1OM-1603-006_w.pdf - 第129页
1OM-1603 3-4 1. Automatic Operation : Chap.3 1003-003 1.1.4 SafetyConrmationofMachineSurroundings Check the surroundings of the machine and conrm safety before starting the automatic operation. CAUTION Before oper…

1OM-1603
3-3
1. Automatic Operation : Chap.3
1012-005
1.1.3 ConrmationofCoverSection
DANGER
There are strong motorized and high-voltage areas
inside the machine. Special caution should be paid
not to touch them.
Doing otherwise will cause personal injury (serious
accident).
•
Onlyqualiedmaintenancepersonnelshould
detach the covers.
•
The machine should be operated with the covers
being attached.
•
If a cover is detached, be sure to reattach it.
•
Be sure to close the transparent covers (door type)
before operating the machine.
•
Do not disengage the interlock mechanism of the
transparent covers (door type).
Conrm that the transparent covers above the beams, the safety covers around the
base, the storage cover of electrical part box (located around the base) are closed.
Safety Cover
(located around the base)
Transparent Covers
(Door Type, located over
the beams)
Transparent Covers
(Door Type, located over the beams)
Storage Cover of
Electrical Part Box
(located around the base)
Safety Cover
(located around the base)
Machine Front Side
F1C3

1OM-1603
3-4
1. Automatic Operation : Chap.3
1003-003
1.1.4 SafetyConrmationofMachineSurroundings
Check the surroundings of the machine and conrm safety before starting the
automatic operation.
CAUTION
Before operating the machine, conrm that there are no
people around the machine (especially, the other side of
the machine operation) and no objects such as tools and
parts are left around the machine.

1OM-1603
3-5
1. Automatic Operation : Chap.3
1003-003
1.2 Preparation before Automatic Operation
1.2.1 Power ON
Procedure
(1) Remove the padlock from the lock lever of the power breaker located on the
front side of the machine.
Power Breaker
Lock Lever
Padlock
F1C4
(2) Set the power breaker to "ON".
(Power is supplied to the machine.)
Power Supply
F1C5
NOTICE
When the power must be supplied again, wait for
approximately 10 seconds after the power breaker is
set to "OFF", then set the breaker to "ON".
If the power breaker is set to "ON" soon after being set
to "OFF", the data collected before the power is turned
off will not be reset, causing the machine to malfunction
occasionally.