SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 58 of 236 ©Siemens AG, all rights reserved
$6(5 - Alarm serial number
Format: U4
used in: S5F71
$67$7 - Alarm status
Format: Boolean
used in: S5F71, S5F73
&((' - Collection event enable/disable code
Format: B[1]
False = Disable
True = Enable
&(,' - Collection event ID
Format: U4
used in: S2F35, S2F37, S6F3, S6F9, S6F11, S6F13, S6F15, S6F16, S6F17, S6F18
&/2&. - Clock YYYYMMDDhhmsscc
Format A[16]
used in: S5F71, S5F73, CLOCK, PICKUPDATARESETPOINT
FORVHGBQR]]OH Vacuum value for a nozzle
vacuum value measured with closed nozzle
Format: I4
Units are mbar
used in : VACUUMDATAREVx
&0'$ - Command acknowledge code
Format: B[1]
0 = completed or done
1 = command does not exist
2 = cannot perform now
>2 = other equipment specific error
3- 63 reserved
used in: S2F22, S2F28
&RPS/HIW3ODFH Number of components which were not placed on the actual PCB
Format: I2
used in : GANTRYINFOx
&RPS3LFNHG8S Number of components which were picked up successfully per
Gantry or Segment since the current PCB reached the center
conveyor.
Format: I2
used in : GANTRYINFOx, SEGMENTINFOREVx

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 59 of 236
&RPS3ODFHG Number of components which were placed per gantry or segment
since the current PCB reached the center conveyor.
Format:I2
used in : GANTRYINFOx, SEGMENTINFOREVx
&RPSRQHQW1DPH - Name of a component
Format: A
used in: PLACEINFOREVx, PICKUPINFOREVx
&RSODQDULW\(UURUV
1RWXVHG
This value is part of PICKUPERRORSLOCx to be compliant to previous versions
Format: U2
&3$&. - Command Parameter Acknowledge Code
Format: B[1]
1 = Parameter Name does not exist
2 = Illegal value specified for CPVAL
3 = Illegal format specified for CPVAL
4 = PP not in library
>4 = other equipment specific error
4- 63 reserved
used in: S2F22, S2F28
&31$0( - Command Parameter Name
Format: A
used in: S2F41, S2F42
&39$/ - Command Parameter Value
Format:
used in: S2F41
FXELFBQR]]OH Vacuum value for a nozzle
threshold for cubic components
Format: I4
Units are mbar
used in : VACUUMDATEREVx
'$7$,' - Data ID
Format:
used in: S2F33, S2F35, S2F39, S2F49, S6F3, S6F5, S6F9, S6F11, S6F13, S6F13,
S6F16, S6F18
'$7$/(1*7+ - Data Length
Format: U4
used in: S2F39, S6F5

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 60 of 236 ©Siemens AG, all rights reserved
'DWD9DOLG
The fields following the item „DataValid“ represent the result of optical centering. All fields
are not necessarily valid for all package forms. Verify the validity of a field using the
„DataValid“ byte and refer to the corresponding flag for the appropriate field.
If a bit is equal '1' the corresponding field is valid.
Bit 1 X-dev, Y-dev. and angle
Bit 2 Length and Width
Bit 3 lead count
Bit 4 Pitch
Bit 5 Orthogonal deviation
Bit 6 max. lead deviation
Bit 7 max. ball deviation
([DPSOH
Data Valid = 39 (decimal) corresponds to a binary value of 0100111. This means
'X-dev, Y-dev. and angle', 'Length and Width', 'lead count' and 'max. lead deviation'
are valid.
Format: U2
Used in PLACEINFOREVx, PLACEINFOREVxSUB1
'LYLVLRQ - Division at a feeder or the smallest partition in the tray of a Matrix Tray
Changer
Format: I2
used in: PICKUPINFOx
'5$&. - Define Report Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. Insufficient space
2 = Denied. Invalid format
3 = Denied. At least one RPTID already defined
4 = Denied. At least one VID does not exist
>4 = Other errors
5 - 63 reserved
used in: S2F34
'63(5 Data Sample Period
Format: A
used in: S2F23
($& - Equipment Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. At least one constant does not exist