KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第698页

10 − 14 10.6 VCS Offset (Not A vailable wi th a KE-2010) W hen y ou select t he [Set-up g roup] com mand on the menu bar , then t he [VCS off set] command on the displayed menu, the f ollowing “VCS camera off set” dialog…

100%1 / 1361
10 13
Set the vacuum of the calibration block to ON to pick the jig.
Using the OCC, check the position of the jig, and measure the center
position and the inclination of the jig.
An error occurs if two holes of the jig cannot be recognized. In this case,
remount the jig.
Pick the jig with the selected head, then set the vacuum of the calibration
block to OFF.
Recognize the jig with the laser alignment unit.
Calculate the laser alignment unit mounting angle and the head mounting
position based from the inclination of the jig obtained at Step 4 and the
recognition results at Step 6.
Using the OCC, recognize the calibration block position to calculate its
center position and inclination.
Mount the jig at the center of the calibration block, then set the vacuum of
the calibration block to ON to pick the jig.
To mount the jig, the machine corrects the inclination of the jig calculated
at Step 4, the laser alignment unit mounting angle and the head mounting
position calculated at Step 7, and the inclination of the calibration block
calculated at Step 8.
Using the OCC, recognize the position of the jig.
An error occurs if the distance from the jig to the calibration block is 1 mm
or longer (absolute value). In this case, you may have to set the MS
parameters again.
Repeat steps 4 to 10.
(When the left 1 head is selected)
The machine has finished measurement operation.
To repeat the measurement operation, select the <Exec.> button.
When you select the <Exec.> button, the previous screen reappears.
To measure another head, select the desired head in the “Select Head”
combo box.
When you change the selected head in the “Select Head” combo box, the
initial screen appears.
To quit Self-calibration mode, click the <OK> button.
10 14
10.6 VCS Offset (Not Available with a KE-2010)
When you select the [Set-up group] command on the menu bar, then the [VCS offset]
command on the displayed menu, the following “VCS camera offset” dialog box
appears on the screen.
Figure 10.6.1 “VCS camera offset” dialog box
VCS setting
Select the VCS to be set in the “Select VCS” combo box.
You cannot select any unit which is not checked (that is, “not used”) on the “Device
enable” menu invoked from the Machine Setup menu.
When you press the Alt key and the down arrow key at the same time, the
following list appears on the screen.
(1) Setting items
No. Item Description
1 Assembling position of VCS Each VCS assembling position
(Assembling position
already set)
(Assembling position
measured)
10 15
(2) How to set
Follow the instructions displayed on the dialog box above to set the VCS
selected in the “Select VCS” combo box.
When you click the <OK> button, your settings become valid (but not be
saved at this point).
When you click the <CANCEL> button, your settings become invalid.
How to operate
Follow the instructions displayed on the screen. The appropriate value is
automatically obtained.
(When the right standard VCS is selected)
The machine sets up the VCS selected in the “Select VCS” combo box.
Select the <Exec.> button.
When you select the <Exec.> button, the machine moves the selected head
along the theta axis in from 0 to 15-degree units 24 times repeatedly to obtain
the average value.
Measurement operation
Attach the No. 508 nozzle onto the FMLA head.
An error occurs if the nozzle is set for the ATC. In this case, assign the
nozzle on the “ATC nozzle setup” menu invoked from the Machine Setup
menu.
The FMLA head picks up the jig from the jig station.
Move the FMLA head to the position where the selected VCS camera
recognizes.
The machine recognizes the jig position with the VCS to measure the
center position of the jig.