KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第889页

84 E500303 “Det ected %s feeder float ” [Cause] A m atter that may interrupt the Feeder f loatation sensor oc curr ed. ? : where the matter oc curred. On the front s ide On the rear s ide On both sides [Treatm ent] Pleas…

100%1 / 1361
83
E500213 “The program can not be produced in the <%s> Production mode”
[cause] The production can not be performed with the specified production mode.
? : Production mode
Input order
Optimization order
[Treatment] In the Production dialog, please select a production mode that is NOT currently
selected.
E500214 “Reference error from the Pick data to the Component data”
[Cause] The error appears when the Pick data and Component data are broken.
[Treatment] This is a program error. Please make a note of the cause of the error and the
error code, then contact our technical service Dept. for information.
E500215 “In the accumulative mode, the number of PWBs to be produced is
the same as that of produced PWBs. Production can not be
executed”
[Cause] [accumulate the number of produced PWBs] is checked in the Operation option,
and the number of produced PWBs in the Production dialog already exceeded
the number of PWBs to be produced. Therefore, the production can not be
started.
[Treatment] Please re-set a number of PWBs to be produced that is bigger than the number
of produced PWBs, or disable [accumulate the number of produced PWBs] in the
Operation option.
E500220 “Device enable of setup does not match pick data”
[Cause] There is a Component or Pick data that is from a feeder which is not set ‘to use’
in the Setup.
[Treatment] Please go to the Production Program Editor and see the Component and Pick
data.
E500300 “Origin retrieval has not yet been completed”
[Cause] You tried to resume the production without completing the Origin retrieval after an
unexpected stop such as Emergency stop.
[Treatment] Please perform the Origin retrieval by pressing the ORIGIN button on the
operation panel.
E500301 “Servo is turned OFF”
[Cause] The production can not be executed since the Servo is free.
[Treatment] Please perform the Origin retrieval by pressing the ORIGIN button on the
operation panel.
E500302 “Air was down”
[Cause] The air pressure is getting down.
[Treatment] Please adjust the air pressure to its original level.
84
E500303 “Detected %s feeder float
[Cause] A matter that may interrupt the Feeder floatation sensor occurred.
? : where the matter occurred.
On the front side
On the rear side
On both sides
[Treatment] Please remove the obstruction that may be interrupting the sensor.
E500401 “Input order Simple Opt. Error <%s>”
[Cause] An error occurred while optimizing the pick positions by input orders.
? : the details of the error
There is no component corresponding to the feeder.
The head can not travel to the feeder/MTC position.
The head can not travel to the holder/MTS position.
There is no head available to place the component.
There is no head that meets the centering type.
An internal error of the Input order Simple Opt. Error process.
Treatment] 1 and 6 are a program error. Please make a note of the cause of the error and
the error code, then contact our technical service Dept. for information.
In case of 2, 3, and 4, please go to the Production Program Editor and see the
specified head(s) in the Placement data.
In case of 5, please go to the Production Program Editor and see the centering
type in the Component data.
E500500 “Teaching can not be executed”
[Cause] You are trying to teach unexecutable data to the machine.
Unexecutable data:
Data except ref. circuit in the Placement position teaching.
Components except tray component in the Pick position teaching.
When multiple heads are working at the same time.
[Treatment] You can not perform a teaching with the current status. Please go on the process.
E500501 “The selected device can not be used”
[Cause] You selected a device not available.
[Treatment] Please change devices to use.
E500502 “With the selected device, it is impossible to move to the aimed
position”
[Cause] You can not move to the specified position with the selected device.
[Treatment] Please select another device.
E500503 “Standard Pin position illegal. Correct coordinates can not acquire”
[Cause] The position of the reference pin is not correct.
[Treatment] In the Setup, please teach the positions of the reference pin and follower pin to
the machine.
85
E500605 “An error occurred when disposing a component
[Cause] This error occurs if the component present check at a component disposal action
gets an error when starting a production.
[Treatment] Pressing OK button will abort the process. In this case, the production will not be
executed.
E500700 “An error occurred while Auto. PWB Width Alignment Control. The
process gets discontinued”
[Cause] This error occurs if an error occurs or an action did not take place properly while
Auto. PWB Width Alignment Control.
[Treatment] Pressing OK button will abort the process. If a particular reason (Home returning
has not been complete, etc.) why Auto. PWB Width Alignment Control can not be
executed is given, please perform any means to get rid of the factor that stops
Auto. PWB Width Alignment Control. If any particular reasons are not given,
please, check the action of Auto. PWB Width Alignment Control by Manual
control .
E500701 “Para error. PWB Width Alignment Control occurred”
[Cause] This error occurred if an entered value to be defined by Enter key is wrong when
performing Auto. PWB Width Alignment Control.
[Treatment] Please check the entered value.
E500800 “A PWB is detected within the conveyors of both stations. Please
remove the PWB
[Cause] The production can not get started because PWBs are on the conveyors on both
sides when starting the production.
[Treatment] Please remove the PWBs from the conveyors by pressing OK button, and then
press START key again.
E500801 “A PWB is detected within the conveyor of the Left station. Please
remove the PWB
[Cause] The production can not get started because a PWB is on the conveyor on left
side when starting the production.
[Treatment] Please remove the PWBs from the conveyors by pressing OK button, and then
press START key again.
E500802 “A PWB is detected within the conveyor of the Right station. Please
remove the PWB
[Cause] The production can not get started because a PWB is on the conveyor on right
side when starting the production.
[Treatment] Please remove the PWBs from the conveyors by pressing OK button, and then
press START key again.