KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第584页

7 − 47 Figure 7.2. 2.15.2 "Threshold - I nitiali ze" dialog box Figure 7.2.2. 15.3 "Threshold - Execution" dialog box

100%1 / 1361
7 46
7.2.2.15 Bad mark sensor teaching
When you select the setting item "Bad mark sensor teaching", the "Bad mark
sensor teaching" dialog box appears on the screen as shown in Figure 7.2.2.15.1.
Figure 7.2.2.15.1 "Bad mark sensor teaching" dialog box
(1) Setting items
No. Item Description
1 Snsr. ON Position Sets the sensor turning ON position.
2 Snsr. OFF Position Sets the sensor turning OFF position.
(2) How to set
Enter the X- and Y-coordinates separately directly from a keyboard.
Use the HOD to teach the coordinates with a camera.
In this case, both X and Y values are loaded at the same time regardless of
the input focus position.
(3) Actions taken after you click the <DONE> button
When you click the <DONE> button, the "Threshold - Initialize" dialog box
appears on the screen, then the system initializes the bad mark sensor.
Next, the "Threshold - Execution" dialog box appears on the screen which
indicates the system automatically performs the teaching operation.
7 47
Figure 7.2.2.15.2 "Threshold - Initialize" dialog box
Figure 7.2.2.15.3 "Threshold - Execution" dialog box
7 48
7.2.2.16 Coplanarity
You have to set the following menu item on the “Option Device enable” tab
shown in Figure 7.2.2.10.2.
Check to see if you check the check box “Coplanarity” in the “Others”
column.
Select the [Setup] command from the menu bar, and the [Machine setup] command.
Next, select the [Setting Group] command on the “Machine setup” menu, then the
[Coplanarity] command. The “Coplanarity” setting dialog box appears on the
screen as shown in Figure 7.2.2.16 (available to a KE-2020/KE-2040 only).
Figure 7.2.2.16 “Coplanarity” setting dialog box
For a ball component: the system measures this type of component in the
least squares method regardless of the setting of the menu item “Measure
plane.”
For a unidirectional lead connector: the system measures only colinearity
of this type of component in the least squares method regardless of the
setting of the menu item “Measure plane.”
(1) Setting items
No. Item Description
1 Number of Retry Sets the number of a retry operation to be done for a coplanarity check.
2 Measure plane Sets the reference plane used for a coplanarity check.