00192375-01 - 第114页
SIPLACE GEM for S25, HS50 SW Version GEM 502.01 HOST Inter face Manual Page 114 of 236 ©Siemens AG, all rights reserved This mes sage occ urs whether or not the Hos t has enabled event repor ting for this CEID (see S2F37…

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 113 of 236
If the CEID is enabled, but no Reports are linked to this CEID, S6F11 has the following
special format:
S6F13 W * H<-E
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L>
> .
6)$QQRWDWHG(YHQW5HSRUW
S6F14 * H->E
<B [1] 00> . * ACKC6
The Host acknowledges the Event Report. The Equipment ignore ACKC6.
6)(YHQW5HSRUW5HTXHVW
S6F15 W * H->E
<U4 CEID> . * Collection Event ID
The Host sends the CEID of interest, requesting normal format reports.
6)(YHQW5HSRUW'DWD
S6F16 * H<-E, Multiblock
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L
<L [2]
<U4 RPTID> * Report ID
<L
<V> * Variable Value
...
>
>
...
>
> .
The Equipment sends one or more Event Reports which the Host has previously linked to
that CEID (see S2F35). Each report contains specific Variables which the Host has
previously defined for that Report (see S2F33).

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 114 of 236 ©Siemens AG, all rights reserved
This message occurs whether or not the Host has enabled event reporting for this CEID
(see S2F37), and regardless of how the Host has set the Equipment Constant RpType
(report format).
The Equipment generates a meaningless value for DATAID.
CEID contains the CEID specified in S6F15.
If the CEID specified in S6F15 is invalid, or if no reports are linked to this CEID, this
message has the following special format:
S6F16 * H<-E, Multiblock
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L>
> .
6)$QQRWDWHG(YHQW5HSRUW5HTXHVW
S6F17 W * H->E
<U4 CEID> . * Collection Event ID
The Host sends the CEID of interest, requesting annotated format reports.
6)$QQRWDWHG(YHQW5HSRUW'DWD
S6F18 * H<-E
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L
<L [2]
<U4 RPTID> * Report ID
<L
<L [2]
<U4 VID> * Variable ID
<V> * Variable Value
>
...
>
>
...
>
> .

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 115 of 236
The Equipment sends one or more Event Reports which the Host has previously linked to
that CEID (see S2F35). Each report contains specific Variables which the Host has
previously defined for that Report (see S2F33).
This message occurs whether or not the Host has enabled event reporting for this CEID
(see S2F37), and regardless of how the Host has set up the Equipment Constant RpType
(report format).
The Equipment generates a meaningless value for DATAID.
CEID contains the CEID specified in S6F17.
If the CEID specified in S6F17 is invalid, or if no reports are linked to this CEID, this
message has the following format:
S6F18 * H<-E, Multiblock
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L>
> .
6)5HTXHVW5HSRUW5HTXHVW
S6F19 W * H->E
<U4 RPTID> . * Report ID
The Host requests a Report for the specified RPTID.
6)5HTXHVW5HSRUW'DWD
S6F20 * H<-E, Multiblock
<L
<V>
...
> .
The Equipment sends the Report.
If no report is defined for the RPTID in S6F19, S6F20 has the following special error
format:
S6F20 * H<-E
<L> .
6)5HTXHVW$QQRWDWHG5HSRUW5HTXHVW
S6F21 W * H->E
<U4 RPTID> . * Report ID
The Host requests an Annotated Report for the specified RPTID.