159 [Treatm ent] Pleas e select [Manual Contr ol] from the m enu bar , and then select [Contr ol(C )] [Other(O )] [AT C Control(A) ]. Set ‘Control Unit’ to ‘left ATC’, and s elect ‘Slide plate Control(A)’ f rom the ‘Cont…

100%1 / 1361
158
If the treatment1 does not work, there is a possibility that the slide
plate ON sensor is broken. It could be that the wiring came off the
connector part, that a contact pin in the connector part is broken, that
the wiring got cut off, or that the sensor itself is broken. Please
examine the wiring and connector. If any of them are broken, you
need to replace them with new ones.
If the treatment2 does not work, a PCB is broken or the wiring
between the PCBs is bad.
2. Slide plate does not work.
There is a possibility that the lock valve of the solenoid valve, that drives
the slide plate, is closed. Please make sure that the lock valve of the
solenoid valve is opened all the way.
There is a possibility that a nozzle is not installed in the ATC correctly and
that prevent the slide plate from sliding properly. Please see if nozzles are
correctly installed in the ATC.
There is a possibility that a component or implement got caught in the
sliding part of the slide plate and that prevents the slide plate from sliding
properly. Please see if there is anything on the slide plate.
There is a possibility that the air supplying pipes to the slide plate driving
cylinder have a problem. It could be that the speed controller is fully
tightened up, that the air pipe came off the cylinder, or a wrong air pipe is
connected to the cylinder. Please see the air pipes and make sure that
correct pipes are connected.
There is a possibility that the connecting part between the shaft of the
slide plate driving cylinder and the slide plate has a problem. It could be
that the nut attached to the tip of the shaft fell off, that the shaft got
chipped or broken, or that the plate got chipped or broken. You need to
have the damaged part repaired or replace it with a new one.
There is a possibility that the slide plate driving cylinder is broken. Please
stop the air supplying on the machine and see if the slide plate works fine
manually. If the plate does not work smoothly, you need to replace it with
a new one.
There is a possibility that the slide plate driving solenoid valve is broken. It
could be that the wiring came off the connector part, that a contact pin in
the connector part is broken, that the wiring got cut off, or the solenoid
valve itself is broken. Please examine the wiring and connectors. If any of
them are broken, you need to replace them with new ones..
If the treatments mentioned above do not work, a PCB is broken or the
wiring between the PCBs is bad.
E610005 “A time-out occurred when shutting the ATC(L) slide pate”
[Cause] A process to close the left ATC slide plate was taken place but the plate did not
open within a certain amount of time. The follows could be the cause.
The air is not being supplied properly.
The slide plate that slides left and right to open and close the plate in the ATC
unit does not work properly.
The sensor which detects the position of the slide plate is not tuned well or
broken.
159
[Treatment] Please select [Manual Control] from the menu bar, and then select [Control(C )]
[Other(O)] [ATC Control(A)]. Set ‘Control Unit’ to ‘left ATC’, and select ‘Slide plate
Control(A)’ from the ‘Control Item’ frame’ to open/close the slide plate. Please
perform one of the treatments below according to the result you get.
1. Slide plate works properly.
1.1 The ‘Slide plate OFF sensor’ in the ‘Status’ displaying frame gets ON/OFF.
The speed controller of the Slide plate driving cylinder might be wrung too
much toward its minimum limit. Please loosen the controller.
1.2 The ‘Slide plate OFF sensor’ in the ‘Status’ displaying frame does not get
ON/OFF.
There is a possibility that the Slide plate OFF sensor was adjusted to
out of the Cylinder’s movable range. Please re-adjust the sensor to
where it gets ON/OFF.
If the treatment1 does not work, there is a possibility that the slide
plate OFF sensor is broken. It could be that the wiring came off the
connector part, that a contact pin in the connector part is broken, that
the wiring got cut off, or that the sensor itself is broken. Please
examine the wiring and connector. If any of them are broken, you
need to replace them with new ones.
If the treatment2 does not work, a PCB is broken or the wiring
between the PCBs is bad.
2. Slide plate does not work.
There is a possibility that the lock valve of the solenoid valve, that drives
the slide plate, is closed. Please make sure that the lock valve of the
solenoid valve is opened all the way.
There is a possibility that a nozzle is not installed in the ATC correctly and
that prevent the slide plate from sliding properly. Please see if nozzles are
correctly installed in the ATC.
