KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第899页

94 E506300 “I s the component supply reset?” [Cause] T his m es sage appears when ‘replenishm ent button’ on the Pause sc reen is pressed. [Treatm ent] Yes : Replenis hes com ponents. No : W ill not replenish com ponents…

100%1 / 1361
93
E506102 “Would you like to resume the production? The last suspended
position
%s
%s”
[Cause] This message appears if the production program is a resumable production when
starting a production.
(For 2030)
?? : Resumptive production starting position of each station.
[Treatment] Yes : Starts the production from the placement point which got illegal abortion
last time.
No : Will not resume the production but start a normal production that is set in
the Production Condition.
E506200 “You can resume the production from the last suspended position
[Circuit No. : %d Step No. : %d] Would you like to resume the
production?"
[Cause] This message appears if the production program is a resumable production when
starting a production.
(For 2030)
?? : Resumptive production starting position of each station.
[Treatment] Yes : Starts the production from the placement point which got illegal abortion
last time.
No : Will not resume the production but start a normal production that is set in
the Production Condition.
E506201 “You need to delete the file if you do not resume the production
from the last illegally suspended position. [Circuit No. : %d Step
No. : %d] Would you like to delete the file?”
[Cause] This message appears if the production program is a resumable production when
starting a production.
(Other than 2030)
?? : Resumptive production starting position of each station.
[Treatment] Yes : Starts the production from the placement point which got illegal abortion
last time.
No : Will not resume the production but start a normal production that is set in
the Production Condition.
E506202 “Would you like to resume the production? The last suspended
position [Circuit No. : %d Step No. : %d]”
[Cause] This message appears if the production program is a resumable production when
starting a production.
(Other than 2030)
?? : Resumptive production starting position of each station.
[Treatment] Yes : Starts the production from the placement point which got illegal abortion
last time.
No : Will not resume the production but start a normal production that is set in
the Production Condition.
94
E506300 “Is the component supply reset?”
[Cause] This message appears when ‘replenishment button’ on the Pause screen is
pressed.
[Treatment] Yes : Replenishes components.
No : Will not replenish components.
E506400 “The %s component is a protective component. Please remove the
component”
[Cause] This message appears before disposing the component if a protective component
is being picked by a head when starting a production.
? : head
[Treatment] OK button : Moves the head to the component disposal position.
E506401 “Cannot return component of %s. Trash component?”
[Cause] This message appears when starting a production if a component is being picked
by a head, the component is not a protective component, and the component
disposal is executed for the component that is un-returnable.
[Treatment] Yes : Disposes the component.
No : Resumes the production without disposing the component
E506500 “More than one component are selected. Would you like to try
execute Verification inspection for the first component listed?”
[Cause] This message appears if several components are selected to be verified when
executing the Verification inspection for the retry list.
[Treatment] Yes : Executes the Verification inspection for the first component listed.
No : Will not executes the Verification inspection.
E508001 “Pause as component protection. Take off component
[Cause] This message appears before disposing a protective component while a
production.
[Treatment] Please take the component off and press OK button.
E508100 “Set online for MTS”
[Cause] This message appears if MTS is not online when starting a production.
[Treatment] Please put MTS in online status and press OK button. Pressing Cancel button will
have you back to the status that is before pressing START key.
E508101 “Please close the door of MTS”
[Cause] This message appears if the MTS door is open when starting a production.
[Treatment] Please close the MTS door and press OK button. Pressing Cancel button will
have you back to the status that is before pressing START key.
E508200 “Remove the component from %s”
[Cause] This message appears when starting a production after a request of taking a
protective component off is issued and the head is moved to the component
disposal position.
[Treatment] Please take the component off the head and press OK button.
E508300 “The cause of the pause is not out of component. Measurement
95
cannot be performed”
[Cause] This message appears when a measurement functionality gets called by pressing
F5 key while pausing and the components are not running out.
[Treatment] Please press OK button.
E510001 “The error occurred by the XY axis”
[Cause] Something was wrong with XY axes movement.
[Treatment] Please perform the Home returning.
E510002 “The error occurred by the Z axis”
[Cause] Something was wrong with XY axes movement.
[Treatment] Please perform the Home returning.
E510003 “The error occurred by the Theta axis”
[Cause] Something was wrong with the Theta axis movement.
[Treatment] Please perform the Home returning.
E510004 “The error occurred by the axis”
[Cause] Something was wrong with axis movement.
[Treatment] Please perform the Home returning.
E510005 “The command error occurred”
[Cause] An un-recognizable command was issued.
[Treatment] A wrong version has been installed.
Please install the latest software.
E510006 “Failed in the opening of the master schedule”
[Cause] The software did not get started properly.
[Treatment] Please turn off the power supply of the machine and reboot it.
E510007 “Failed in create of the mail of the scheduler”
[Cause] The software did not get started properly.
[Treatment] Please turn off the power supply of the machine and reboot it.
E510008 “Failed in the opening of the mail of the application-manager”
[Cause] The software did not get started properly.
[Treatment] Please turn off the power supply of the machine and reboot it.
E510009 “Failed in the mail transmission to the application-manager”
[Cause] The software did not get started properly.
[Treatment] Please turn off the power supply of the machine and reboot it.
E510010 “Failed in the mail check”
[Cause] The software did not get started properly.