SIPLACE GEM for S25, HS50 SW Version GEM 502.01 HOST Inter face Manual Page 60 of 236 ©Siem ens AG, all rights reser ved 'DWD9DOLG The f ields fo llowing the item „ DataValid “ represent the r esult of optical cente…

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 59 of 236
&RPS3ODFHG Number of components which were placed per gantry or segment
since the current PCB reached the center conveyor.
Format:I2
used in : GANTRYINFOx, SEGMENTINFOREVx
&RPSRQHQW1DPH - Name of a component
Format: A
used in: PLACEINFOREVx, PICKUPINFOREVx
&RSODQDULW\(UURUV
1RWXVHG
This value is part of PICKUPERRORSLOCx to be compliant to previous versions
Format: U2
&3$&. - Command Parameter Acknowledge Code
Format: B[1]
1 = Parameter Name does not exist
2 = Illegal value specified for CPVAL
3 = Illegal format specified for CPVAL
4 = PP not in library
>4 = other equipment specific error
4- 63 reserved
used in: S2F22, S2F28
&31$0( - Command Parameter Name
Format: A
used in: S2F41, S2F42
&39$/ - Command Parameter Value
Format:
used in: S2F41
FXELFBQR]]OH Vacuum value for a nozzle
threshold for cubic components
Format: I4
Units are mbar
used in : VACUUMDATEREVx
'$7$,' - Data ID
Format:
used in: S2F33, S2F35, S2F39, S2F49, S6F3, S6F5, S6F9, S6F11, S6F13, S6F13,
S6F16, S6F18
'$7$/(1*7+ - Data Length
Format: U4
used in: S2F39, S6F5

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 60 of 236 ©Siemens AG, all rights reserved
'DWD9DOLG
The fields following the item „DataValid“ represent the result of optical centering. All fields
are not necessarily valid for all package forms. Verify the validity of a field using the
„DataValid“ byte and refer to the corresponding flag for the appropriate field.
If a bit is equal '1' the corresponding field is valid.
Bit 1 X-dev, Y-dev. and angle
Bit 2 Length and Width
Bit 3 lead count
Bit 4 Pitch
Bit 5 Orthogonal deviation
Bit 6 max. lead deviation
Bit 7 max. ball deviation
([DPSOH
Data Valid = 39 (decimal) corresponds to a binary value of 0100111. This means
'X-dev, Y-dev. and angle', 'Length and Width', 'lead count' and 'max. lead deviation'
are valid.
Format: U2
Used in PLACEINFOREVx, PLACEINFOREVxSUB1
'LYLVLRQ - Division at a feeder or the smallest partition in the tray of a Matrix Tray
Changer
Format: I2
used in: PICKUPINFOx
'5$&. - Define Report Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. Insufficient space
2 = Denied. Invalid format
3 = Denied. At least one RPTID already defined
4 = Denied. At least one VID does not exist
>4 = Other errors
5 - 63 reserved
used in: S2F34
'63(5 Data Sample Period
Format: A
used in: S2F23
($& - Equipment Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. At least one constant does not exist

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 61 of 236
2 = Denied. Busy
3 = Denied. At least one constant out of range
>3 = Other errors
4 - 63 reserved
used in: S2F16
(&'() - Equipment Constant Default Value
Format:
used in: S2F30
(&0$; - Equipment Constant MaximumValue
Format:
used in: S2F30
(&0,1 - Equipment Constant Minimum Value
Format:
used in: S2F30
(&1$0( - Equipment Constant Name
Format:
used in: S2F30
(5$&. - Enable/Disable Event Report
Format: B[1]
0 = Accept
1 = Denied. At least one CEID does not exist
>1 = Other errors
2 - 63 reserved
used in: S2F38
)&1,' - Function Identification
Format: U1
used in: S2F43, S2F44
)HHGHU$FFHVVHV3HU3&%– Number of feeder accesses per PCB
Format: U2
used in: PICKUPERRORSLOCx
)HHGHU7\SHIdentifier for a feeder
Format: U2
1 Linear 4.5 mm
2 Linear 9.5 mm
3 Linear 10 mm
4 Linear 14 mm
5 Linear 30 mm
6 0402_0603
7 8 mm tape, electric, 2 x cycle
8 8 mm tape, electric
9 8 mm tape, mechanical, 2 x cycle
10 8 mm tape, mechanical
11 12mm tape "long"
12 16mm tape "long"