HS-50 Modification Long Board Option 2 Assembly instructions Long Board Option SIPLACE HS-50 03/2007 Edition 41 2 2 : Plug the cables in at the appropriate position s (see diagrams above and below). : Close the protectiv…

100%1 / 46
2 Assembly instructions Long Board Option SIPLACE HS-50 HS-50 Modification Long Board Option
03/2007 Edition
40
2.1.3 Connector pin assignments
: Run the cables through the power chain and cable ducts to the PCB transport controller board.
: Strip the individual wires back by approx. 3 mm.
: Crimp the contacts onto the individual wires and check the coding.
: Attach the plugs to the stripped cable ends as shown in the following photographs.
2
2
Views from above (cable side):
Valve actuator connection
Plug: X12
Cable length: 160 cm
Brown
White
Not used
(no coding)
Coding
PCB stopper valve (BERO) connection
Plug: X11
Cable length: 200 cm
Brown
White
Coding
HS-50 Modification Long Board Option 2 Assembly instructions Long Board Option SIPLACE HS-50
03/2007 Edition
41
2
2
: Plug the cables in at the appropriate positions (see diagrams above and below).
: Close the protective covers.
: Switch the placement machine on at the main switch.
2
Light sensor WT4-2P330 connection
Plug: X16
cable length: 190 cm
White
Key
Coding plug: X19
Jumper
Brown
Black
Blue
Key
2 Assembly instructions Long Board Option SIPLACE HS-50 HS-50 Modification Long Board Option
03/2007 Edition
42
2.2 Software
2.2.1 SITEST
: Switch to the SITEST program.
: Select “Conveyor” –> “PCB conveyor”.
: Change the transport mode: Select “Long PCB with additional stopper” and confirm your sel-
ection.
: Start the station software.
2.2.2 Line computer
: Load the options from the CD-ROM.
: In the station configuration / component editor, activate “Long PCB” under PCB conveyor.
2
2