00192375-01 - 第61页

SIPLACE GEM for S25, HS50 SW Version GEM 502.01 HOST Inter face Manual ©Siemens AG, all rights reserved page 61 of 236 2 = Denied. Busy 3 = Denied. At least one constant out of range >3 = Other errors 4 - 63 r eserved…

100%1 / 236
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 60 of 236 ©Siemens AG, all rights reserved
'DWD9DOLG
The fields following the item DataValid represent the result of optical centering. All fields
are not necessarily valid for all package forms. Verify the validity of a field using the
DataValid byte and refer to the corresponding flag for the appropriate field.
If a bit is equal '1' the corresponding field is valid.
Bit 1 X-dev, Y-dev. and angle
Bit 2 Length and Width
Bit 3 lead count
Bit 4 Pitch
Bit 5 Orthogonal deviation
Bit 6 max. lead deviation
Bit 7 max. ball deviation
([DPSOH
Data Valid = 39 (decimal) corresponds to a binary value of 0100111. This means
'X-dev, Y-dev. and angle', 'Length and Width', 'lead count' and 'max. lead deviation'
are valid.
Format: U2
Used in PLACEINFOREVx, PLACEINFOREVxSUB1
'LYLVLRQ - Division at a feeder or the smallest partition in the tray of a Matrix Tray
Changer
Format: I2
used in: PICKUPINFOx
'5$&. - Define Report Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. Insufficient space
2 = Denied. Invalid format
3 = Denied. At least one RPTID already defined
4 = Denied. At least one VID does not exist
>4 = Other errors
5 - 63 reserved
used in: S2F34
'63(5 Data Sample Period
Format: A
used in: S2F23
($& - Equipment Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. At least one constant does not exist
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 61 of 236
2 = Denied. Busy
3 = Denied. At least one constant out of range
>3 = Other errors
4 - 63 reserved
used in: S2F16
(&'() - Equipment Constant Default Value
Format:
used in: S2F30
(&0$; - Equipment Constant MaximumValue
Format:
used in: S2F30
(&0,1 - Equipment Constant Minimum Value
Format:
used in: S2F30
(&1$0( - Equipment Constant Name
Format:
used in: S2F30
(5$&. - Enable/Disable Event Report
Format: B[1]
0 = Accept
1 = Denied. At least one CEID does not exist
>1 = Other errors
2 - 63 reserved
used in: S2F38
)&1,' - Function Identification
Format: U1
used in: S2F43, S2F44
)HHGHU$FFHVVHV3HU3&% Number of feeder accesses per PCB
Format: U2
used in: PICKUPERRORSLOCx
)HHGHU7\SHIdentifier for a feeder
Format: U2
1 Linear 4.5 mm
2 Linear 9.5 mm
3 Linear 10 mm
4 Linear 14 mm
5 Linear 30 mm
6 0402_0603
7 8 mm tape, electric, 2 x cycle
8 8 mm tape, electric
9 8 mm tape, mechanical, 2 x cycle
10 8 mm tape, mechanical
11 12mm tape "long"
12 16mm tape "long"
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 62 of 236 ©Siemens AG, all rights reserved
14 24mm "Blister" tape
15 32mm "Paper" tape
16 32mm "Blister" tape
17 44mm tape
18 56mm tape
19 8mm tape "long" 4mm manual
29 8mm tape "long" 2mm manual
30 waffle-pack tray, Matrix Tray Changer
56 24mm type III
57 32mm type III
58 44mm type III
59 56mm type III
60 S_G_12_S
61 S_G_16_S
62 S_G_24_S
63 S_G_32_S
64 S_G_44_S
65 S_G_56_S
66 72mm-S tape
79 3x8 mm tape
80 8mm Surftape feeder
81 12mm Surftape feeder
82 24mm Surftape feeder
149 8mm tape long 8mm
150 8mm "Schulz" tape
151 Fimecore
152 Nitto
153 Bulk-Case feeder
used in: PICKUPINFOREVx
)LGXFLDO1DPHIdentifier of a fiduvial
Format: U2
used in: FIDUCIALDATA
)LOOLQJBOHYHO - Number of components in a division of a matrix tray changer
Format: I4
used in: MTCInfo
)RUFH,QGH[ - programmed placement force
see chapter 3.5 in the SIPLACE Data Interface for a detailed description.
Format: U1
used in: PLACEINFOREVx
*$175<*5283,' ID of the gantry-group
Format: U2
1 = First gantrygroup in direction of transport
2 = Second gantrygroup in direction of transport
*$175<,' ID of the gantry
Format: U2
1...4 (see charpter 'Machine Areas')