E292000 “No registered data”
[Cause] The following procedures were taken place when the number of the registered
issue of Mark Database is zero.
1. Press [Rename(C)] button or [Delete(D)] button on the Mark Database
Management screen.
2. Press [Replace(A)] button on the Registration Mark Database screen.
3. Press [Copy(C)] button on the Vision Copy screen.
[Treatment] The procedures above can not be performed when there is no registry in the
Mark Database.
E292001 “Please select the mark”
[Cause] 1. Although [Rename (C)] button or [Delete(D)] button screen were pressed on
the Mark Database Management screen, there is no selected mark to be an
object of the action.
2. Although [Copy(C)] button was pressed on the Vision Copy screen, there is no
selected mark to be an object of the action.
[Treatment] Please select a mark to be an object of each action.
E292002 “Registration number was exceeded”
[Cause] As the maximum number of registration is 100, you can not register any new data
in the Mark Database.
[Treatment] Please delete unnecessary marks on the Mark Database Management screen.
E292003 “The mark of the same registration name exists”
[Cause] 1. On the Mark Data name change screen which is shown when pressing
[Rename(C)] button on the Mark Database Management screen, a name
which was entered as “a name after the change” has already been registered
in the Mark Database.
2. When pressing [Add New(N)] button or [Replace(A)] button on the
Registration Mark Database screen, a name which was entered as “a name to
register” has already been registered in the Mark Database.
[Treatment] Please enter the names that have not been registered in the Mark Database yet.
E292004 “Please input the registration name”
[Cause] 1. Although [OK] button was pressed on the Mark Data name change screen that
is shown when pressing [Rename(C )] button on the Mark Database
Management screen, “a name after the change” has not been entered yet.
2. Although [Add new(N)] button or [Replace(A)] button was pressed on the Mark
Database register screen, “a name to register” has not been entered yet.
[Treatment] Please enter a mark name.
E292005 “Please select the registered area”
[Cause] Although [Replace(A)] button was pressed on the Mark Database Registration
screen, there is no selected mark to be an object of the action.
[Treatment] Please select a mark to be an object of overwriting.
Q292501 “The selected mark data is deleted. Is it good?”
[Cause] This message appears in order to confirm you if to delete the data when
pressing[Delete(D)] button on the Mark Database Management screen.
[Treatment] If you want to delete the mark, press [OK] button. If not, press [Cancel] button.
E301000 “Memory allocation error”
[Cause] The working space can not be saved.
63
[Treatment] Please add some more memory available to save the working space.
E301001 “There is no input character”
[Cause] There was no character when you hit Enter key to define characters.
[Treatment] Please enter characters.
E301002 “Input character has irregularities”
[Cause] The letter strings had irregularities when defining the input.
[Treatment] Please enter proper characters.
E301003 “Input value exceeds predetermined data range. (Data range:%s)”
[Cause] The value when defining the input exceeded the input range.
[Treatment] Please enter the values that are within the range.
E301012 “An error occurred while measuring nozzle height by Laser”
[Cause] An error occurred during the laser height measurement by laser.
[Treatment] Something might be wrong with Laser alignment. Please check it.
E301015 “Specify user’s individual nozzle No.”
[Cause] When measuring the width of a nozzle’s outer shape by laser, the output does not
coincide with that of a standard nozzle. Therefore, the nozzle number can not be
set automatically. As a temporary nozzle No., the smallest nozzle number (530)
of option nozzles is set for the nozzle.
[Treatment] If the nozzle is a standard nozzle, please measure it again. If the same result
comes out, something might be wrong with the nozzle shape. Please check the
nozzle. If the nozzle is an option nozzle, the nozzle number set is just a temporary
number and might be wrong. Please set a nozzle number for the nozzle again. If
you measure the nozzle again after set a nozzle number for the nozzle, the
temporary nozzle number will be set again.
E301016 “An error occurred while taking nozzles off”
[Cause] This message occurs when the machine determines that the nozzle is still on the
head even despite the nozzle removal took place.
[Treatment] If the nozzle is not on the head, the laser might be too dirty to work properly.
Please clean the laser. Also, please check and see if the slide plate can slide
properly or the sensor works properly with Manual control. If the slide plate or the
sensor does not work well, something might be broken. Please take a note of the
error No. and contact our technical service dept. for information.
E301017 “Selected device can not move to this position. Please reselect
other device on HOD”
[Cause] You cannot go into the teaching mode since you can not move to the speicified
position with the device selected by HOD.
[Treatment] Please reselect a device available.
64
E301018 “Selected device is not installed. Please reselect other device on
HOD”
[Cause] Since the device selected by HOD has not been installed (the installation of the
device is not set in the option of MS parameter), you can go into the teaching
mode.
[Treatment] Please reselected a device available.
E301019 “Return to home has not yet been completed”"
[Cause] The axis has not yet returned to home.
[Treatment] Please perform the Return to home with ORIGIN switch.
E301020 “MTC power off”
[Cause] Failed to draw MTC shuttle out when teaching MTC shuttle pick position to the
machine sinceMTS was not ON.
[Treatment] Please turn on the power supply of MTC.
E301021 “MTC offline”
[Cause] Failed to draw the MTC shuttle out when teaching MTC shuttle pick position to
the machine since MTC was not online.
[Treatment] Please make MTC online.
E301023 “There is no installed head”
[Cause] There is no head available.
[Treatment] Please set any necessary heads to “use” in the Use unit in Machine Setup.
E301024 “Selected device is disable. Please reselect other device on HOD”
[Cause] Since the device selected by HOD is non-use device (it is set to “not use” in the
Use unit in Machine Setup), you can not go into the teaching mode.
[Treatment] Please select a device available.
E301025 “MTC is disable”
[Cause] MTC can not be controlled since it is non-use device (it is set to “not use” in the
Use unit in Machine Setup)
[Treatment] Please set the MTC to “use” in the Use unit in Machine Setup.
E301026 “Servo is in the free state”
[Cause] The axis could not move since the servo is not locked.
[Treatment] Please lock the servo with S-FREE switch.
W301027 “Teached data is invaled”
[Cause] When an error caused by ‘out of the measurement range’ occurred while learning
the Z axis coordinate by HMS (when “---“ is shown for Z in the teaching dialog),
you can not learn the coordinate even if you hit the enter key on HOD. The
coordinate also can not be learned when other error occur while teaching.
[Treatment] When you learn the coordinate of Z axis by HMS, please make sure that the
coordinate is within the measurement range.