11 − 20 ④ Non-stop oper ation − Using this check box, set whether to perf orm the Non-stop oper ation or not. − W hen you check t he check box of this option, the non-stop oper ation funct ion is enabled. − W hen f eeder…

100%1 / 1361
11 19
11.4.7 Setting the Function enable option
When you select the [Options] command on the menu bar, then [Option Setting]
command, the Operation option setting dialog box appears on the screen.
When you select the <Function enable> tag, the Use Unit option setting screen
appears as shown in Figure 11.4.7.
Figure 11.4.7 Function enable option setting screen
(Display example: KE-2020 screen)
(1) How to set the item
Tombstone detection
Using the check box, set whether to detect a tombstone error.
When you check the check box of this option, the "Tombstone det." setting
of Component data becomes effective.
Component dimension check
Using the check box, set whether to check a component whose size is
different from the regular ones.
When you check the check box of this option, the "Acceptable width
(length, and height)" setting of Component data becomes effective.
Component orientation check
Using this check box, set whether to check a component posture.
When you check this check box, the system compares the ratio of the
shorter side to the longer side specified in Component data and the ratio
measured. If the difference between the ratio in Component data and the
measured ratio is not within a certain range, it is regarded as a component
posture error.
11 20
Non-stop operation
Using this check box, set whether to perform the Non-stop operation or
not.
When you check the check box of this option, the non-stop operation
function is enabled.
When feeders are assigned to the front and rear sides symmetrically with
the Program Editing utility, the non-stop operation gets executable.
When you check the check box of this option, the system performs the
non-stop operation.
Alternate
When you enable the “Non-stop operation” function, this check box is
enabled. When enabled, check this check box to execute the alternate
production mode function in Non-stop operation mode.
When you check this check box, Alternate Production mode is enabled.
The status of this check box, checked or not checked, is not affected by
the setting of the “Non-stop operation”, enabled or disabled.
Non-stop operation (MTC) (Not available for a KE-2030)
Using this check box, set whether to perform the Non-stop operation
(MTC) or not.
When you check the check box of this option, the non-stop operation
function is enabled.
This item is enabled only if “TR6D” is selected as an MTC on the “Device
enable” menu invoked form the Machine Setup menu.
Alternate (MTC) [Not available for a KE-2030]
When you enable the “Non-stop operation [MTC]” function, this check box
is enabled. When enabled, check this check box to execute the alternate
production mode function in MTC Non-stop operation mode.
When you check this check box, MTC Alternate Production mode is
enabled.
The status of this check box, checked or not checked, is not affected by
the setting of the “Non-stop operation [MTC]”, enabled or disabled.
Non-stop operation (MTS) (Not available for a KE-2030)
Using this check box, set whether to perform the Non-stop operation (MTS)
or not.
When you check the check box of this option, the non-stop operation
function is enabled.
This item is enabled only if “TR5D” is selected as an MTS on the “Device
enable” menu invoked form the Machine Setup menu.
11 21
Alternate (MTS) [Not available for a KE-2030]
When you enable the “Non-stop operation [MTS]” function, this check box
is enabled. When enabled, check this check box to execute the alternate
production mode function in MTS Non-stop operation mode.
When you check this check box, MTS Alternate Production mode is
enabled.
The status of this check box, checked or not checked, is not affected by
the setting of the “Non-stop operation [MTS]”, enabled or disabled.
Non-stop operation (DTS) (Not available for a KE-2030)
Using this check box, set whether to perform the Non-stop operation (DTS)
or not.
When you check the check box of this option, the non-stop operation
function is enabled.
Automatically setting the number of DTS components when replenished
If you press the <SUPPLY> switch to replenish components, then press
the <SUPPLY> switch again to release Component Supplying mode while
the system is producing a PWB in Non-stop mode, this function
automatically sets the number of components that are located on the level
you replenished so that it can indicate the level is fully replenished.
This item is enabled only if “DTS” is enabled on the “Device enable” menu
invoked form the Machine Setup menu.
Enable Auto Compo. presence check of MTC (Not available for a KE-2030)
Using the combo box, select the check operation of MTC components
when picked up (“a.” is selected as the default).
a. Do not check: the system does not check any component.
b. Read file the system checks components when a production
program file is changed.
c. Supply component: the system checks components when components
finish being replenished by your pressing the
Supply key of an MTC.
When you select “Read file” or “Supply component”, the system checks to
see if there is any component on a tray with the HMS located inside an
MTC when it picks up a component from a tray of the MTC that is
replenished fully. Then, the system starts picking up a component from
where a component is actually located.
When you select “Do not check”, the system always starts picking up
components from the first component of a tray when the tray is replenished
fully.
This item is enabled only if “TR6D” is selected as an MTC on the “Device
When you validate the selected item(s), click the <OK> button. If you do not want to