Function Device enable setting dialog box
(1) Setting items
No. Item Description
1 Function Device enable Function to be used/not used
If the production program requires the functions above to place components
on a board successfully, and you specify them as “unused”, see Table
7.2.2.10.3 which shows whether components are placed actually.
Limitations put on operations of the machine if you check any of check boxes
of the “Optimization function” group are described in Table 7.2.2.10.4.
(2) Setting the unit
Specify the device unit to be used with the check box.
Any unit without option setting being made as the MS parameter cannot be
checked.
Zeroing is necessary again when changing the head status from as not to be
used.
Back Master-Bank [Non-stop]
Specifies the position of the master bank during Non-stop operation.
You can specify this setting regardless of the PWB transport reference
side.
The setting of the check box “Alternate” on the “Function enable” tab
invoked from the Operation option dialog box is preferred.
7 36
(3) Production operation
Table 7.2.2.10.3 Placement when set to “Unused”
No. Unit Production operation
1 Stops by detected
feeder float
The XY speed becomes slower when the sensor detects feeder floating while
the XY axe are moving.
When the sensor detects feeder floating before the XY axes moves, the
machine asks the operator whether to retry the sensor detection operation.
When the operator selects “Retry”, the sensor reconfirms feeder floating.
When he or she selects “Cancel”, the production is terminated.
2 Bank mark Recognition
(front, rear)
The function is disabled but placement of components is carried out.
3 SOT Inspect Stage You cannot specify the SOT direction check on the tracking menu.
4 Back Master-Bank
[Non-stop]
Places the master bank on the front (“Front” means the front side of the main
unit.).
Table 7.2.2.10.4 Placement operation to be performed if you check any of the
check boxes of the “Optimization function” group
No. Unit Production operation
1 Disable feeder
optimization
The “Pick Data” option displayed on the dialog box that appears when you
execute the [Optimization] command on the “Optimization” menu of the
Program Editor utility is fixed to “Auto assign all data”. You cannot select
any other option.
2 Disable nozzle
optimization
The “Nozzle” option displayed on the dialog box that appears when you
execute the [Optimization] command on the “Optimization” menu of the
Program Editing utility is fixed to “Use permanent nozzle setup from MSL
Setup”. You cannot select any other option.