KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第620页

8 − 31 (1) Con trol item Select a control it em with the corresponding radio butt on. (2) Contr ol position W ith the radio button select t he position when the conveyor is automatically controlled. Y ou cannot select th…

100%1 / 1361
8 30
8.3.2 Transport system automatic control
When you select the [Conveyor] command on the [Ctrl] menu, then the [Automatic
control of conveyor] command, the following “Automatic control of conveyor” dialog
box appears on the screen.
Figure 8.3.2 Automatic control of conveyor dialog box
(Screen example when a KE-2030 is used)
Note: *1 The Control item “PWB move and clamp” and the menu items
“Between PWB Station moving” and “Control position” are
displayed with a KE-2030 only.
*1
*1
*1
*1
8 31
(1) Control item
Select a control item with the corresponding radio button.
(2) Control position
With the radio button select the position when the conveyor is automatically
controlled.
You cannot select the control position if the control item, “Initialization”, “PWB
ejection”, “PWB release” or “PWB check at WAIT/OUT snsr.” is selected.
(3) Between PWB Station moving
Select either of the two radio buttons: whether to move the conveyor between
the PWB stations or not.
You cannot select this menu item if the control item “Initialization”, “PWB
ejection” or “PWB release” is selected.
Note: You cannot select this menu item for models other than a KE-2030.
8 32
(4) Control position
With the corresponding radio button, select the position to be used when the
transport system is automatically controlled.
This item is not available when you select “Initialization” as the control item.
Note: "2 station" cannot be set with a model other than a KE-2030.
(5) Control button
Each control button executes the associated control item.
1) Initialization
This item initializes the PWB transport operation operation.
When the control item “Initialization” is checked, select the <EXEC> button,
or press the F3 key to control the initialization.
2) PWB load
This item loads a PWB according to the setting of "Positioning method".
When the control item “PWB load” is checked, select the <EXEC> button,
or press the F3 key to control the PWB loading.
3) PWB ejection
This item ejects a PWB.
When the control item “PWB ejection” is checked, select the <EXEC>
button, or press the F3 key to control the PWB ejection.
4) PWB release
This item releases a clamped PWB.
When the control item “PWB release” is checked, select the <EXEC>
button, or press the F3 key to control the PWB release.
5) PWB re-clamp
This item re-clamps a board located on the PWB transport path according
to the “Positioning method” selected.
When the control item “PWB re-clamp” is checked, select the <EXEC>
button or press the F3 key to control the PWB re-clamping function.