There is a possibility that a component or implement got caught in the
sliding part of the slide plate and that prevents the slide plate from sliding
properly. Please see if there is anything on the slide plate.
There is a possibility that the air supplying pipes to the slide plate driving
cylinder have a problem. It could be that the speed controller is fully
tightened up, that the air pipe came off the cylinder, or a wrong air pipe is
connected to the cylinder. Please see the air pipes and make sure that
correct pipes are connected.
There is a possibility that the connecting part between the shaft of the
slide plate driving cylinder and the slide plate has a problem. It could be
that the nut attached to the tip of the shaft fell off, that the shaft got
chipped or broken, or that the plate got chipped or broken. You need to
have the damaged part repaired or replace it with a new one.
There is a possibility that the slide plate driving cylinder is broken. Please
stop the air supplying on the machine and see if the slide plate works fine
manually. If the plate does not work smoothly, you need to replace it with
a new one.
There is a possibility that the slide plate driving solenoid valve is broken. It
could be that the wiring came off the connector part, that a contact pin in
the connector part is broken, that the wiring got cut off, or the solenoid
valve itself is broken. Please examine the wiring and connectors. If any of
them are broken, you need to replace them with new ones..
If the treatments mentioned above do not work, a PCB is broken or the
wiring between the PCBs is bad.
160
E610006 “A time-out occurred when shutting the ATC(R) slide plate”
[Cause] A process to close the right ATC slide plate was taken place but the plate did not
open within a certain amount of time. The follows could be the cause.
The air is not being supplied properly.
The slide plate that slides left and right to open and close the plate in the ATC
unit does not work properly.
The sensor which detects the position of the slide plate is not tuned well or
broken.
[Treatment] Please select [Manual Control] from the menu bar, and then select [Control(C )]
[Other(O)] [ATC Control(A)]. Set ‘Control Unit’ to ‘right ATC’, and select ‘Slide
plate Control(A)’ from the ‘Control Item’ frame’ to open/close the slide plate.
Please perform one of the treatments below according to the result you get.
1. Slide plate works properly.
1.1 The ‘Slide plate OFF sensor’ in the ‘Status’ displaying frame gets ON/OFF.
The speed controller of the Slide plate driving cylinder might be wrung too
much toward its minimum limit. Please loosen the controller.
1.2 The ‘Slide plate OFF sensor’ in the ‘Status’ displaying frame does not get
ON/OFF.
There is a possibility that the Slide plate OFF sensor was adjusted to
out of the Cylinder’s movable range. Please re-adjust the sensor to
where it gets ON/OFF.
If the treatment1 does not work, there is a possibility that the slide
plate OFF sensor is broken. It could be that the wiring came off the
connector part, that a contact pin in the connector part is broken, that
the wiring got cut off, or that the sensor itself is broken. Please
examine the wiring and connector. If any of them are broken, you
need to replace them with new ones.
If the treatment2 does not work, a PCB is broken or the wiring
between the PCBs is bad.
2. Slide plate does not work.
There is a possibility that the lock valve of the solenoid valve, that drives
the slide plate, is closed. Please make sure that the lock valve of the
solenoid valve is opened all the way.
There is a possibility that a nozzle is not installed in the ATC correctly and
that prevent the slide plate from sliding properly. Please see if nozzles are
correctly installed in the ATC.
There is a possibility that a component or implement got caught in the
sliding part of the slide plate and that prevents the slide plate from sliding
properly. Please see if there is anything on the slide plate.
There is a possibility that the air supplying pipes to the slide plate driving
cylinder have a problem. It could be that the speed controller is fully
tightened up, that the air pipe came off the cylinder, or a wrong air pipe is
connected to the cylinder. Please see the air pipes and make sure that
correct pipes are connected.
There is a possibility that the connecting part between the shaft of the
slide plate driving cylinder and the slide plate has a problem. It could be
that the nut attached to the tip of the shaft fell off, that the shaft got
chipped or broken, or that the plate got chipped or broken. You need to
have the damaged part repaired or replace it with a new one.
There is a possibility that the slide plate driving cylinder is broken. Please
stop the air supplying on the machine and see if the slide plate works fine
manually. If the plate does not work smoothly, you need to replace it with
a new one.
There is a possibility that the slide plate driving solenoid valve is broken. It
could be that the wiring came off the connector part, that a contact pin in