8.2.2 Head device control
When you select the [Head] command on the [Ctrl] menu, then the [Head device
control] command, the following Head device control dialog box appears on the
screen.
Figure 8.2.2 Head device control dialog box
(1) Control unit
Select the unit to be controlled from the combo box.
You cannot select any unit which is not checked (not installed) at the “Option”
setting of the MS parameters.
This selection does not affect the setting of the “Device enable” menu invoked
from the Machine Setup menu. (This means that the units not checked (not
used) can be used.)
The following list appears when you press the ALT key and the down arrow key
at the same time.

8 − 14
(2) Control item
Select the control item with the corresponding radio button.
The available radio buttons used for selecting control items vary depending on
the control unit you selected.
① OCC
② Bad mark sensor
③ HMS
(3) Control button
Each control item can be executed with the corresponding control button.
The display of the control button varies depending on the selected control item.
① Operation when you select “OCC” as the control unit
1) XY move
Operate the XY axes in the same manner as described under the
section “Head control”.

8 − 15
2) Light cont.
The control item “Light cont.” turns on and /or off the OCC light.
When the control item “Light cont.” is checked, click one of the <ON>,
<OFF> and <ON/OFF> buttons, or press one of the F3, F4 and F5
keys.
When the control item “Light cont.” is checked and you click the
<SET> button or press the F6 key, the Light setting dialog box appears
on the screen.
Figure 8.2.3 Light setting dialog box
3) Bright.
Move the slide bar to set the amount of light.
With the arrow keys, PgUp key, or PgDn key, you can move the slide
bar.
When you click the <OK> button, the light of the amount specified
turns on the next time.
When you click the <CANCEL> button, your setting becomes invalid.
The light state display is updated when the light is controlled
completely.
4) Polarity control
The control item “Port. cont.” controls positive and negative of the
polarity of the OCC.
When the control item “Port. cont.” is checked, click one of the
<Positive>, <Negative>, and <Positive/Negative> buttons, or press one
of the F3, F4 and F5 keys.