KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第656页
9 − 2 9.2 Warmi ng up 9.2.1 Warm-up initial screen W hen y ou select t he [W arming Up] com mand on the [Maintenance] m enu invoked fr om the menu bar of t he main menu, the f ollowing W arm-up initial screen appears. Fi…

9 − 1
CHAPTER 9 MAINTENANCE MODE
9.1 Overview
The setting items provided on the Maintenance menu are shown in Table below.
No. Maintenance command Description
1 Warming up Sets the time or number of times.
2 Idle Conveyor Sets when to use the machine as a PWB transportation buffer.
3
Machine Management
information
Displays the entire machine operation information.
4 Self-Calibration See Chapter 10 "SELF CALIBRATION".
− After selecting the[Maintenance] command on the menu bar displayed on the
Main screen, invoke each screen.

9 − 2
9.2 Warming up
9.2.1 Warm-up initial screen
When you select the [Warming Up] command on the [Maintenance] menu invoked
from the menu bar of the main menu, the following Warm-up initial screen appears.
Figure 9.2.1 Warm-up dialog box
- When you press the <START> switch, the warm-up operation starts.
9.2.2 Setting the conditions for warming-up operation
When you click the <SET> button, the following "Setting" dialog box appears on the
screen.
Figure 9.2.2.1 Setting dialog box
(1) Device to be warmed up
- Select the device to be warmed up: Axis, Conveyor and/or MTC.
- If the MTC is not checked on the "Device enable" menu invoked from the
Machine Setup menu, the item "MTC" is disabled, and you cannot select it.
- Any of these devices is not selected, the <OK> button is disabled.
− Initial setting: Axis

9 − 3
(2) Setting the pause time and number of times
- Set the time spent for stopping warming-up operation and the number of times
you are to perform warming-up operations.
- The available values vary depending on the warming-up operation terminating
conditions.
- Time: 0 to 9999 (minutes)
Note: When "0" is set, warming-up operation will not finish until you suspend it.
- Number: 1 to 999999
− Initial value: 0
(3) Setting the condition for terminating warming-up operation
- Select the condition for terminating warming-up operation: Time or Number.
− Initial setting: Time
(4) Setting the speed
- Set the speed of an axis.
- You can select high speed (High) or middle speed (Middle).
− Initial setting: Middle
Note: The axis speed is fixed to “Middle” for the standard specifications
(see Figure 10.2.2.1.)
Contact us or your dealer for the details on the speed setting (variable).