101 E512832 “L4 HEAD : Cannot use t he specifi ed feeder for the pi ck position. ” [Cause] T he pick X coordinate of the L4 head in production is considerably differ ent from the specif ied coordinate in pic k data. [Tre…

100%1 / 1361
100
E512821 “L3 HEAD: Recognized angle is wrong.”
[Cause] Component measurement and recognition with the L3 head output incorrect
angles during production.
[Treatment] (1) Check if the outline dimensions and pick angle are correctly specified in
component data and pick data.
(2) Exit every application and shut down the operating system. Then turn off
machine power and turn it on again.
If the error persists after the restart, there is the possibility of measurement unit
failure, recognition unit failure and/or improper operation sequence. Stop using
the machine, take a note of the error number, and contact our service engineer or
the agency.
E512822 “L3 HEAD: Cannot use the specified feeder for the pick position.
[Cause] The pick X coordinate of the L3 head in production is considerably different from
the specified coordinate in pick data.
[Treatment] Exit every application and shut down the operating system. Then turn off machine
power and turn it on again.
If the error persists after the restart, there is the possibility of CPU failure,
memory failure and/or improper operation sequence. Stop using the machine,
take a note of the error number, and contact our service engineer or the agency.
E512823 “L3 HEAD: An encoder counter overflow was detected while the
theta-axis was moving.”
[Cause] The encoder counter for the L3 theta-axis overflows during production.
[Treatment] Exit every application and shut down the operating system. Then turn off machine
power and turn it on again.
If the error persists after the restart, there is the possibility of CPU failure,
memory failure and/or improper operation sequence. Stop using the machine,
take a note of the error number, and contact our service engineer or the agency.
E512824 “L3 HEAD: A position deviation was detected while the theta-axis
was moving.”
[Cause] The encoder counter for the L3 theta-axis is considerably different from the angle
specified in the data during production.
[Treatment] Exit every application and shut down the operating system. Then turn off machine
power and turn it on again.
If the error persists after the restart, there is the possibility of CPU failure,
memory failure and/or improper operation sequence. Stop using the machine,
take a note of the error number, and contact our service engineer or the agency.
E512831 “L4 HEAD: Recognized angle is wrong.”
[Cause] Component measurement and recognition by the L4 head output incorrect angles
during production.
[Treatment] (1) Check if the outline dimensions and pick angle are correctly specified in
component data and pick data.
(2) Exit every application and shut down the operating system. Then turn off
machine power and turn it on again.
If the error persists after the restart, there is the possibility of measurement unit
failure, recognition unit failure and/or improper operation sequence. Stop using
the machine, take a note of the error number, and contact our service engineer or
the agency.
101
E512832 “L4 HEAD: Cannot use the specified feeder for the pick position.
[Cause] The pick X coordinate of the L4 head in production is considerably different from
the specified coordinate in pick data.
[Treatment] Exit every application and shut down the operating system. Then turn off machine
power and turn it on again.
If the error persists after the restart, there is the possibility of CPU failure,
memory failure and/or improper operation sequence. Stop using the machine,
take a note of the error number, and contact our service engineer or the agency.
E512833 “L4 HEAD: An encoder counter overflow was detected while the
theta-axis was moving.”
[Cause] The encoder counter for the L4 theta-axis overflows during production.
[Treatment] Exit every application and shut down the operating system. Then turn off machine
power and turn it on again.
If the error persists after the restart, there is the possibility of CPU failure,
memory failure and/or improper operation sequence. Stop using the machine,
take a note of the error number, and contact our service engineer or the agency.
E512834 “L4 HEAD: A position deviation was detected while the theta-axis
was moving.”
[Cause] The encoder counter for the L4 theta-axis is considerably different from the angle
specified in the data during production.
[Treatment] Exit every application and shut down the operating system. Then turn off machine
power and turn it on again.
If the error persists after the restart, there is the possibility of CPU failure,
memory failure and/or improper operation sequence. Stop using the machine,
take a note of the error number, and contact our service engineer or the agency.
E512841 “R1 HEAD: Recognized angle is wrong.”
[Cause] Component measurement and recognition with the R1 head output incorrect
angles during production.
[Treatment] (1) Check if the outline dimensions and pick angle are correctly specified in
component data and pick data.
(2) Exit every application and shut down the operating system. Then turn off
machine power and turn it on again.
If the error persists after the restart, there is the possibility of measurement unit
failure, recognition unit failure and/or improper operation sequence. Stop using
the machine, take a note of the error number, and contact our service engineer or
the agency.
E512842 “R1 HEAD: Cannot use the specified feeder for the pick position.
[Cause] The pick X coordinate of the R1 head in production is considerably different from
the specified coordinate in pick data.
[Treatment] Exit every application and shut down the operating system. Then turn off machine
power and turn it on again.
If the error persists after the restart, there is the possibility of CPU failure,
memory failure and/or improper operation sequence. Stop using the machine,
take a note of the error number, and contact our service engineer or the agency.
102
E512843 “R1 HEAD: An encoder counter overflow was detected while the
theta-axis was moving.”
[Cause] The encoder counter for the R1 theta-axis overflows during production.
[Treatment] Exit every application and shut down the operating system. Then turn off machine
power and turn it on again.
If the error persists after the restart, there is the possibility of CPU failure,
memory failure and/or improper operation sequence. Stop using the machine,
take a note of the error number, and contact our service engineer or the agency.
E512844 “R1 HEAD: A position deviation was detected while the theta-axis
was moving.”
[Cause] The encoder counter for the R1 theta-axis is considerably different from the angle
specified in the data during production.
[Treatment] Exit every application and shut down the operating system. Then turn off machine
power and turn it on again.
If the error persists after the restart, there is the possibility of CPU failure,
memory failure and/or improper operation sequence. Stop using the machine,
take a note of the error number, and contact our service engineer or the agency.
E512851 “R2 HEAD: Recognized angle is wrong.”
[Cause] Component measurement and recognition with the R2 head output incorrect
angles during production.
[Treatment] (1) Check if the outline dimensions and pick angle are correctly specified in
component data and pick data.
(2) Exit every application and shut down the operating system. Then turn off
machine power and turn it on again.
If the error persists after the restart, there is the possibility of measurement unit
failure, recognition unit failure and/or improper operation sequence. Stop using
the machine, take a note of the error number, and contact our service engineer or
the agency.
E512852 “R2 HEAD: Cannot use the specified feeder for the pick position.
[Cause] The pick X coordinate of the R2 head in production is considerably different from
the specified coordinate in pick data.
[Treatment] Exit every application and shut down the operating system. Then turn off machine
power and turn it on again.
If the error persists after the restart, there is the possibility of CPU failure,
memory failure and/or improper operation sequence. Stop using the machine,
take a note of the error number, and contact our service engineer or the agency.
E512853 “R2 HEAD: An encoder counter overflow was detected while the
theta-axis was moving.”
[Cause] The encoder counter for the R2 theta-axis overflows during production.
[Treatment] Exit every application and shut down the operating system. Then turn off machine
power and turn it on again.
If the error persists after the restart, there is the possibility of CPU failure,
memory failure and/or improper operation sequence. Stop using the machine,
take a note of the error number, and contact our service engineer or the agency.