SIPLACE GEM for S25, HS50 SW Version GEM 502.01 HOST Inter face Manual ©Siemens AG, all rights reserved page 161 of 236 9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLR Q After s tartup this is the revision num ber of …

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 160 of 236 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
1002044 SV U1 SPOOLUNLOADSUBSTATE.
The current spool state within the SPOOL UNLOAD
super-state.
3 = Purge Spool
4 = Transmit Spool
5 = No Spool
1002045 EC U1 CONFIGSPOOL.
This EC determines whether spooling is enabled or
disabled for this Equipment.
0 = Disabled
1 = Enabled
1002046 EC BOOL OVERWRITESPOOL.
This EC determines the action to be taken by the
Equipment when the Spool file reaches its capacity.
TRUE = Overwrite Spool
FALSE = Do Not Overwrite Spool
Limit Monitoring
1002047 DV U4 GEMLIMITSVID.
The VID relating to the most recent Limits Monitoring
transition event which occurred.
1002048 DV B[1] GEMEVENTLIMIT.
The LIMITID relating to the most recent Limits
Monitoring transition event which occurred.
1002049 DV B[1] GEMTRANSTYPE.
Transition type relating to the most recent Limits
Monitoring transition which occurred.
0x00 = Lower -> Upper
0x01 = Upper -> Lower
1002050 EC U2 GEMLIMITSTIMER.
The time in seconds this equipment will pauses
between checking for Limits Monitoring transitions
On-Line Identification
1002051 SV A[6] MDLN.
Model number. Ä+6ÄorÄ6Ä
1002052 SV A[6] SOFTREV.
Software revision number. [[
Miscellaneous
1002054 SV A SOFTWAREREVTABLE
Revision of feeder table software

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 161 of 236
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
After startup this is the revision number of the first
table. Will be updated with every event TableDownload
(2010008).
1002055 EC U2 HEARTBEAT.
The time in seconds that the Equipment will pause
before sending S1F1 to test the link. Units are
seconds. Valid values are 0-3200 (a setting of zero
will disable the heartbeat).
1002065 EC U1 GEMTIMEFORMAT
Format of TIME (VID 1002023)
0: 12 digits
1: 16 digits (Year 2000 compliant)
1002067 SV A[30] SOFTWAREREVGEM
GEM Software revision number. [[
1002068 EC A[10] NICKNAME
Default value is "SIPLACE"
Can be overwritten with an individual name for each
machine.
1002069 SV I8 LASTERRORCODE
If the General Error Event FM_GENERAL is used, this
Variable contains the Error Code. The Error Code is
identical to the CEID of the specific Error Event.
Example:
A barcode reading error can be reported with the
Event
CEID 920001 FM_LP_BC_NOK
or with the General Error Event
CEID 1001024 FM_GENERAL and the Variables
VID 1002069 LASTERRORCODE = 920001 and
VID 1002070 LASTFMTEXT = "FM_LP_BC_NOK"
1002070 SV A LASTFMTEXT
Error Text of the last specific Error Event. For a
detailed description see LASTERRORCODE
1002071 SV A SOFTWAREREVMTC
Software revision of the Matrix Tray Changer
Only valid after a download of the MTC firmware.
Process Program Management
1002080 SV A CURRENTSETUP
Name of current setup loaded in machine
An empty text indicates an error.

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 162 of 236 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
1002081 SV A FIRSTCURRENTPLACEPROGRAM
Name of current placement program loaded in
machine for Processing 1 Area.
An empty text indicates an error.
1002082 SV A SECONDCURRENTPLACEPROGRAM
Name of current placement program loaded in
machine for Processing 2 Area.
An empty text indicates an error.
GUI
1122001 SV A GUIACTIONTEXT
Last „Action text“ sent to GUI
An empty text indicates an error
1122002 SV A GUISTATETEXT
Last „State text“ sent to GUI
An empty text indicates an error
1122007 SV U4 GUIMESSAGENUMBER
Used for General GUI Events CEID 1120300 and
1120301
Contains the CEID of the special GUI Event.
E.g. in case of GUIStart you may use either Event
1120007 GUIStart or Event MessageFromGuiGeneral
with VID 1122007 (GUIMESSAGENUMBER) which
will contain the value 1120007.
SIPLACE Revolver Head 1
1312001 SV I4 HEIGHTREV1
Height of revolver head 1. Only valid after reference
run. Units are 1/1000 mm
During the reference run the SIPLACE measures the
distance between the upper edge of the conveyor belt
and the nozzle on segment 1. The
HEIGHTREVOLVER1 is then calculated by subtracting
the length of the nozzle on segment 1 from the
measured value. The nozzle length is defined in the
machine data. So HEIGHTREVOLOR1 is a relative
not an absolute value.
A value of 0 indicates an error
1312002 SV L GANTRYINFOREV1
Gantry information for revolver head 1. The data is
automatically reseted when a PCB reaches the center
conveyor.