00192375-01 - 第63页

SIPLACE GEM for S25, HS50 SW Version GEM 502.01 HOST Inter face Manual ©Siemens AG, all rights reserved page 63 of 236 *5$ 17 - Perm iss ion to send Form at: B[1] 0 = Perm ission gr anted 1 = Busy, try again 2 = Not int…

100%1 / 236
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 62 of 236 ©Siemens AG, all rights reserved
14 24mm "Blister" tape
15 32mm "Paper" tape
16 32mm "Blister" tape
17 44mm tape
18 56mm tape
19 8mm tape "long" 4mm manual
29 8mm tape "long" 2mm manual
30 waffle-pack tray, Matrix Tray Changer
56 24mm type III
57 32mm type III
58 44mm type III
59 56mm type III
60 S_G_12_S
61 S_G_16_S
62 S_G_24_S
63 S_G_32_S
64 S_G_44_S
65 S_G_56_S
66 72mm-S tape
79 3x8 mm tape
80 8mm Surftape feeder
81 12mm Surftape feeder
82 24mm Surftape feeder
149 8mm tape long 8mm
150 8mm "Schulz" tape
151 Fimecore
152 Nitto
153 Bulk-Case feeder
used in: PICKUPINFOREVx
)LGXFLDO1DPHIdentifier of a fiduvial
Format: U2
used in: FIDUCIALDATA
)LOOLQJBOHYHO - Number of components in a division of a matrix tray changer
Format: I4
used in: MTCInfo
)RUFH,QGH[ - programmed placement force
see chapter 3.5 in the SIPLACE Data Interface for a detailed description.
Format: U1
used in: PLACEINFOREVx
*$175<*5283,' ID of the gantry-group
Format: U2
1 = First gantrygroup in direction of transport
2 = Second gantrygroup in direction of transport
*$175<,' ID of the gantry
Format: U2
1...4 (see charpter 'Machine Areas')
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 63 of 236
*5$17 - Permission to send
Format: B[1]
0 = Permission granted
1 = Busy, try again
2 = Not interested
>2 = Other errors
3 - 63 reserved
used in: S6F6
+&$&. - Host Command Parameter Acknowledge Code
Format: B[1]
0 = Accept, Command has been performed
1 = Command does not exist
2 = Cannot perform now
3 = At least one parameter is invalid
4 = Acknowledge, command will be performed with completion signaled later by an
event
5 = Rejected. Already in desired condition
6 = control state is not remote
7 = recipe not in library
8 = control mode is not GEM-Host
9 = bad PP-Body
10 - 63 reserved
used in: S2F42
+($',' ID of the head within a gantry
Format: U2
In this version there is only 1 head per gantry. HEADID is always = 1.
+(,*+72)5(92/9(5 distance between the head and the transport conveyor
During the reference run, the SIPLACE machines measures the difference between the
upper edge of the transport conveyor and the nozzle on segment 1. The
HEIGHTREVOLVER is then calculated by subtracting the length of the nozzle on segment
1 form the measured value. The nozzle length is defined in the machine data. So
HEIGHTREVOLOR is a relative, not an absolute value.
Format:I4
Units are 1/1000 mm
used in : HEIGHTREVOLVERx
/HDG&RXQW - Number of lead found during package form measurement
Format: U2
used in: PLACEINFOREVx
/HQJWK- Length of a package form
Length is returned from the vision system. Its the optical length of the package form.
Units are 1/1000 mm
Format: U4
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 64 of 236 ©Siemens AG, all rights reserved
used in: PLACEINFOREVx
/HYHO- Level in the matrix tray changer
Level 1 is the lowest level in matrix tray changer, level 40 the top most. A value of 0
indicates the manual tray.
Format: I2
used in: PICKUPINFOREVx
/,0,7$&. - Acknowledgment code for variable limit attribute set
Format: B[1]
1 = LIMITID does not exist
2 = UPPERDB < LIMITMAX
3 = LOWERDB >LIMITMIN
4 = UPPERDB < LOWERDB
5 = Illegal format specified for UPPERDB or LOWERDB
6 = ASCII value cannot be translated to numeric
7 = Duplicate limit definition for this variable
>7 = Other errors
8 - 63 reserved
used in: S2F46
/,0,7,' - Limit ID
Format: B[1]
used in: S2F45, S2F46, S2F48
/,0,70$; - maximum limit
Format:
used in: S2F48
/,0,70,1 - minimum limit
Format:
used in: S2F48
/2&$7,21*URXSRIIHHGHUV
For a detailed description see 1.6 Machine Areas"
Used in LOCATION, PICKINFOREVx, PICKUPERRORSLOCx, TRACKFULL,
TRACKEMPTY
/2:(5'% - lower boundary of the deadband for a limit
Format
used in: S2F45, S2F48
/5$&. - Limit Report Acknowledge Code
Format: B[1]
0 = Accepted
1 = Denied. Insufficient space
2 = Denied. Invalid format