Station Software 706.1 / Installation Manual Ausgabe 11/2012 Edition
8
3 Upgrading to the 706.1 Software Version
This chapter describes which steps you have to attend when upgrading from different software
versions.
When upgrading the station software, always check the eSW versions and download the current
versions if necessary.
With the installation of the 706.1 station software, statistic data (maintenance
intervals) is registered for the CPP and C&P20A placement heads and the SX main
axis. In order to achieve a defined initial state for the maintenance due, the
correspondent maintenance operations have to be performed on the subsystems
after the software installation.
An upgrade of the embedded software is necessary for the LDU-X. Generally, it is
not possible to perform a download of the embedded software via the station
software for the LDU-X. The LDU-X has to be upgraded to the 2.02 software version
with the aid of an external PC.
There is new embedded software for the feeders. As soon as a feeder with an elder
eSW is set up an update of the eSW is proposed. This can be cancelled but it is not
possible to take out the table as long as the update is pending. To get the table out
without a download you have to take out the feeders or disable the feeder download
within the SW options.
There is new embedded software for CPP and C&P20 placement heads. After an
update from a lower version they are recognized as modified heads and the head
3.1 Upgrading from the 705.xx Software Version
SX1/SX2 and DX1/DX2 placement machines in the field with an FC camera at Location 1:
Due to an error correction in the configuration, the FC camera position has been moved and
thus the calibration values for the camera and the segment offset are invalid.
Recalibrate the camera and the segment offset.
Station Software 706.1 / Installation Manual Ausgabe 11/2012 Edition
9
3.2 Upgrading from the 704.xx Software Version
SX1/SX2 placement machines in the field with an FC camera at Location 1:
Due to an error correction in the configuration, the FC camera position has been moved and
thus the calibration values for the camera and the segment offset are invalid.
Recalibrate the camera and the segment offset.
Recalibrate the travel ranges.
Recalibrate the external cameras.
This is required, as the z height has been adapted for the dp calibration.
Save the calibration data for the placement heads (except Twin Head) in the EEPROM
(see section 7.9).
Perform a component sensor calibration if a CPP placement head is used for 0201/01005
placement.
Perform the closed vacuum calibration if Twin Heads are used.
3.3 Upgrading from the 703.02 or 703.02 SP1 Software Version
SX1/SX2 placement machines in the field with an FC camera at Location 1:
Due to an error correction in the configuration, the FC camera position has been moved and
thus the calibration values for the camera and the segment offset are invalid.
Recalibrate the camera and the segment offset.
Please pay attention to the Technical Information TI2010-10V02 and TI2010-10C02 when you
download the embedded software.
Recalibrate the travel ranges.
Recalibrate the external cameras.
This is required, as the z height has been adapted for the dp calibration.
SX-series placement machines in the field:
Due to the SW component counter, the HCU/GCU and the sensor modules have to be
programmed. For this, perform the work steps that are described in the Technical Information
TI2010-02V01 and TI2010-02C01 about programming HCU/GCU for the 704 upgrade. These
work steps can only be performed by the SIPLACE Service.
SX 1/2 placement machine:
In order to use the "Long Board" option and the "Gantry Modularity" functionality, PCB mapping
and head mapping have to be performed.
Placement machines with FC camera:
The entire placement head has to be calibrated.
X4I placement machine:
The machine zero points, tables, nozzle changers, PCB reference corners and, if stationary
cameras are present the placement heads as well, have to be recalibrated (due to a changed
handling of double zero points on the X4I placement machine). No mapping is necessary.
Save the calibration data for the placement heads (except Twin Head) in the EEPROM
(see section 7.9).
Perform a component sensor calibration if a CPP placement head is used for 0201/01005
placement.
Perform the closed vacuum calibration if Twin Heads are used.
Station Software 706.1 / Installation Manual Ausgabe 11/2012 Edition
10
3.4 Upgrading from the 703.01 Software Version
Please pay attention to the Technical Information TI2010-10V02 and TI2010-10C02 when you
download the embedded software.
Recalibrate the travel ranges.
Recalibrate the external cameras.
This is required, as the z height has been adapted for the dp calibration.
3.4.1 SX-Series Placement Machines
SX1/SX2 placement machines in the field with an FC camera at Location 1:
Due to an error correction in the configuration, the FC camera position has been moved and
thus the calibration values for the camera and the segment offset are invalid.
Recalibrate the camera and the segment offset.
SX-series placement machines in the field:
Due to the SW component counter, the HCU/GCU and sensor modules have to be
programmed. For this, perform the work steps that are described in the Technical Information
TI2010-02V01 and TI2010-02C01 about programming HCU/GCU for the 704 upgrade. These
work steps can only be performed by the SIPLACE Service.
Exchange the X/Y sensor modules to X-03068500-03 / Y-03064608-03.
Install the 706.1 station software.
Shut down the machine.
Remove the tables.
Switch on the machine again and wait until all error messages have been displayed and the
eSW download menu is enabled.
Perform the eSW download for all subsystems.
Reboot the machine.
Place the tables.
The eSW download for the feeders starts automatically.
Save the calibration data for the placement heads (except Twin Head) in the EEPROM
(see section 7.9).
Perform a component sensor calibration if a CPP placement head is used for 0201/01005
placement.
Perform the closed vacuum calibration if Twin Heads are used.
Calibrate the machine by performing the following steps:
Calibrate the gantry axis (activate the options Y-axis: Encoder Alignment, Travel range,
X-axis: Parameterization, Y-axis: Mapping in the list).
Perform PCB and head mapping.
Start the production.