KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第862页

57 E290007 “The Head device is set in unused by the setup” [cause] The s pecif ied head is set to “not us e” in the Use unit in Setup. [Treatm ent] If the spec ified head is available, pleas e set it to “us e” in the Use…

100%1 / 1361
56
E290000 “The origin point return is non-completion. Please execute the
teaching after the origin point returns”
[Cause] Home returning has not been complete yet.
[Treatment] Please press ORIGIN button to perform the Home returning, then try the teaching
again.
E290001 “The OCC device is set in unused by the setup. The teaching in the
OCC device cannot be done”
[Cause] OCC device is set to “not use” in the Use unit in Setup.
[Treatment] If OCC is available, please set it to “use” in the Use unit in Setup. If not, this
procedure cannot be executed.
E290002 “The bad mark reader device is set in unused by the setup. The
teaching in the bad mark reader device cannot be done”
[Cause] The Bad mark reader device is set to “not use” in the Use unit in Setup.
[Treatment] If the Bad mark reader device is available, please set it to “use” in the Use unit in
Setup. If not, this procedure cannot be executed.
E290003 “The HMS device is set in unused by the setup. The teaching in the
HMS device cannot be done”
[Cause] The HMS device is set to “not use” in the Use unit in Setup.
[Treatment] If the HMS device is available, please set it to “use” in the Use unit in Setup. If not,
this procedure cannot be executed.
E290004 “The pick up point in the right feeder bank cannot be the teaching
with a left device. Please use a right device”
[Cause] This error occurs when trying to teach a feeder pickup coordinate on the right
feeder bank to the machine by using a device on the left side.
[Treatment] Please use a device on the right side when teaching a feeder pickup coordinate
on the right feeder bank to the machine.
E290005 “The pick up point in the left feeder bank cannot be the teaching
with a right device. Please use a left device”
[Cause] This error occurs when trying to teach a feeder pickup coordinate on the left
feeder bank to the machine by using a device on the right side.
[Treatment] Please use a device on the left side when teaching a feeder pickup coordinate on
the left feeder bank to the machine.
E290006 “The memory access error occurred”
[Cause] Failed to write the data in or to read the data from the shared memory.
[Treatment] Please reboot the machine. If the error occurs even after rebooting, please
contact our technical service dept. for information.
57
E290007 “The Head device is set in unused by the setup”
[cause] The specified head is set to “not use” in the Use unit in Setup.
[Treatment] If the specified head is available, please set it to “use” in the Use unit in Setup. If
not, this procedure cannot be executed.
E290008 “HW error. Execution is aborted”
[Cause] A requested action to an axis or other hardware got an error. There may be a
possibility of alarm occurrence, servo free, Emergency STOP, etc.
[Treatment] Please try Servo Free unlocking, Home returning, etc.
Q290500 “It is not possible to move to specified position with this device.
Please push ‘No’ when you discontinue ‘Yes’ when the teaching is
started from the current position”
[Cause] You can not move to the previously set coordinates with the device selected by
HOD. You are asked if to resume the teaching from the current position.
[Treatment] If you want to continue the process, press “Yes”. If not, press “No”.
Q290501 “The teaching operation is executed. Please confirm safety. Please
push ‘No’ when you discontinue ‘Yes’ when executing this”
[Cause] You are asked if to perform the safety check since this operation takes axis
traveling.
[Treatment] If you want to continue the process, press ‘Yes’. If not, press ‘No’.
Q290502 “The position cannot be corrected. Please push ‘No’ when you
discontinue ‘Yes’ when correction is not considered and teaching is
executed”
[Cause] You need to correct the coordinates in order to teach the coordinates to the
machine accurately, but the Mark recognition that is necessary for the coordinate
correction failed for some reason. You are asked if to continue the teaching
although the accurate teaching cannot be expected if you continue the process..
[Treatment] If you want to continue the process, press ‘Yes’. If not, press ‘No’.
Q290503 “The mark has already been registered. Do you overwrite?”
[Cause] There is a mark data left, which was registered before. You are asked if to
overwrite the data.
[Treatment] If you want to overwrite the data, press ‘Yes’. If not, press ‘No’.
58
E291000 “Conveyor already operated, it is not possible to operation”
[Cause] The conveyor has already been in operation.
[Treatment] Please wait for a while and try again.
E291001 “The origin point return is non-completion. Please operate again
after completing the origin point return”
[Cause] Home returning has not been complete yet.
[Treatment] Please press the ORIGIN button to perform the Home returning, and try again.
E291002 “The axis cannot be moved to escape point. Execution is aborted”
[Cause] Failed to move the axis to the escape point.
[Treatment] Please check and see if the axis works properly with Manual control.
E291003 “The conveyor cannot be moved. Execution is aborted”
[Cause] The conveyor did not work for some reason.
[Treatment] Please check and see if the conveyor works properly with Manual control.
E291004 “The conveyor became a time-out. Execution is aborted”
[Cause] PWB conveying had a time-out error.
[Treatment] Please check and see if the conveyor works properly with Manual control.
E291005 “The axis cannot be moved. Execution is aborted”
[Cause] The axis could not move for some reason.
[Treatment] Please check and see if the axis works properly with Manual control.
E291006 “The BOC mark data is not set. Operation is aborted”
[Cause] BOC mark was not set in the Board data or the Board data is incomplete.
[Treatment] Please set and complete the board data.
E291007 “The OCC device is set in unused by the setup”
[Cause] The OCC device is set to “not use” in Setup.
[Treatment] If the device is available, set it to “use” in Setup. If not, this operation cannot be
executed.
E291008 “Value is mistake”
[Cause] The value is wrong when you hit the Enter key to define it.
[Treatment] Please check the entered value.
E291009 “Value out of range”
[Cause] The value when you hit the Enter key to define it exceeded the input range.
[Treatment] Please enter a value which is within the input range.
E291010 “Conveyor margin out of range. It is not possible to operation”
[Cause] Failed to take the value in as a margin since there is a too much difference