SIPLACE GEM for S25, HS50 SW Version GEM 502.01 HOST Inter face Manual Page 64 of 236 ©Siem ens AG, all rights reser ved used in: PLACEINFOREVx /HYHO - Level in the matr ix tray changer Level 1 is the lowest level in m …

100%1 / 236
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 63 of 236
*5$17 - Permission to send
Format: B[1]
0 = Permission granted
1 = Busy, try again
2 = Not interested
>2 = Other errors
3 - 63 reserved
used in: S6F6
+&$&. - Host Command Parameter Acknowledge Code
Format: B[1]
0 = Accept, Command has been performed
1 = Command does not exist
2 = Cannot perform now
3 = At least one parameter is invalid
4 = Acknowledge, command will be performed with completion signaled later by an
event
5 = Rejected. Already in desired condition
6 = control state is not remote
7 = recipe not in library
8 = control mode is not GEM-Host
9 = bad PP-Body
10 - 63 reserved
used in: S2F42
+($',' ID of the head within a gantry
Format: U2
In this version there is only 1 head per gantry. HEADID is always = 1.
+(,*+72)5(92/9(5 distance between the head and the transport conveyor
During the reference run, the SIPLACE machines measures the difference between the
upper edge of the transport conveyor and the nozzle on segment 1. The
HEIGHTREVOLVER is then calculated by subtracting the length of the nozzle on segment
1 form the measured value. The nozzle length is defined in the machine data. So
HEIGHTREVOLOR is a relative, not an absolute value.
Format:I4
Units are 1/1000 mm
used in : HEIGHTREVOLVERx
/HDG&RXQW - Number of lead found during package form measurement
Format: U2
used in: PLACEINFOREVx
/HQJWK- Length of a package form
Length is returned from the vision system. Its the optical length of the package form.
Units are 1/1000 mm
Format: U4
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 64 of 236 ©Siemens AG, all rights reserved
used in: PLACEINFOREVx
/HYHO- Level in the matrix tray changer
Level 1 is the lowest level in matrix tray changer, level 40 the top most. A value of 0
indicates the manual tray.
Format: I2
used in: PICKUPINFOREVx
/,0,7$&. - Acknowledgment code for variable limit attribute set
Format: B[1]
1 = LIMITID does not exist
2 = UPPERDB < LIMITMAX
3 = LOWERDB >LIMITMIN
4 = UPPERDB < LOWERDB
5 = Illegal format specified for UPPERDB or LOWERDB
6 = ASCII value cannot be translated to numeric
7 = Duplicate limit definition for this variable
>7 = Other errors
8 - 63 reserved
used in: S2F46
/,0,7,' - Limit ID
Format: B[1]
used in: S2F45, S2F46, S2F48
/,0,70$; - maximum limit
Format:
used in: S2F48
/,0,70,1 - minimum limit
Format:
used in: S2F48
/2&$7,21*URXSRIIHHGHUV
For a detailed description see 1.6 Machine Areas"
Used in LOCATION, PICKINFOREVx, PICKUPERRORSLOCx, TRACKFULL,
TRACKEMPTY
/2:(5'% - lower boundary of the deadband for a limit
Format
used in: S2F45, S2F48
/5$&. - Limit Report Acknowledge Code
Format: B[1]
0 = Accepted
1 = Denied. Insufficient space
2 = Denied. Invalid format
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 65 of 236
3 = Denied. At least one CEID link already defined
4 = Denied. At least one CEID does not exist
5 = Denied. At least one RPTID does not exist
>5 = Other errors
6 - 63 reserved
used in: S2F36
/9$&. - Variable limit definition acknowledge code
Format: B[1]
1 = Variable does not exist
2 = Variable has no limits capability
3 = Variable repeated in message
4 = Limit value error as desired in LIMITACK
5 - 63 reserved
used in: S2F46
0DFKLQH6LGH - Side of the machine
Format: U1
0 = right side in transport direction
1 = left side in transport direction
0D[%DOO'HY - Maximal ball deviation
MaxBallDev is calculated by the vision system during the optical centering of a package
form. It is calculated over all balls in all ball groups.
Format: F8
Units are 1/1000 mm
used in: PLACEINFOREVx,
0D[/HDG'HY - Maximum lead deviation
MaxLeadDev is calculate by the vision system during the optical centering of a package
form. It is calculate over all leads in all lead groups.
Format: F8
Units are 1/1000 mm
used in: PLACEINFOREVx,
0'/1 - Equipment Model Type
Format: A
used in: S1F2, S1F13, S1F14, S1F65, S1F66
0+($' - Message block header associated with block in error
Format: B[16]
used in: S9F1, S9F3, S9F5, S9F7, S9F11
0,' - Lot ID
Format: A[16]
used in S2F27