KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第624页

8 − 35 ① T he following four kinds of st ation status are as sum ed when the m achine trans ports a board from lef t to right. 1. There is no board on both the IN station and OUT station. 2. A board is loaded onto the IN…

100%1 / 1361
8 34
Note: You cannot set this menu item for models other than a KE-2030.
Between
PWB
Station
moving
Control
position
Status of the
machine before
loading a PWB
(IN station/OUT
station)
PWB
ejection
Conveyor moving
between the PWB
stations
PWB
loading
Remarks
1 (None/ None)
None
C (Both stations)
2 (Existing/None) I (IN station) C (Both stations)
3 (None /Existing) II (OUT station) C (Both stations)
2 station
4 (Existing/Existing) III (Both
stations)
C (Both stations)
1 (None/ None)
None
A (IN station)
2 (Existing/None) I (IN station) A (IN station)
3 (None /Existing) None
A (IN station) (Note 3)
IN station
4 (Existing/Existing) III (Both
stations)
A (IN station)
1 (None/ None)
None
B (OUT station)
2 (Existing/None) I (IN station) B (OUT station)
3 (None /Existing) II (OUT station) B (OUT station)
Don’t
Move
OUT station
4 (Existing/Existing) III (Both
stations)
The conveyor does not
move.
B (OUT station)
1 (None/ None)
None
The conveyor does not
move.
A (IN station) (Note 4)
2 (Existing/None) None
The conveyor moves.
A (IN station) (Note 1)
3 (None /Existing) II (OUT station)
The conveyor does not
move.
A (IN station)
2 station
4 (Existing/Existing) II (OUT station)
The conveyor moves.
A (IN station) (Note 2)
1 (None/ None)
None
The conveyor does not
move.
A (IN station)
2 (Existing/None) None
The conveyor moves.
A (IN station) (Note 1)
3 (None /Existing) None
The conveyor does not
move.
A (IN station) (Note 3)
IN station
4 (Existing/Existing) II (OUT station)
The conveyor moves.
A (IN station) (Note 2)
1 (None/ None)
None
The conveyor does not
move.
B (OUT station)
2 (Existing/None) None
The conveyor moves.
None
3 (None /Existing) II (OUT station)
The conveyor does not
move.
B (OUT station)
Move
OUT station
4 (Existing/Existing) II (OUT station)
The conveyor moves.
None
Existing: There is a PWB on the station.
None: There is not any PWB on the station.
1 to 4:
Status of the machine before
loading a PWB (see the next page)
I to III:
PWB ejection (see the next page)
A to C:
PWB loading (see the next page)
Note 1: A PWB located on the IN (entrance) station is moved onto the OUT (exit) station (see
3 on the next page) at the same time a PWB is loaded onto the IN station (see 4-A
on the next page).
Note 2: All operations are performed at the same time.
Note 3: A PWB is not ejected from the OUT station.
Note 4: A PWB is not loaded onto the OUT station.
8 35
The following four kinds of station status are assumed when the machine transports a
board from left to right.
1. There is no board on both the IN station and
OUT station.
2. A board is loaded onto the IN station.
3. A board is loaded onto the OUT station. 4. Boards are loaded onto both the IN station
and OUT station.
A board is ejected in the following three ways when the machine transports a board from
left to right.
I. A board is ejected from the IN station. II. A board is ejected from the OUT station.
III. Boards are ejected from both the IN station
and OUT station.
A board is transported between two stations as shown below (from left to right):
A board is transported from the IN station to the
OUT station.
A board is sent into the machine in the following three ways when the machine
transports it from left to right:
A. A board is loaded onto the IN station. B. A board is loaded onto the OUT station.
C. Boards are loaded onto both the IN station
and OUT station.
IN station OUT station IN station OUT station
IN station OUT station IN station OUT station
IN station OUT station IN station OUT station
IN station OUT station
IN station OUT station
IN station OUT station IN station OUT station
IN station OUT station
8 36
8.3.3 Automatic PWB width adjustment control
When you select the [Conveyor] command on the [Ctrl] menu, then the [Auto width
conveyor control], the following “AWC control” dialog box appears on the screen.
Figure 8.3.3 “AWC control” dialog box
(1) Control item
Select a control item with the corresponding radio button.
(2) Control button
With the control button, execute the control item you selected.
1) Origin
This item returns the automatic PWB width adjustment unit to its home
position.
When the control item “Origin” is checked, click the <EXEC> button or
press the F3 key.
2) Change width
This item changes the PWB transport width.
When the control item “Change width” is checked, click the <EXEC> button
or press the F3 key.
(3) State display
The state of each sensor and each unit is always displayed on the screen.