SIPLACE GEM for S25, HS50 SW Version GEM 502.01 HOST Inter face Manual ©Siemens AG, all rights reserved page 181 of 236 9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLR Q 2312005 SV L NOZZLECONF 3 Nozz le configuration…

100%1 / 236
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 180 of 236 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ

!
The first element in this list refers to segment 1, the
second to segment 2 and so on. If a segment was not
in use in the last placement cycle the list for that
segment is left empty
For a detailed description of the data item see 4.2
Data Item Dictionary.
An empty list indicates an error.
2312004 SV L PICKUPINFOREV3
Pick-up information for revolver head 3
/
/
$&RPSRQHQW1DPH!
,7UDFN1XPEHU!
8)HHGHU7\SH!
,/HYHO!
,'LYLVLRQ!
8/RFDWLRQ!
83LFN8S5HVXOW!
,3LFN8S9DFXXP!>PEDU@
L9DFXXP!
!

!
The first element in this list refers to segment 1, the
second to segment 2 and so on. If a segment was not
in use in the last pick up cycle the list for that segment
is left empty.
If the component was picked up from a feeder /HYHO
will contain -1.
In the case that the component was picked up from a
tray in the matrix tray changer 7UDFN1XPEHUwill
contain the 7RZHU of the MTC1,2). In this way
PICKINFOREVx has the same format as in previous
versions.
For a detailed description of the data item see 4.2
Data Item Dictionary.
An empty list indicates an error.
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 181 of 236
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
2312005 SV L NOZZLECONF3
Nozzle configuration on revolver head 3. Only valid
after reference run.
/
/
812==/(B7<3(!
,5($/B12==/(B/(1*7+!>PP@
!

!
The nozzle length is measured during the reference
run. It depends on the HEIGHTREVOLVER3 value. So
REAL_NOZZLE_LENGTH is not a absolute but a
relative value.
It is calculated by subtracting the measured distance
between the nozzle and the upper edge of the
transport conveyor from the HEIGHTREVOLVER3
value.
An empty list indicates an error.
For a detailed description of the data item see 4.2
Data Item Dictionary.
2312006 SV L VACUUMDATAREV3
Vacuum measurements from the last reference run on
revolver head 3. Valid only after reference run.
/
/
,RSHQBQR]]OH!>PEDU@
,FORVHGBQR]]OH!>PEDU@
,FXELFBQR]]OH!>PEDU@
,QRWBFXELFBQR]]OH!>PEDU@
,WROBGLUW\BQR]]OH!>PEDU@
,WROBOHDN\BQR]]OH!>PEDU@
!

!
The first element in this list refers to segment 1, the
second to segment 2, and so on.
Tol_dirty_nozzle and tol_leaky_nozzle are currently not
used.
An empty list indicates an error.
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 182 of 236 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
For a detailed description of the data item see 4.2
Data Item Dictionary.
2312007 SV L SEGMENTINFOREV3
Summation of information per segment
/
/
,&RPS3LFNHG8S!
,3LFN8S(UURUV!
,&RPS3ODFHG!
,3ODFH(UURUV!
!

!
The first element in this list refers to segment 1, the
second to segment 2, and so on.
The variable can be linked e.g. to event PCBReady. It
is reseted when a PCB reaches the center conveyor.
For a detailed description of the data item see 4.2
Data Item Dictionary.
2312008 SV L PLACEINFOREV3SUB1
Subset of PLACEINFOREVx variable. Detailed
description see there.
/
/
8;SRVLWLRQ!>PP@
8<SRVLWLRQ!>PP@
)$QJOH!>GHJUHHV@
8)RUFH,QGH[!
$5HIHUHQFH'HVLJQDWRU!
$&RPSRQHQW1DPH!
83DFNDJH)RUP1XPEHU!
83ODFHPHQW5HVXOW!
,3ODFHPHQW9DFXXP!>PEDU@
8'DWD9DOLG!
,;GHYLDWLRQ!>PP@
,<GHYLDWLRQ!>PP@
)$QJOH!>GHJUHHV@
)0D[/HDG'HY!