00192375-01 - 第173页
SIPLACE GEM for S25, HS50 SW Version GEM 502.01 HOST Inter face Manual ©Siemens AG, all rights reserved page 173 of 236 9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLR Q A value of 0 indicates an error . 2012017 SV U2…

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 172 of 236 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
$5HIHUHQFH'HVLJQDWRU!
$&RPSRQHQW1DPH!
83DFNDJH)RUP1XPEHU!
83ODFHPHQW5HVXOW!
,3ODFHPHQW9DFXXP!>PEDU@
8'DWD9DOLG!
,;GHYLDWLRQ!>PP@
,<GHYLDWLRQ!>PP@
)$QJOH!>GHJUHHV@
)0D[/HDG'HY!
)0D[%DOO'HY!
!
IRUHDFKVHJPHQW
!
The first element in this list refers to segment 1, the
second to segment 2 and so on. If a segment was not
in use in the last placement cycle the list for that
segment is left empty.
Miscellaneous
2012013 SV U2 ERRORTYPE
Type of the most recent error
2 Transport
3Track error
4 Machine error
5 Miscellaneous
A value of 0 indicates an error.
2012014 SV U2 GANTRYONERROR
Gantry associated with the most recent error (1...4)
A value of 0 indicates an error.
2012015 SV U2 SEGMENTONERROR
Segment number associated with the most recent
error (1...12)
A value of 0 indicates an error.
2012016 SV U2 TRACKONERROR
Track number associated with the most recent error
event

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 173 of 236
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
A value of 0 indicates an error.
2012017 SV U2 ERRORINFO1
Additional information about an error event.
Corresponds to the first parameter of an error
message on the station computer.
2012018 SV U2 ERRORINFO2
Additional information about an error event.
Corresponds to the second parameter of an error
message on the station computer.
2012021 SV L GANTRYHEADCONFIG
/
/
,*DQWU\*URXS,'
/
/
,*DQWU\,'!
,7\SH2I*DQWU\!
/
/
,+HDG,'!
,+($'7<3(!
!
!
!
!
!
TypeOfGantry:
At the moment there is only 1 Type of Gantry.
TypeOfGantry is always = 1
HEADTYPE:
5 = Revolverhead with 12 nozzles
6 = Revolverhead with 6 nozzles
7 = IC Head
For a detailed description of the data item see „4.2
Data Item Dictionary“.
2012022 DV U1 MACHINESIDE

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 174 of 236 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
For a detailed description of the data item see „4.2
Data Item Dictionary“.
2012023 DV I2 TRACKNUMBER
For a detailed description of the data item see „4.2
Data Item Dictionary“.
2012024 DV I2 DIVISION
For a detailed description of the data item see „4.2
Data Item Dictionary“.
2012025 DV I2 LEVEL
For a detailed description of the data item see „4.2
Data Item Dictionary“.
2012026 DV U1 SEGMENT
For a detailed description of the data item see „4.2
Data Item Dictionary“.
2012027 DV A COMPONENTNAME
For a detailed description of the data item see „4.2
Data Item Dictionary“.
2012028 DV U2 GANTRYID
For a detailed description of the data item see „4.2
Data Item Dictionary“.
2012029 DV U2 GANTRYGROUPID
For a detailed description of the data item see „4.2
Data Item Dictionary“.
2012030 DV U2 HEADID
For a detailed description of the data item see „4.2
Data Item Dictionary“.
2012031 DV A REFERENCEDESIGNATOR
For a detailed description of the data item see „4.2
Data Item Dictionary“.
2012032 DV U2 PACKAGEFORMNUMBER
For a detailed description of the data item see „4.2
Data Item Dictionary“.
2012033 DV U2 PLACEERRORDESCRIPTION
For a detailed description of the data item see „4.2
Data Item Dictionary“.
2012035 DV U1 LOCATION
For a detailed description of the data item see „4.2
Data Item Dictionary“.
2012037 SV L PICKUPERRORSLOC1
Pick-Up Errors of location 1 (see 1.6 machine areas).
This data item will be reset when a new Process
Program is downloaded to a SIPLACE machine for the
corresponding processing area: