KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第860页

55 E249010 “Servo is in the f ree state. The bank mark recognition is aborted” [Cause] T he axis could not m ove since the s ervo was not lock ed. [Treatm ent] Please lock the ser vo using S-FREE s witch. Q249051 “Feeder…

100%1 / 1361
54
E249001 “The origin point return is non-completion. Please operate again
after completing the origin point return”
[Cause] The axis has not yet been returned to home.
[Treatment] Please perform the Return to home with ORIGIN switch.
E249002 “The OCC device is unused. The bank mark recognition is aborted”
[Cause] OCC or OCC2 was set not to “Use” in the Use unit in Setup when performing the
Bank mark recognition.
[Treatment] Please set OCC or OCC2 to “Use” in the Use unit in Setup.
E249003 “The stop key was pressed. The bank mark recognition is aborted”
[Cause] The stop key was pressed while the Bank mark recognition was in operation.
[Treatment] “OK” button will completely abort the Bank mark recognition process.
E249004 “The axis cannot be moved to recognition position. The bank mark
recognition is aborted”
[Cause] An error occurred in the axis traveling.
[Treatment]
E249005 “The bank mark recognition error. The bank mark recognition is
aborted”
[Cause] An error occurred in the Mark recognition by OCC unit.
[Treatment] Please check and see if feederbank is dirty or if something is concealing the
feederbank.
If the mark does not fit in the frame, you need to adjust the mark.
E249006 “MTS power off”
[Cause] The power supply of MTS is off.
[Treatment] Please turn on the power supply of MTS.
E249007 “MTS cannot move because of cover opening”
[Cause] The cover of the machine is open.
[Treatment] Please close the cover.
E249008 “The door of MTS opens”.
[Cause] Failed to draw the MTS tray out since the MTS door was open.
[Treatment] Please close the MTS door.
E249009 “MTS offline”
[Cause] MTS is not online.
[Treatment] Please make MTS online.
55
E249010 “Servo is in the free state. The bank mark recognition is aborted”
[Cause] The axis could not move since the servo was not locked.
[Treatment] Please lock the servo using S-FREE switch.
Q249051 “Feeder bank has descended. Do you want to lift the feeder bank up
and continue the bank mark recognition?
[Cause] The feeder bank had been descended when you tried to perform the Bank mark
recognition.
[Treatment] YES” button will continue the Bank mark recognition process.
NO” button will completely abort the Bank mark recognition process.
I249070 “Set online for MTS”
[Cause] Failed to draw the MTS tray out since the MTS was not online.
[Treatment] Please make MTS online.
I249071 “Please close the door of MTS”
[Cause] Failed to draw the MTS tray out since the MTS door was open.
[Treatment] Please close the MTS door.
56
E290000 “The origin point return is non-completion. Please execute the
teaching after the origin point returns”
[Cause] Home returning has not been complete yet.
[Treatment] Please press ORIGIN button to perform the Home returning, then try the teaching
again.
E290001 “The OCC device is set in unused by the setup. The teaching in the
OCC device cannot be done”
[Cause] OCC device is set to “not use” in the Use unit in Setup.
[Treatment] If OCC is available, please set it to “use” in the Use unit in Setup. If not, this
procedure cannot be executed.
E290002 “The bad mark reader device is set in unused by the setup. The
teaching in the bad mark reader device cannot be done”
[Cause] The Bad mark reader device is set to “not use” in the Use unit in Setup.
[Treatment] If the Bad mark reader device is available, please set it to “use” in the Use unit in
Setup. If not, this procedure cannot be executed.
E290003 “The HMS device is set in unused by the setup. The teaching in the
HMS device cannot be done”
[Cause] The HMS device is set to “not use” in the Use unit in Setup.
[Treatment] If the HMS device is available, please set it to “use” in the Use unit in Setup. If not,
this procedure cannot be executed.
E290004 “The pick up point in the right feeder bank cannot be the teaching
with a left device. Please use a right device”
[Cause] This error occurs when trying to teach a feeder pickup coordinate on the right
feeder bank to the machine by using a device on the left side.
[Treatment] Please use a device on the right side when teaching a feeder pickup coordinate
on the right feeder bank to the machine.
E290005 “The pick up point in the left feeder bank cannot be the teaching
with a right device. Please use a left device”
[Cause] This error occurs when trying to teach a feeder pickup coordinate on the left
feeder bank to the machine by using a device on the right side.
[Treatment] Please use a device on the left side when teaching a feeder pickup coordinate on
the left feeder bank to the machine.
E290006 “The memory access error occurred”
[Cause] Failed to write the data in or to read the data from the shared memory.
[Treatment] Please reboot the machine. If the error occurs even after rebooting, please
contact our technical service dept. for information.