KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第990页

185 [Treatm ent] Pleas e turn of f the power supply of your machine. If the error oc curs even af ter the reboot, please see if the cables are connected pr operly. If the error st ill occurs even when the cables are conn…

100%1 / 1361
184
E610233 “RZ2 Driver alarm occurred”
[Cause] An abnormal matter happened to the Z axis servo driver on the right head2.
[Treatment] Please turn off the power supply of your machine. If the error occurs even after
the reboot, please see if the cables are connected properly. If the error still occurs
even when the cables are connected properly, you need to replace the Z axis
servo driver on the right head2 with a new one.
E610234 “RZ3 Driver alarm occurred”
[Cause] An abnormal matter happened to the Z axis servo driver on the right head3.
[Treatment] Please turn off the power supply of your machine. If the error occurs even after
the reboot, please see if the cables are connected properly. If the error still occurs
even when the cables are connected properly, you need to replace the Z axis
servo driver on the right head3 with a new one.
E610235 “RZ4 Driver alarm occurred”
[Cause] An abnormal matter happened to the Z axis servo driver on the right head4.
[Treatment] Please turn off the power supply of your machine. If the error occurs even after
the reboot, please see if the cables are connected properly. If the error still occurs
even when the cables are connected properly, you need to replace the Z axis
servo driver on the right head4 with a new one.
E610236 “LT1 Driver alarm occurred”
[Cause] An abnormal matter happened to the Theta axis servo driver on the left head1.
[Treatment] Please turn off the power supply of your machine. If the error occurs even after
the reboot, please see if the cables are connected properly. If the error still occurs
even when the cables are connected properly, you need to replace the Theta axis
servo driver on the left head1 with a new one.
E610237 “LT2 Driver alarm occurred”
[Cause] An abnormal matter happened to the Theta axis servo driver on the left head2.
[Treatment] Please turn off the power supply of your machine. If the error occurs even after
the reboot, please see if the cables are connected properly. If the error still occurs
even when the cables are connected properly, you need to replace the Theta axis
servo driver on the left head2 with a new one.
E610238 “LT3 Driver alarm occurred”
[Cause] An abnormal matter happened to the Theta axis servo driver on the left head3.
[Treatment] Please turn off the power supply of your machine. If the error occurs even after
the reboot, please see if the cables are connected properly. If the error still occurs
even when the cables are connected properly, you need to replace the Theta axis
servo driver on the left head3 with a new one.
E610239 “LT4 Driver alarm occurred”
[Cause] An abnormal matter happened to the Theta axis servo driver on the left head4.
[Treatment] Please turn off the power supply of your machine. If the error occurs even after
the reboot, please see if the cables are connected properly. If the error still occurs
even when the cables are connected properly, you need to replace the Theta axis
servo driver on the left head4 with a new one.
E610240 “RT1 Driver alarm occurred”
[Cause] An abnormal matter happened to the Theta axis servo driver on the right head1.
185
[Treatment] Please turn off the power supply of your machine. If the error occurs even after
the reboot, please see if the cables are connected properly. If the error still occurs
even when the cables are connected properly, you need to replace the Theta axis
servo driver on the right head1 with a new one.
E610241 “RT2 Driver alarm occurred”
[Cause] An abnormal matter happened to the Theta axis servo driver on the right head2.
[Treatment] Please turn off the power supply of your machine. If the error occurs even after
the reboot, please see if the cables are connected properly. If the error still occurs
even when the cables are connected properly, you need to replace the Theta axis
servo driver on the right head2 with a new one.
E610242 “RT3 Driver alarm occurred”
[Cause] An abnormal matter happened to the Theta axis servo driver on the right head3.
[Treatment] Please turn off the power supply of your machine. If the error occurs even after
the reboot, please see if the cables are connected properly. If the error still occurs
even when the cables are connected properly, you need to replace the Theta axis
servo driver on the right head3 with a new one.
E610243 “RT4 Driver alarm occurred”
[Cause] An abnormal matter happened to the Theta axis servo driver on the right head4.
[Treatment] Please turn off the power supply of your machine. If the error occurs even after
the reboot, please see if the cables are connected properly. If the error still occurs
even when the cables are connected properly, you need to replace the Theta axis
servo driver on the right head4 with a new one.
E610300 “An error occurred when ComRes command send”
[Cause] Command sending of Command-response type failed. This is an error that
occurred during the data communication in the machine.
[Treatment] Please turn off the power supply of your machine and reboot it.
If the error occurred after the installation or the versionup of the software, you
need to re-install the software.
If the treatments above do not work, there is a possibility that board(s) in the
machine is broken. You need to replace it(them) with new ones.
E610301 “An error occurred when ComRes response receive”
[Cause] Response reception of Command-Response type failed. This is an error that
occurred during the data communication in the machine.
[Treatment] Please turn off the power supply of your machine and reboot it.
If the error occurred after the installation or the versionup of the software, you
need to re-install the software.
If the treatments above do not work, there is a possibility that board(s) in the
machine is broken. You need to replace it(them) with new ones.
186
E610400 “Vacuum of L1 head has been on”
[Cause] A nozzle returning was requested while the vacuum of the left head1 is still ON.
There is a possibility that a component is being picked by the head.
[Treatment] Please take the component off the head, then turn off the vacuum before
returning the nozzle.
E610401 “Vacuum of L2 head has been on”
[Cause] A nozzle returning was requested while the vacuum of the left head2 is still ON.
There is a possibility that a component is being picked by the head.
[Treatment] Please take the component off the head, then turn off the vacuum before
returning the nozzle.
E610402 “Vacuum of L3 head has been on”
[Cause] A nozzle returning was requested while the vacuum of the left head3 is still ON.
There is a possibility that a component is being picked by the head
[Treatment] Please take the component off the head, then turn off the vacuum before
returning the nozzle.
E610403 “Vacuum of L4 head has been on”
[Cause] A nozzle returning was requested while the vacuum of the left head4 is still ON.
There is a possibility that a component is being picked by the head.
[Treatment] Please take the component off the head, then turn off the vacuum before
returning the nozzle.
E610404 “Vacuum of R1 head has been on”
[Cause] A nozzle returning was requested while the vacuum of the right head1 is still ON.
There is a possibility that a component is being picked by the head.
[Treatment] Please take the component off the head, then turn off the vacuum before
returning the nozzle.
E610405 “Vacuum of R2 head has been on”
[Cause] A nozzle returning was requested while the vacuum of the right head2 is still ON.
There is a possibility that a component is being picked by the head.
[Treatment] Please take the component off the head, then turn off the vacuum before
returning the nozzle.
E610406 “Vacuum of R3 head has been on”
[Cause] A nozzle returning was requested while the vacuum of the right head3 is still ON.
There is a possibility that a component is being picked by the head.
[Treatment] Please take the component off the head, then turn off the vacuum before
returning the nozzle.
E610407 “Vacuum of R4 head has been on”
[Cause] A nozzle returning was requested while the vacuum of the right head4 is still ON.
There is a possibility that a component is being picked by the head.
[Treatment] Please take the component off the head, then turn off the vacuum before
returning the nozzle.
E610408 “The specified nozzle has been installed”
[Cause] The nozzle requested to be installed has been already loaded on the head. The
request of the nozzle installation is not necessary.
[Treatment] This process can not be performed.