8 − 37 8.3.4 Movable station control (Supported by a KE-2030) W hen y ou select t he [Conveyor] command on the [ Ctrl] m enu, then the [ Movable station contr ol] comm and, the f ollowing “Movable station control” dialog…

100%1 / 1361
8 36
8.3.3 Automatic PWB width adjustment control
When you select the [Conveyor] command on the [Ctrl] menu, then the [Auto width
conveyor control], the following “AWC control” dialog box appears on the screen.
Figure 8.3.3 “AWC control” dialog box
(1) Control item
Select a control item with the corresponding radio button.
(2) Control button
With the control button, execute the control item you selected.
1) Origin
This item returns the automatic PWB width adjustment unit to its home
position.
When the control item “Origin” is checked, click the <EXEC> button or
press the F3 key.
2) Change width
This item changes the PWB transport width.
When the control item “Change width” is checked, click the <EXEC> button
or press the F3 key.
(3) State display
The state of each sensor and each unit is always displayed on the screen.
8 37
8.3.4 Movable station control (Supported by a KE-2030)
When you select the [Conveyor] command on the [Ctrl] menu, then the [Movable
station control] command, the following “Movable station control” dialog box appears
on the screen.
Figure 8.3.4 “Movable station control” dialog box
(1) Control item
Select a control item with the corresponding radio button.
(2) Control button
With the control button, execute the control item you selected.
The control buttons displayed vary depending on the control item you selected.
1) PWB detect pin
This item turns on and/or off the PWB detecting cylinder valve.
When the control item “PWB detect pin” is checked, click the <ON>, <ON>
or <ON/OFF> button, or press the F3, F4 or F5 key.
The state display is updated when the cylinder is controlled completely.
8 38
2) Origin
This item returns the movable station to its home position.
When the control item “Origin” is checked, click the <EXEC> button or
press the F3 key.
3) Moving
This item moves the movable station.
When the control item “Moving” is checked, click the <EXEC> button or
press the F3 key.
(3) State display
Each unit state is displayed when the unit is controlled completely.