HS-50 Modification Long Board Option 2 Assembly instructions Long Board Option SIPLACE HS-50 03/2007 Edition 25 2 Assembly instructions Long Board Option SIPLACE HS-50 This option is used to process overlong PCBs on the …
1 Montageanleitung Modifikation Lange Leiterplatte SIPLACE HS-50 Lange Leiterplatte HS-50
Ausgabe 03/2007
24
HS-50 Modification Long Board Option 2 Assembly instructions Long Board Option SIPLACE HS-50
03/2007 Edition
25
2 Assembly instructions Long Board
Option SIPLACE HS-50
This option is used to process overlong PCBs on the SIPLACE HS-50 by placing the front half of
the PCB in placement area 1 and the rear half in placement area 2. This is done by moving the
stopper to the output conveyor.
The new stopper can be fitted at different positions to suit the length of the PCB.
The offset from the default stopper is entered in the station configuration on the line computer.
The minimum PCB width is 100 mm, or 140 mm at position three. 2
2.1 Parts required
2.1.1 Tools and consumables required
– Set of hexagon socket spanners
– Cable stripper
– Crimping tool (AMP)
2.1.2 Assembly kit Long Board Option SIPLACE HS-50 (Item no: 00119405-01)
- LBO HS-50 (MS) Item no. 00372363-01 1x
- Option CD for enabling the function
on the line computer Item no. 00369764-02-01 1x
- Assembly instructions LBO HS-50 Item no. 00193431-xx 1x
2.2 Requirements
Station software version: 503.01 or later 2
2.3 Restrictions
(see section 5.1.3 in the software version description LCU 503.01). 2
– the function can only be activated for both conveyor tracks at the same time, i.e. it is not pos-
sible to process one normal and one long PCB together on a dual conveyor.
– if this option is selected, then the "whispering down the line" option is automatically deactiva-
ted.

2 Assembly instructions Long Board Option SIPLACE HS-50 HS-50 Modification Long Board Option
03/2007 Edition
26
2.4 Safety instructions
WARNING
Comply with the higher ranking "Safety Instructions" in Chapter "Operational Safety" in the User
Manual and Service Manual. 2
The placement machines SIPLACE are powered by mains voltage.
Portions of the system are therefore conducting dangerous electricity, inside the machine even
while the master switch is turned off.
Death, serious injury or considerable damage may result if these automatic placement systems
are handled incorrectly.
After you have properly carried out the shut-down of the operating system:
Before all work the machine must be turned off at the main switch and isolated from the mains. In
addition, the compressed air supply must be turned off at the main valve of the compressed air
unit in the machine base and the compressed air lines must be bled by actuating the needle valve
at the compressed air unit.
Danger: For anyone wearing a heart pacemaker it is not permitted to work near linear motors, as
described in detail in the User Manual and the Service Manual, Chapter "Special Safety Instruc-
tions when working in vivinty of powerful magnetic fields" .
Obey the applicable accident prevention regulations, DIN standards and special safety codes of
your country at all times. DIN EN 60204 must be adhered to during all work inside the machine
base.
Follow the instructions regarding residual voltages in Chapter "Operational Safety".
Comply with regulations on ESDs (see Chapter "Operational Safety").
During the work of assembly secure the machine conscientiously against other personnel and pre-
vent it from being turned back on without authorization, as described in the User Manual in the
chapter "Locking the Machine...".
There is additional, higher risk of accident when working with the SITEST program.
The SITEST program is only to be started by personnel who are authorized to do so. 2
2
2.4.1 Definitions
2
Please note 2
2
2
2
Caution 2