KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第759页

13 − 3 13.2 Check 13.2.1 A ir pressure Checking t o see if the air pressur e is 0.49 Mpa. How to adjust the ai r pressure 1) Set the control t o the Open posit ion as shown in Figure below. CLOSE OPEN 2) Pull t he knob o…

100%1 / 1361
13 2
Notes: 1. Lubrication is to be performed using the supplied oil. Besides the supplied
grease (EP2), SHELL Albania Grease 1 can be used for the parts to be
greased only.
2. Never apply any grease other than grease (CGrease) to the parts to be
lubricated with "Grease (CGrease)". For other parts, do not use any
grease not specified by JUKI.
3. Machine oil (No. 1): Class four, third petroleum
Grease (EP2): Not dangerous product regulated with the Fire-Defense law
Grease (CGrease): Not dangerous product regulated with the Fire-Defense
law.
13 3
13.2 Check
13.2.1 Air pressure
Checking to see if the air pressure is 0.49 Mpa.
How to adjust the air pressure
1) Set the control to the Open position as shown in Figure below.
CLOSE OPEN
2) Pull the knob of the regulator downward, then rotate it so that the pressure of
the used air can become 0.49 MPa.
3) Peep into the small window located at the center of the pressure switch to
check to see if the pressure is 0.39 MPa (this value is set at the factory).
4) If there is any oil or water in the drain, push the control to drain it out.
WARNING
To prevent the body from injury which can be caused by accidental
activation of the machine, turn off the power of the machine before
following the operation above.
Drains
13 4
13.2.2 Piping and joint
Check that there is no air leakage.
WARNING
To prevent the body from injury which can be caused by accidental
activation of the machine, turn off the power of the machine before
following the operation above.
13.2.3 Unit air cylinder
Turn on the power of the machine, select the machine setup items, and check that
operation is possible.
Check to see if there is no air leakage.
Front side.
Finger valve